General Information 

The 

BM350

 gas monitor offers a robust, easy to use, cost effective approach to providing a gas

monitoring system where safety matters. 

The 

monitor’s 

fibreglass

 housing is weather and corrosion resistant.  It is suitable for installation

where general equipment is in use. The housing door is hinged on the left side and is secured 

on the right with one latch. The display screen and status lights are visible through the 

transparent hinged cover. Optional mounting feet can be fixed to the back panel for vertical 

mounting. 

The alarm buzzer is located at the bottom of the unit and is on the left side of the power input. 

The gas sensor element is located on the bottom of the unit on the far left hand side. (or on a 

3M or 5M trailing cable) 

A large LCD display indicates vapour level. 

The concentration of Vapour 

is displayed in either parts per million (ppm) or milligram’s per 

cubic meter (mg/m

) depending on your specific requirements. 

The unit has an alarm, both audible and visual, and when a predetermined level of s is reached 

the alarm is activated, this alarm level is set at manufacture to customers requirements 

The monitor incorporates three fuses one domestic 3 amp plug head fuse, and one internal 

circuit board mounted 1A time delay fuse, and one 2A fuse to protect the alarm relay. 

If required an external alarm or device can be connected to the unit to provide other warnings of 

alarm level see installation instructions for more detail. 

The monitor is very easy to operate and requires no specialist knowledge or training. 

Automatic self-test 

The monitor incorporates a self testing feature, to quickly inform the user that monitoring is 

compromised, all foreseeable modes of failure have been taken in to account, in the unlikely 

event of a system failure the user will be alerted by the sensor malfunction light. 

Operating requirements 

The unit requires connection to a permanent electrical supply, see specification for your model 

on page. 

Consideration should be given to the power connection, if possible try not to use switched 

sockets or extension leads as these can easily be turned off leaving the monitor without power. 

The monitor is designed for 

indoor use only 

and should not be exposed to very high levels of 

condensing moisture. 

Technology 

The monitor uses the latest printed circuit technology, component parts have been

 selected to 

provide a high level of reliability combined with low drift over time. 

www.impact-test.co.uk  

  www.impact-test.com 

  www.impact-testsets.co.uk 

Содержание BM350

Страница 1: ...m User Guide User Guide www impact test com www impact test co uk www impact testsets co uk Methylene Chloride Monitor BM350 Impact Test Equipment Ltd www impact test co uk www impact test com www imp...

Страница 2: ...st Equipment Ltd Building 21 Stevenston Ind Est Stevenston Ayrshire KA20 3LR T 01294 602626 F 01294 461168 E sales impact test co uk Test Equipment www impact test co uk Test Sieves Accessories www im...

Страница 3: ...oduct description and safety features Installation instructions Power connection Relay connection and mounting location General information and operation Additional Information re sensor performance M...

Страница 4: ...requirements The monitor incorporates three fuses one domestic 3 amp plug head fuse and one internal circuit board mounted 1A time delay fuse and one 2A fuse to protect the alarm relay If required an...

Страница 5: ...use the monitor Although every effort is made to ensure accuracy this manual may contain technical unintentional technical inaccuracies On behalf of its clients Impact reserve the right to modify the...

Страница 6: ...sary where no socket outlet is present firstly ensure the mains lead is not connected isolate the plug so it cannot be connected accidentally loosen the two screws holding the lower cover in place rem...

Страница 7: ...he monitor alarm circuit is muted and the displayed reading is held low this is a normal and necessary part of installation after a short time the reading should settle down close to zero any reading...

Страница 8: ...evel has been reached Alarm sounder This activates when the alarm state is reached giving a high pitched continuous tone Sensor malfunction LED This alerts the user that a variation away from normal p...

Страница 9: ...f the sensor is exposed in extreme conditions such as very high humidity high temperatures or high contamination levels of organic vapours or other gases for a long period of time sensor performance m...

Страница 10: ...tests humidity temperature dust etc calibration should occur at least once a year The site manager is responsible for implementing the safety procedures on his site Impact is not responsible for impl...

Страница 11: ...e 0 199ppm 0 2000mg m 3 Dimensions 210 x 185 x 110 mm Accuracy 10 Cal level Visual alarm Red alarm led Weight 0 4kg Audio alarm Integrated sounder Response time 30 Seconds Typical 100 ppm Malfunction...

Отзывы: