background image

SAFETY INFORMATION

Warning!

This compressor must be connected

to a power socket that is safeguarded by a
suitable circuit breaker or fuse.

Only use recommended parts. To avoid the risk
of bursting, only hoses with a rated pressure of
8 bar, or more should be used. Never attempt to
repair faulty hoses.

Avoid kinking or trapping the air hose. Always
replace faulty hoses - never attempt a repair if a
leak is detected.

Drain the tank after each use. Switch off and
sowly open the drain valve to release the air
then tilt the compressor to empty condensed
water.

Keep the motor vent clear and free from dust,
wipe regularly to maintain an adequate supply of
clean air to the air compressor.

General Safety Rules
Warning!

Read all instructions Failure to follow

all instructions listed below may result in electric
shock, fire and/or serious injury. The term
"power tool" in all of the warnings listed below
refers to your mains operated (corded) power
tool or battery operated (cordless) power tool.

Save These Instructions

1) Work Area

a)

Keep work area clean and well lit.

Cluttered and dark areas invite accidents.

b)

Do not operate power tools in explosive
atmospheres, such as in the presence of
flammable liquids, gases or dust.

Power

tools create sparks which may ignite the dust
or fumes.

c)

Keep children and bystanders away while
operating a power tool.

Distractions can

cause you to lose control.

2) Electrical Safety

a)

Power tool plugs must match the outlet.
Never modify the plug in any way. Do not
use any adapter plugs with earthed
(grounded) power tools.

Unmodified plugs

and matching outlets will reduce risk of
electric shock.

b)

Avoid body contact with earthed or
grounded surfaces such as pipes,
radiators, ranges and refrigerators.

There is an increased risk of electric shock if
your body is earthed or grounded.

c)

Do not expose power tools to rain or wet
conditions.

Water entering a power tool will

increase the risk of electric shock.

d)

Do not abuse the cord. Never use the cord
for carrying, pulling or unplugging the
power tool. Keep cord away from heat, oil,
sharp edges or moving parts.

Damaged or

entangled cords increase the risk of electric
shock.

e)

When operating a power tool outdoors,
use an extension cord suitable for outdoor
use.

Use of a cord suitable for outdoor use

reduces the risk of electric shock.

3) Personal Safety

a)

Stay alert, watch what you are doing and
use common sense when operating a
power tool. Do not use a power tool while
you are tired or under the influence of
drugs, alcohol or medication.

A moment of inattention while operating
power tools may result in serious personal
injury.

b)

Use safety equipment. Always wear eye
protection.

Safety equipment such as dust

mask, non-skid safety shoes, hard hat, or
hearing protection used for appropriate
conditions will reduce personal injuries.

c)

Avoid accidental starting. Ensure the
switch is in the off position before
plugging in.

Carrying power tools with your

finger on the switch or plugging in power
tools that have the switch on invites
accidents.

d)

Remove any adjusting key or wrench
before turning the power tool on.

A wrench or a key left attached to a rotating
part of the power tool may result in personal
injury.

4

Содержание IM412-24L

Страница 1: ...ND ADDRESS OF TECHNICAL DOCUMENTATION HOLDER 4HE TECHNICAL DOCUMENTATION REQUIRED TO DEMONSTRATE THAT THE PRODUCT MEETS THE REQUIREMENTS OF DIRECTIVE HAS BEEN COMPILED AND IS AVAILABLE FOR INSPECTION BY THE RELEVANT ENFORCEMENT AUTHORITIES 3IGNED 0RINT ARK 3HANNON 1UALITY IRECTOR 0 RANDS TD APIER OUSE 5NIT ORUNNA OURT 7ARWICK 5NITED INGDOM 6 1 ATE 4HE ACHINERY IRECTIVE OW 6OLTAGE QUIPMENT IRECTIVE...

Страница 2: ...Always Read Instruction Manual Retain for Future Reference IM412 24L 24L HIGH FLOW AIR COMPRESSOR ...

Страница 3: ... adequately packed to prevent transit damage and must be accompanied with a brief description of the fault and a copy of the receipt or other proof of purchase The manufacturer shall not be liable for any special exemplary direct indirect incidental or consequential loss or damage under this guarantee This guarantee is in addition to and does not affect any rights which the consumer may have by vi...

Страница 4: ...d air can be potentially dangerous when not used correctly Do not exceed the maximum rated air pressure for the accessory Do not direct compressed air at yourself any other person or animals Do not direct any liquid or any other material that is being sprayed by yourself towards any other person or animals Only use hoses and connectors designed for use with compressed air The maximum working press...

Страница 5: ...ny adapter plugs with earthed grounded power tools Unmodified plugs and matching outlets will reduce risk of electric shock b Avoid body contact with earthed or grounded surfaces such as pipes radiators ranges and refrigerators There is an increased risk of electric shock if your body is earthed or grounded c Do not expose power tools to rain or wet conditions Water entering a power tool will incr...

Страница 6: ...asures reduce the risk of starting the power tool accidentally d Store idle power tools out of the reach of children and do not allow persons unfamiliar with the power tool or these instructions to operate the power tool Power tools are dangerous in the hands of untrained users e Maintain power tools Check for misalignment or binding of moving parts breakage of parts and any other condition that m...

Страница 7: ...o the terminal marked Earth E Ensure that the outer insulation is gripped by the cord grip and that the wires are not trapped when replacing the plug cover The mains lead on this product is fitted with a 13 amp BS1363 A plug A 13 amp BS1362 fuse must be fitted in the plug If In Doubt Consult A Qualified Electrician There are no user serviceable parts inside except those referred to in the manual A...

Страница 8: ...K RELEASE CONNECTOR REGULATED IR OUTLET PRESSURE GAUGE IR RECEIVER PRESSURE GAUGE 2ESET BUTTON IL FILL CAP 2UBBER FOOT IR RECEIVER TANK RAIN VALVE 0OWER LEAD 4ECHNICAL SPECIFICATION 6OLTAGE 6 Z 2ATED POWER 0 2ECEIVER CAPACITY 4YPE IL LUBRICATED REE AIR DELIVERY MIN IL TYPE AND CAPACITY 3 ML 7ORKING PRESSURE AR PSI O LOAD SPEED MIN 7EIGHT KG 3OUND POWER LEVEL D ...

Страница 9: ... CARE WHEN LIFTING THE COMPRESSOR FROM THE PACKAGING AUTION O NOT LIFT THE COMPRESSOR BY THE PRESSURE REGULATOR ET ASSISTANCE IF NECESSARY 4HIS UNIT WEIGHS KG SSEMBLY ITTING THE 7HEELS NSERT A SPLIT PIN INTO THE INNER HOLE ON THE TRANSPORTATION FRAME AND THEN INSERT A WASHER IG NSERT THE WHEEL WITH THE AIR VALVE POINTING OUT FROM THE COMPRESSOR AND THEN LOCK INTO PLACE WITH A WASHER AND SPLIT PIN ...

Страница 10: ...ressor oil such as SAE 30 non detergent API CG CD Heavy Duty oil at slow intervals until the oil reaches the center of the red circle in the sight glass Fig 6 Use SAE 10 during extreme winter conditions Locating the Air Compressor This compressor should be positioned on a stable flat surface or one with a maximum inclination of 15º Ensure that it is completely stable Do not cover or box in the com...

Страница 11: ...f 8 5 Bar is exceeded should the pressure switch fail Overload Protection This compressor is fitted with an overload protection device In the event that the motor becomes too hot a thermal protection device will cut the mains supply to the motor When the motor temperature returns to normal the mains supply will be restored automatically Preparing For Use Before connecting your compressor to the ma...

Страница 12: ...air receiver tank supply tube will become hot Connecting Hoses Accessories Warning Do not operate accessories at an air pressure greater than the maximum rated air pressure for the accessory Connect a hose to the compressor using the hose to compressor quick release connector Fig 11 When using the regulated air output first determine the working pressure of the accessory by referring to the access...

Страница 13: ... and stop when the ring is released If the valve does not operate as described or if the valve is stuck it must be replaced by qualified service personnel before using the compressor Warning Do not remove or attempt to adjust the safety valve Reset Button This compressor is equipped with a thermal overload device which operates as a safety device to protect the motor When the motor overheats for a...

Страница 14: ...the sight glass When re assembling Be sure the gasket is between the sight glass and the pump crankcase 8 Refill the compressor pump with an air compressor oil such as SAE 30 non detergent API CG CD Heavy Duty oil at slow intervals until the oil reaches the center of the red circle in the sight glass Use a SAE 10 during extreme winter conditions Maintenance Important Before carrying out any mainte...

Страница 15: ...dicates that used and end of life electrical and electronic equipment should not be disposed of in household waste For the proper disposal treatment recovery and recycling please take these products to designated collection points where they will be accepted on a free of charge basis Alternatively in some countries you may be able to return your products to your retailer upon the purchase of an eq...

Страница 16: ...requirements Waste electrical products should not be disposed of with household waste Please recycle where facilities exist Check with your Local Authority or retailer for recycling advice General warning Wear hearing protection Wear eye protection Wear respiratory protection CAUTION Hot surface Risk of electric shock The compressor must be disconnected from the mains supply before removing any co...

Отзывы: