Impecca IWA06-KR15 Скачать руководство пользователя страница 2

Read the following notices and information carefully to ensure proper operation of your air 

conditioner unit.

This manual is solely provided for informational purposes and in no way constitutes a legally 

binding document between the manufacturer, distributor, and end consumer. Exact appear-

ance of your unit may differ from the pictures and diagrams enclosed. 

Lea las siguientes indicaciones cuidadosamente para asegurar el correcto funcionamiento 

de su unidad de aire acondicionado. 

Este manual se proporciona únicamente con fines informativos y de ninguna manera 

constituye un documento jurídicamente vinculante entre el fabricante, distribuidor y 

consumidor final. Apariencia exacta de su unidad puede diferir de las imágenes y esque-

mas adjuntos.

WARNING:

To avoid permanent damage to unit:

Ensure it is in the upright position for a MINIMUM of 6 

hours and a RECOMMENDED time of 24 hours before pow-

ering on the first time.

ADVERTENCIA

Para evitar daños permanentes a la 

unidad:

Asegúrese de que está en la posición vertical durante

un mínimo de 6 horas y un tiempo recomendado de 24 

horas antes de encender la primera vez.

Spanish version of this manual available for download on 

www.impecca.com

Содержание IWA06-KR15

Страница 1: ...ElectronicWindowAirConditionerwithRemote User sGuide Models IWA06 KR15 IWA08 KR15 IWA10 KR15 IWA12 KR15 IWA06 KS30 IWA08 KS30 IWA10_KS30 IWA12 KS30 Energy Star www impecca com v1 3...

Страница 2: ...proporciona nicamente con fines informativos y de ninguna manera constituye un documento jur dicamente vinculante entre el fabricante distribuidor y consumidor final Apariencia exacta de su unidad pu...

Страница 3: ...ioner 7 Delay Start Stop Timer 11 Installation Instructions 14 R1 Insulation Installation for some models 16 Cleaning Maintenance 18 Troubleshooting 19 Electrical Information 21 Customer Support 21 On...

Страница 4: ...repair It may cause fire and electric shock It may cause electric shock Ensure the power cord is kept away from any heating sources Do not disassemble or modify unit Do not use the power cord near fla...

Страница 5: ...damage personal injury or death Operation with dirty filters or without filters will effect performance and may cause damage to the unit Do not use strong detergent such as wax or paint thinner to cl...

Страница 6: ...vy objects Do not pull or yank the power cord to unplug the unit or move the air conditioner Do not insert or unplug the power plug with wet hands Only use a grounded power outlet Make sure the ground...

Страница 7: ...oner If there s problem please disconnect the power supply immediately and contact your local dealer or technical support GETTINGTOKNOWYOURAIRCONDITIONER 1 Upperrail 2 Coolairoutlet 3 Coolairdirection...

Страница 8: ...Air Ionization On Some models 5 Function selector Auto Cool Dry Fan 6 Energy Saver 7 Temperature Timer Up 8 Display Temperature Timer 9 Sleep mode 10 Fan Speed selector 11 Infrared Remote senor window...

Страница 9: ...selected USING AUTO FEATURE When you set the air conditioner in AUTO mode it will automatically select cooling or fan only operation de pending on the current room temperature and the target temperat...

Страница 10: ...f if you want the fan to run constantly during cooling mode SLEEP MODE In this mode the selected temperature will increase by 2 F or 2 C 30 minutes after the mode is selected The tempera ture will the...

Страница 11: ...onditioner s display shows the last Auto Off setting if any Now you are ready to reset the Auto Off time to START the operation 2 Press either the or buttons to set desired Auto Off time Each time you...

Страница 12: ...conditioning unit 2 Flexible window filler panels 3 Upper Rail may already be attached 4 Upper Rail seal may already be at tached to bottom of rail 5 Foam sash seal no adhesive 6 Foam seal with adhesi...

Страница 13: ...and may cause water condensation to enter the room interior Perform these modifications to ensure proper operation of your unit If you have a standard window skip this step 1 Cut a 2 thick piece of w...

Страница 14: ...Fig A 2 Use the 4 screws included to attach the upper rail to the pre drilled holes on the top of the cabinet as shown in Figure B Ensure that the higher part of the rail is facing the front of the ai...

Страница 15: ...ld be completely flush with the windowsill Gently lower the window until it holds the upper rail in place The chassis and frames are configured to allow for a natural pitch towards the outside of abou...

Страница 16: ...w and the closed upper window by placing the non adhesive foam sash seal in between the window sash and the glass pane R1 INSULATION INSTALLATION FOR SOME MODELS R1 is the name given to special additi...

Страница 17: ...in the window measure the width of each side s exposed filler panel as shown in the diagram 2 Cut the insulation panel to size for each side of the side curtain 3 Slide the R1 panel into place 1 2 3 4...

Страница 18: ...sing your air conditioner in the warm summer months always perform the fol lowing verifications Disconnect the unit electrical power Clean the filter and unit casing Remove dust and other objects on t...

Страница 19: ...scrub the filter in a bath of warm not hot soapy water Let the filter completely dry in a shady place exposing the filter to direct sunlight can cause deformation After the filter is clean and comple...

Страница 20: ...y be caused by residue from cooking and cigarette smoke etc that remain in the air conditioning unit Eliminated the source of the smell and clean the filter THE UNIT MAKES LOUD OR UNUSUAL NOISES AND V...

Страница 21: ...ult to access this serial number later Model number __________________ One of the numbers mentioned on the cover of this manual Your exact number is found on your box or on the rating label sticker on...

Страница 22: ...rvice calls for a product ruined by not following the pro vided instructions 10 Service calls to correct improper installation 11 Costs associated with making the product accessible for ser vicing inc...

Страница 23: ...to 9 Llamadas de servicio de un producto estropeado por no seguirlasinstruccionesproporcionadas 10 Llamadas de servicio para corregir una instalaci n inco rrecta 11 Costos asociados por hacer el produ...

Страница 24: ...ppelsdeservicequinesontpasenlienavecunmal fonctionnementdel appareil 9 Appelsdeservicepourunappareilendommag suiteau non respectdesinstructionsfournies 10 Appelsdeserviceli s uneinstallationd fectueus...

Отзывы: