MH630 240V / MH631 110V Vibrating Hammer
MH630
Bit angle
The bit can be secured at 12 different angles. To change the bit angle, slide the change ring forward, then
turn the change ring to change the bit angle. At the desired angle, slide the change ring back to the
original position. The bit will be secured in place.
1.
Change ring
NOTE:
•
The change ring cannot turn when the bit is not installed on the tool.
OPERATION
Chipping/Scaling/Demolition
Always use the side grip (auxiliary handle) and firmly hold the tool by both side
grip and switch handle during operations. Turn the tool on and apply slight
pressure on the tool so that the tool will not bounce around, uncontrolled.
Pressing very hard on the tool will not increase the efficiency.
MAINTENANCE
CAUTION:
•
Always be sure that the tool is switched off and unplugged before attempting to perform
inspection or maintenance.
•
Never use gasoline, benzine, thinner, alcohol or the like. Discoloration, deformation or cracks may
result.
Lubrication
CAUTION:
•
This servicing should be performed by Authorized Service Centers only.
This tool requires no hourly or daily lubrication because it has a grease-packed lubrication system. It
should be lubricated every time the carbon brushes are replaced. Send the complete tool to Authorized
Service Center for this lubrication service.