background image

3

SAFETY INFORMATION

Specific Safety Instructions
Warning!

If not used and maintained correctly

this compressor when used with some
pneumatic tools can cause serious injury and
death. Before attempting to operate this
machine, it is important that you read,
understand and follow these instructions very
carefully. They are designed for the safety of
yourself and others ensuring a long and trouble
free service life from your machine. If not used
correctly and as detailed in these instructions
pneumatic tools can be dangerous. This product
can cause injury to the operator and others. The
warnings and safety instructions must be
followed to ensure reasonable safety and
efficiency in using this product.

Note:

The operator is responsible for following

the warnings and safety instructions in this
manual and on the product.

Ensure that this compressor is disconnected
from the mains supply when not in use and the
air receiver fully discharged before servicing,
lubricating or making adjustments and when
changing accessories. Always switch ON and
OFF using the ON/OFF switch on the
compressor before switching OFF at the mains
supply.

Warning!

When spraying paint or cleaning

agents the fine mist produced could ignite.
When performing this type of operation the
compressor must be a minimum of 4 Metres
away from the work area. Do not smoke and
keep naked flames and other sources of ignition
well away from the work area. Make sure that
the area in which you are working has good
ventilation and protect your nose and mouth
with a suitable face mask. Always check the
safety data sheets for substances being sprayed
& ensure manufacturers instructions are
followed.

This air compressor must be used in a suitable
environment. There must be adequate
ventilation, the ambient temperature must be
+5/+40°C. The working area must be free from
dust, acid vapour, explosive gasses and
flammable materials.

Compressed air can be potentially dangerous
when not used correctly. Do not exceed the

maximum rated air pressure for the accessory.
Do not direct compressed air at yourself, any
other person or animals. Do not direct any liquid
or any other material that is being sprayed by
yourself towards any other person or animals.

Only use hoses and connectors designed for
use with compressed air. The maximum working
pressure of hoses and connectors must be
higher than the maximum working pressure of
the compressor. Do not attempt to move the
compressor by pulling on the air hose.

This compressor is designed for tyre inflation,
the operation of pneumatic tools, spray painting
and spraying non-corrosive cleaning agents. Do
not use this compressor for filling cylinders for
breathing or diving apparatus. Compressed air
from this compressor must not be used for
pharmaceutical, food or health applications.

When spraying flammable liquids such as paint
and non-corrosive cleaning agents the distance
between the compressor and the work area
must be a minimum of 4 metres. When spraying
liquids always wear a suitable face mask
designed for protection against the liquid being
sprayed. Always wear approved safety glasses.

Do not attempt to modify the compressor or any
pneumatic tools in any way. Use only
accessories and pneumatic tools that are rated
for the capacity of the compressor. Never leave
the compressor pressurised.

Always transport the compressor by lifting or
pulling it with the appropriate grips or handles.

Do not insert your fingers or other objects inside
the motor housing to avoid physical damage or
damage to the compressor.

If any part of the compressor is damaged, it
should be carefully checked to determine that it
will operate correctly and perform its intended
function. Check for the alignment of parts,
damage to parts, air leaks and any other
conditions that may affect its operation. A guard
or any other part that is damaged or defective
should be properly repaired or replaced by an
authorised service centre. Defective pressure
switches must be replaced prior to further use
of the compressor.

Содержание IM412-24L

Страница 1: ...ND ADDRESS OF TECHNICAL DOCUMENTATION HOLDER 4HE TECHNICAL DOCUMENTATION REQUIRED TO DEMONSTRATE THAT THE PRODUCT MEETS THE REQUIREMENTS OF DIRECTIVE HAS BEEN COMPILED AND IS AVAILABLE FOR INSPECTION BY THE RELEVANT ENFORCEMENT AUTHORITIES 3IGNED 0RINT ARK 3HANNON 1UALITY IRECTOR 0 RANDS TD APIER OUSE 5NIT ORUNNA OURT 7ARWICK 5NITED INGDOM 6 1 ATE 4HE ACHINERY IRECTIVE OW 6OLTAGE QUIPMENT IRECTIVE...

Страница 2: ...Always Read Instruction Manual Retain for Future Reference IM412 24L 24L HIGH FLOW AIR COMPRESSOR ...

Страница 3: ... adequately packed to prevent transit damage and must be accompanied with a brief description of the fault and a copy of the receipt or other proof of purchase The manufacturer shall not be liable for any special exemplary direct indirect incidental or consequential loss or damage under this guarantee This guarantee is in addition to and does not affect any rights which the consumer may have by vi...

Страница 4: ...d air can be potentially dangerous when not used correctly Do not exceed the maximum rated air pressure for the accessory Do not direct compressed air at yourself any other person or animals Do not direct any liquid or any other material that is being sprayed by yourself towards any other person or animals Only use hoses and connectors designed for use with compressed air The maximum working press...

Страница 5: ...ny adapter plugs with earthed grounded power tools Unmodified plugs and matching outlets will reduce risk of electric shock b Avoid body contact with earthed or grounded surfaces such as pipes radiators ranges and refrigerators There is an increased risk of electric shock if your body is earthed or grounded c Do not expose power tools to rain or wet conditions Water entering a power tool will incr...

Страница 6: ...asures reduce the risk of starting the power tool accidentally d Store idle power tools out of the reach of children and do not allow persons unfamiliar with the power tool or these instructions to operate the power tool Power tools are dangerous in the hands of untrained users e Maintain power tools Check for misalignment or binding of moving parts breakage of parts and any other condition that m...

Страница 7: ...o the terminal marked Earth E Ensure that the outer insulation is gripped by the cord grip and that the wires are not trapped when replacing the plug cover The mains lead on this product is fitted with a 13 amp BS1363 A plug A 13 amp BS1362 fuse must be fitted in the plug If In Doubt Consult A Qualified Electrician There are no user serviceable parts inside except those referred to in the manual A...

Страница 8: ...K RELEASE CONNECTOR REGULATED IR OUTLET PRESSURE GAUGE IR RECEIVER PRESSURE GAUGE 2ESET BUTTON IL FILL CAP 2UBBER FOOT IR RECEIVER TANK RAIN VALVE 0OWER LEAD 4ECHNICAL SPECIFICATION 6OLTAGE 6 Z 2ATED POWER 0 2ECEIVER CAPACITY 4YPE IL LUBRICATED REE AIR DELIVERY MIN IL TYPE AND CAPACITY 3 ML 7ORKING PRESSURE AR PSI O LOAD SPEED MIN 7EIGHT KG 3OUND POWER LEVEL D ...

Страница 9: ... CARE WHEN LIFTING THE COMPRESSOR FROM THE PACKAGING AUTION O NOT LIFT THE COMPRESSOR BY THE PRESSURE REGULATOR ET ASSISTANCE IF NECESSARY 4HIS UNIT WEIGHS KG SSEMBLY ITTING THE 7HEELS NSERT A SPLIT PIN INTO THE INNER HOLE ON THE TRANSPORTATION FRAME AND THEN INSERT A WASHER IG NSERT THE WHEEL WITH THE AIR VALVE POINTING OUT FROM THE COMPRESSOR AND THEN LOCK INTO PLACE WITH A WASHER AND SPLIT PIN ...

Страница 10: ...ressor oil such as SAE 30 non detergent API CG CD Heavy Duty oil at slow intervals until the oil reaches the center of the red circle in the sight glass Fig 6 Use SAE 10 during extreme winter conditions Locating the Air Compressor This compressor should be positioned on a stable flat surface or one with a maximum inclination of 15º Ensure that it is completely stable Do not cover or box in the com...

Страница 11: ...f 8 5 Bar is exceeded should the pressure switch fail Overload Protection This compressor is fitted with an overload protection device In the event that the motor becomes too hot a thermal protection device will cut the mains supply to the motor When the motor temperature returns to normal the mains supply will be restored automatically Preparing For Use Before connecting your compressor to the ma...

Страница 12: ...air receiver tank supply tube will become hot Connecting Hoses Accessories Warning Do not operate accessories at an air pressure greater than the maximum rated air pressure for the accessory Connect a hose to the compressor using the hose to compressor quick release connector Fig 11 When using the regulated air output first determine the working pressure of the accessory by referring to the access...

Страница 13: ... and stop when the ring is released If the valve does not operate as described or if the valve is stuck it must be replaced by qualified service personnel before using the compressor Warning Do not remove or attempt to adjust the safety valve Reset Button This compressor is equipped with a thermal overload device which operates as a safety device to protect the motor When the motor overheats for a...

Страница 14: ...the sight glass When re assembling Be sure the gasket is between the sight glass and the pump crankcase 8 Refill the compressor pump with an air compressor oil such as SAE 30 non detergent API CG CD Heavy Duty oil at slow intervals until the oil reaches the center of the red circle in the sight glass Use a SAE 10 during extreme winter conditions Maintenance Important Before carrying out any mainte...

Страница 15: ...dicates that used and end of life electrical and electronic equipment should not be disposed of in household waste For the proper disposal treatment recovery and recycling please take these products to designated collection points where they will be accepted on a free of charge basis Alternatively in some countries you may be able to return your products to your retailer upon the purchase of an eq...

Страница 16: ...requirements Waste electrical products should not be disposed of with household waste Please recycle where facilities exist Check with your Local Authority or retailer for recycling advice General warning Wear hearing protection Wear eye protection Wear respiratory protection CAUTION Hot surface Risk of electric shock The compressor must be disconnected from the mains supply before removing any co...

Отзывы: