background image

 

iWaylink  Inc. 

 
 

208 

Enter                                                                                                              End 

*/$%ENTR*

 

 

*ZEND*

 

 

7-18-12 Insertion1Data 

To set up data1 to be inserted 

 

*L0S+*

 

Code39

 

*FSM+*

 

Code32 

 

 

Procedure: 

(A) Scan “Enter” ba

rcode 

(B) Scan “Insertion1Data” barcode

 

(C) Scan parameters from Hexadecimal / Decimal table 

(D) Scan “OK“ barcode

 

(E) Scan “End” barcode

 

 

 

Type 

Configuration Length 

Default Setting 

Code39 

NULL 

Code32 

NULL 

Содержание SW111

Страница 1: ...SW111 2D Bluetooth Barcode Scanner User s Manual Version 1 0 07 07 2020 ...

Страница 2: ...nfiguration by user manual 27 3 3 1 HID Mode Third party Bluetooth devices Mode selection code 1 27 3 3 2 BLE dongle MODE Mode selection code 4 28 3 4 BLE parameter configuration by user manual 29 3 4 1 BT Local Name 29 3 4 2 BLE Dongle Address 30 Chapter 4 BLE Connection Mode Instruction 31 4 1 How to into pairing mode 31 4 2 HID Mode Connection 32 4 3 BLE Dongle Mode Connection 35 4 3 1 HID mode...

Страница 3: ...e data 47 5 1 17 Tx Prefix 47 5 1 18 Prefix data 48 5 1 19 Tx Suffix 48 5 1 20 Suffix data 49 5 1 21 Tx CodeName 49 5 1 22 Tx CodeId 50 5 1 23 CodeId Position 50 5 1 24 Tx Code Length 50 5 1 25 ForceCase 51 5 1 26 Tx Delimiter 51 5 1 27 DelimiterChar 52 5 1 28 Tx Control Code 52 5 1 29 Date Time Transmission 53 5 1 30 Date Time Position 53 5 1 31 DateTimeSpareChar 54 5 1 32 BarUtf8Convert 54 5 2 G...

Страница 4: ... 2 20 CodeId Position 64 5 2 21 Tx Code Length 65 5 2 22 ForceCase 65 5 2 23 Tx Delimiter 66 5 2 24 DelimiterChar 66 5 2 25 Tx Control Code 67 5 2 26 Date Time Transmission 67 5 2 27 Date Time Position 68 5 2 28 DateTimeSpareChar 68 5 2 29 BarUtf8Convert 69 Chapter 6 General configuration setting 70 6 1 Host Interface 70 6 1 1 Version 70 6 1 2 Abort Setting 71 6 1 3 Enter ISP Mode 71 6 1 4 Barcode...

Страница 5: ...sion Timeout 83 6 3 7 Transmission Char Delay 84 6 3 8 Transmission Char Gap Time 84 6 3 9 Transmission Record Gap Time 85 6 4 Output Interface BLE HID Type 86 6 4 1 Caps Lock 86 6 4 2 Num Lock 87 6 4 3 Shift Release Caps Lock 87 6 4 4 Transmission Timeout 88 6 4 5 Transmission Char Delay 89 6 4 6 Transmission Char Gap Time 89 6 4 7 Transmission Record Gap Time 90 6 4 8 Output Language 90 6 4 9 BL...

Страница 6: ...02 7 2 9 Wait Add on Time 103 7 2 10 ConvertUpcaToEan13 103 7 2 11 Truncate Leading 104 7 2 12 Truncate Ending 104 7 2 13 Truncate Zero 105 7 2 14 Insertion1DataPosition 105 7 2 15 Insertion1Data 106 7 2 16 Insertion2DataPosition 106 7 2 17 Insertion2Data 107 7 3 UPC E 108 7 3 1 Read 108 7 3 2 Expansion 108 7 3 3 Check Digit 108 7 3 4 Addon2 109 7 3 5 Addon5 109 7 3 6 Wait Addon 109 7 3 7 Addon Se...

Страница 7: ...ding 118 7 4 11 Truncate Zero 119 7 4 12 Insertion1DataPosition 119 7 4 13 Insertion1Data 120 7 4 14 Insertion2DataPosition 120 7 4 15 Insert2Data 121 7 5 EAN 8 122 7 5 1 Read 122 7 5 2 Check Digit 122 7 5 3 Addon2 122 7 5 4 Addon5 123 7 5 5 Wait Addon 123 7 5 6 Addon Separator 123 7 5 7 Wait Addon Time 124 7 5 8 Truncate Leading 124 7 5 9 Truncate Ending 125 7 5 10 Truncate Zero 125 7 5 11 Insert...

Страница 8: ... 134 7 7 4 Expanded Min Code Length 135 7 7 5 Expanded Max Code Length 135 7 7 6 Truncate Leading 136 7 7 7 Truncate Ending 137 7 7 8 Truncate Zero 138 7 7 9 Insertion1DataPosition 139 7 7 10 Insertion1Data 140 7 7 11 Insertion2DataPosition 141 7 7 12 Insertion2Data 142 7 8 Gs1 Composite 143 7 8 1 Read 143 7 8 2 Upc Ean Version 143 7 8 3 Gs1Emulation 144 7 9 Codablock 145 7 9 1 CodablockARead 145 ...

Страница 9: ...on1DataPosition 160 7 10 11 Insertion1Data 161 7 10 12 Insertion2DataPosition 162 7 10 13 Insertion2Data 163 7 11 Tlc39 164 7 11 1 Read 164 7 11 2 Truncate Leading 164 7 11 3 Truncate Ending 165 7 11 4 Truncate Zero 165 7 11 5 Insertion1DataPosition 166 7 11 6 Insertion1Data 166 7 11 7 Insertion2DataPosition 167 7 11 8 Insertion2Data 167 7 12 QR Code 168 7 12 1 Read 168 7 12 2 Append 168 7 12 3 Mi...

Страница 10: ...de 179 7 14 1 Read 179 7 14 2 Min Code Length 179 7 14 3 Max Code Length 180 7 14 4 Truncate Leading 180 7 14 5 Truncate Ending 181 7 14 6 Truncate Zero 181 7 14 7 Insertion1DataPosition 182 7 14 8 Insertion1Data 182 7 14 9 Insertion2DataPosition 183 7 14 10 Insertion2Data 183 7 15 Aztec 184 7 15 1 Read 184 7 15 2 Append 184 7 15 3 Min Code Length 185 7 15 4 Max Code Length 185 7 15 5 Truncate Lea...

Страница 11: ... 195 7 17 3 Chksum Digit 195 7 17 4 Concatenation 196 7 17 5 Min Code Length 197 7 17 6 Max Code Length 197 7 17 7 Concatenation Time Out 198 7 17 8 Truncate Leading 198 7 17 9 Truncate Ending 199 7 17 10 Truncate Zero 199 7 17 11 Insertion 1Data Position 200 7 17 12 Insertion1Data 200 7 17 13 Insertion2DataPosition 201 7 17 14 Insertion2Data 201 7 18 Code39 202 7 18 1 Read 202 7 18 2 Chksum Verif...

Страница 12: ...ion1DataPosition 214 7 19 9 Insertion1Data 215 7 19 10 Insertion2DataPosition 215 7 19 11 Insertion2Data 216 7 20 Nec2of5 217 7 20 1 Read 217 7 20 2 Chksum Digit 217 7 20 3 Min Code Length 218 7 20 4 Max Code Length 218 7 20 5 Truncate Leading 219 7 20 6 Truncate Ending 219 7 20 7 Truncate Zero 220 7 20 8 Insertion1DataPosition 220 7 20 9 Insertion1Data 221 7 20 10 Insertion2DataPosition 221 7 20 ...

Страница 13: ...nsertion1Data 234 7 22 9 Insertion2DataPosition 234 7 22 10 Insertion2Data 235 7 23 Matrix2of5 236 7 23 1 Read 236 7 23 2 Min Code Length 236 7 23 3 Max Code Length 237 7 23 4 Truncate Leading 237 7 23 5 Truncate Ending 238 7 23 6 Truncate Zero 238 7 23 7 Insertion1DataPosition 239 7 23 8 Insertion1Data 239 7 23 9 Insertion2DataPosition 240 7 23 10 Insertion2Data 240 7 24 Code11 241 7 24 1 Read 24...

Страница 14: ...rtion2DataPosition 252 7 25 12 Insertion2Data 252 7 26 Gs1 128 253 7 26 1 Read 253 7 26 2 Min Code Length 253 7 26 3 Max Code Length 254 7 26 4 Truncate Leading 254 7 26 5 Truncate Ending 255 7 26 6 Truncate Zero 255 7 26 7 Insertion1DataPosition 256 7 26 8 Insertion1Data 256 7 26 9 Insertion2DataPosition 257 7 26 10 Insertion2Data 257 7 27 2D Postal 258 7 27 1 Read 258 7 27 2 Postnet Tx CheckDigi...

Страница 15: ...8 10 Insertion2Data 279 7 29 Korea Post 280 7 29 1 Read 280 7 29 2 Tx Checkdigit 280 7 29 3 Min Code Length 281 7 29 4 Max Code Length 281 7 29 5 Truncate Leading 282 7 29 6 Truncate Ending 282 7 29 7 Truncate Zero 283 7 29 8 Insertion1DataPosition 283 7 29 9 Insertion1Data 284 7 29 10 Insertion2DataPosition 284 7 29 11 Insertion2Data 285 7 30 Telepen 286 7 30 1 Read 286 7 30 2 Output 286 7 30 3 M...

Страница 16: ...e 300 Appendix C A 306 Dongle Setting 301 1 System 301 1 1 Version 301 2 HID mode 302 2 1 Caps Lock 302 2 2 Num Lock 302 2 3 Hid Keyboard Layout 303 2 4 Output language 304 2 5 Transmission Char Delay 304 2 6 Transmission Char Gap Time 305 2 7 Transmission Record Gap Time 306 3 USB COM mode 307 3 1 Transmission Char Delay 307 3 2 Transmission Char Gap Time 308 3 3 Transmission Record Gap Time 309 ...

Страница 17: ...idential installation This equipment generates uses and can radiated radio frequency energy and if not installed and used in accordance with the instructions may cause harmful interference to radio communications However there is no guarantee that interference will not occur in a particular installation If this equipment does cause harmful interference to radio or television reception which can be...

Страница 18: ...n this product The first initial charge will take up four hours to fully charge your battery Do not assemble disassemble the battery without technical support Do not use unspecified power adapter to charge the battery During the charging process if red color LED indicator keeps flashing rapidly terminate the charging and return the scanner to authorized dealers Once battery leakage or abnormal odo...

Страница 19: ...Code 93 93i Code 11 MSI Plessey Telepen Postal Codes 2D Codablock A Codablock F PDF417 MicroPDF417 Aztec Code Data Matrix MaxiCode QR Code Chinese Sensible Han Xin code Postal Codes Australian Post British Post Canadian Post China Post Japanese Post Korea Post Netherlands Post Planet Code Postnet Sensor 1280 x 800 pixels Global Shutter Pcs Up to 0 3 Scan Rate 60 frames per second Scan Angles Tilt ...

Страница 20: ...perature 40 70 C 40 to 158ºF Wireless Connection Bluetooth 5 0 IEEE 802 15 4 2 4 GHz Transceiver support HID profile and iOS Battery Li Ion Battery 3 6V 2040mAh and charge via USB port Voltage DC 5V 5 Ambient Light 0 to 100 000 lux Drop Durability 1 2m testing pending Safety Standard FCC CE VCCI certificate pending Power Consumption Under 300mA operation Under 100mA standby Calculated MTBF 375 000...

Страница 21: ... 4 4cm 1 73 57 3cm 22 5 Code 39 5 mil 7 0cm 2 76 30 1cm 11 85 Code 39 10mil 4 0cm 1 57 51 7cm 20 3 Code 39 20mil 4 4cm 1 73 80 0cm 31 5 Code 128 15mil 4 2cm 1 65 65 0cm 25 6 Data Matrix 10 mil 7 2cm 2 84 29 7cm 11 7 PDF417 6 7 mil 8 4cm 3 3 24 4cm 9 6 QR Code 15mil 3 9cm 1 54 41 4cm 16 3 ...

Страница 22: ...mary devices avail the users of their fundamental functionality some optional items are also available for your purchase to maximize efficiency of our product Inside the package contain the following items SW111 Wireless 2D Barcode Scanner Quick Start Guide Type C magnetic cable Stand Optional A 306 Dongle Optional ...

Страница 23: ...onal Enabled Limited Enabled Expanded Enabled Gs1 Composite Disabled Codablock CodablockA Disabled CodablockF Disabled PDF417 PDF417 Enabled MacroPdf417 Enabled MicroPdf417 Disabled Tlc39 Disabled QR Code Enabled DataMatrix Enabled MaxiCode Disabled Aztec Code Enabled ChineseSensible HanXinCode Disabled Codabar Nw7 Enabled Code39 Enabled Interleaved2of5 Enabled ...

Страница 24: ... Straight2of5 Industrial2of5 Straight2of5 Industrial2of5 Disabled Straight2of5IATA Disabled Matrix2of5 Disabled Code11 Disabled Code 128 Enabled Gs1 128 Disabled 2DPostal Disabled ChinaPost HongKong2of5 Disabled KoreaPost Disabled Telepen Disabled ...

Страница 25: ...mpt Blue Under BLE mode and BLE is not connected the blue LED indicator will be flash per 3 seconds When power on and BLE is connected the blue LED will be on Power indication Description White White LED shows the power status information 1 When connect cable for battery recharge the LED will change from off to on and then to off repeat the cycle until battery power is full then become constantly ...

Страница 26: ...n power off 3 2 BLE mode selection Code Table Bluetooth mode selection code Table Mode Description Mode selection Code HID Mode Third party Bluetooth dongle or build in Bluetooth device with USB HID mode 1 BLE Dongle Mode Applied to original factory dongle USB HID USB COM configurable 4 ...

Страница 27: ... devices Mode selection code 1 This mode is for user to configure with third party Bluetooth dongle or build in Bluetooth device with USB HID For HID mode Configuration please scan below barcodes step by step Procedure 1 Enter Enter setting ENTR 2 Mode selection Hid 5OZ1 3 End Exit setting ZEND ...

Страница 28: ... is for user to configure with purchased original factory dongle and it is USB HID USB COM configurable For BLE Dongle mode configuration please scan below barcodes step by step Procedure 1 Enter Enter setting ENTR 2 Mode selection BLE Dongle 5OZ4 3 End Exit setting ZEND ...

Страница 29: ... Configuration Max Configurable Length Default Setting Please refer to ASCII table 32 digits SmartBle Procedure 1 Enter Enter setting ENTR 2 BT Local Name AE4 3 Scan Hexadecimal Decimal Barcode table for input parameters 4 OK Selection confirmed OK 5 End Exit setting ZEND Example Set Local name as SmartBle A Scan Enter barcode B Scan BT Local Name barcode C Scan parameters from Hexadecimal Decimal...

Страница 30: ...FGY 3 Scan Hexadecimal Decimal Barcode table for input parameters 4 OK Selection confirmed OK 5 End Exit setting ZEND Example Set Remote Mac Address to 7F2D72DC5AE0 A Scan Enter barcode B Scan BLE Dongle Address barcode C Scan parameters from Hexadecimal decimal barcode table 7 F 2 D 7 2 D C 5 A E 0 OK Set BLE Dongle Address value to 7F2D72DC5AE0 D Scan End barcode Note If scanner connection mode ...

Страница 31: ...e 1 Scan following barcodes to get into pairing mode Enter ENTR Pairing Mode ZPAR 2 Take one paper clip to press on the reset hole from the bottom of scanner for 0 5 second as below picture Note Press the paper clip on the resent hole for around 0 5 second do not press it for long time to avoid entering into other operation mode ...

Страница 32: ... in system display Click right button of the mouse It will show screen below 2 Select Add a Device it starts to search nearby available Bluetooth device Make the scanner into pairing mode In the meantime if it can find available connecting Bluetooth device then it will show screen below From all the finding Bluetooth device search pairing device and click left button of the mouse ...

Страница 33: ...iWaylink Inc 33 It will start to connect Bluetooth connection then it will show screen below When it connects successfully it will show up the following screen ...

Страница 34: ...iWaylink Inc 34 3 In the meantime turn on the software to receive scanned result and scan barcode It will show screen below ...

Страница 35: ...ing scanner and BLE Dongle into pairing mode The scanner will establish the Bluetooth connection If connection successful the Blue LED indicator will be on If not please repeat the above mention action or check the Bluetooth parameters setting 3 When Bluetooth Connection established execute any word processing software for example Word notepad Excel and etc to receive to barcode data ...

Страница 36: ...nd BLE Dongle into pairing mode The scanner will establish the Bluetooth connection If connection successful the Blue LED indicator will be on If not please repeat the above mention action or check the Bluetooth parameters setting 3 When under USB COM mode please check device manager You will know which COM port is available then use Terminal program to receive scan data ...

Страница 37: ...h If the user wants to switch between HID USB COM mode please scan the following barcode Note Before scan the barcode make sure the scanner and the Bluetooth Dongle is Connected ENTER ENTR Enter configuration USB HID XKBD USB COM XCDC ...

Страница 38: ...off 2 Momentary When pressing Scan key turning on scanning light scanning barcode correctly or release Scan key the light will be turned off 3 Toggle Scan Toggle label if you intend to gain more flexibility in when to read a barcode A press on Scan Button will lead in switching on the light whereas either a successful decoding of a barcode or giving it Scan button press correspondingly switches of...

Страница 39: ...opriate barcode to specify the output interface 5OZ1 Hid 5OZ4 BLE Dongle 5 1 3 App Type Whether to enable special setting Normal Do not enable Mobile Phone When scanning the barcode on the phone to set up this function for better and accurate scanning 3OX0 Normal 3OX1 Mobile Phone ...

Страница 40: ...arcode is decoded successfully The higher level indicates the louder sound 1P30 Disable 1P31 Level1 1P32 Level2 1P33 Level3 1P34 Level4 5 1 5 Warning Beep Volume Scan the appropriate barcode to specify the volume of Warning Buzzer when an error occurs The higher level indicates the louder sound 5P71 Level1 5P72 Level2 5P73 Level3 5P74 Level4 ...

Страница 41: ... Pairing Barcode 5 1 7 Pairing Time When timeout period expires yet the BLE connection is not established the pairing process will terminate due to the failed attempt 1QK Configuration Range Unit Default Setting 1 255 Secs 1 Sec 90 Secs Procedure A Scan Enter barcode B Scan Pairing Time barcode C Scan parameters from Hexadecimal Decimal table D Scan OK barcode E Scan End barcode ...

Страница 42: ...to specify the buzzer frequency when a barcode is decoded successfully 8PS Configuration Range Unit Default Setting 100 5000 Hz 100Hz 2700 Hz Procedure A Scan Enter barcode B Scan Good Read Beep Freq barcode C Scan parameters from Hexadecimal Decimal table D Scan OK barcode E Scan End barcode ...

Страница 43: ...Time The time required to shut down scanning light when no barcode is scanned 2QL Configuration Range Unit Default Setting 1 30 Secs 1 Sec 10 Secs Procedure A Scan Enter barcode B Scan Good Read Beep Time barcode C Scan parameters from Hexadecimal Decimal table D Scan OK barcode E Scan End barcode Procedure A Scan Enter barcode B Scan Scan Time barcode C Scan parameters from Hexadecimal Decimal ta...

Страница 44: ...arameter is thus used to specify the length of time allocated for the scanner to elapse before power saving mode is initiated 3QM Configuration Range Unit Default Setting 1 255 Secs 1 Sec 15 Secs Procedure A Scan Enter barcode B Scan Scan Idle Time barcode C Scan parameters from Hexadecimal Decimal table D Scan OK barcode E Scan End barcode ...

Страница 45: ...ce to stay in standby before being totally shut down 4QN Configuration Range Unit Default Setting 30 2550 Secs 10 Sec 90 Secs 5 1 13 Tx Preamble Preamble Code refers to a sequence of characters which precedes both Prefix Code and barcode data during data transmission Scan the appropriate barcode to enable or disable Preamble Code 1ZK0 Disable 1ZK1 Enable Procedure A Scan Enter barcode B Scan Stand...

Страница 46: ...ers which appends to both barcode data and Suffix Code during data transmission Scan the appropriate barcode to enable or disable Postamble Code 2ZL0 Disable 2ZL1 Enable Configuration Length Default Setting 8 NULL Procedure A Scan Enter barcode B Scan Preamble data barcode C Scan parameters from Hexadecimal Decimal table D Scan OK barcode E Scan End barcode ...

Страница 47: ...posed between Preamble Code and barcode data during data transmission Scan the appropriate barcode to enable or disable Prefix Code 3ZM0 Disable 3ZM1 Enable Configuration Length Default Setting 8 CR LF 0x0D0x0A Procedure A Scan Enter barcode B Scan Postamble data barcode C Scan parameters from Hexadecimal Decimal table D Scan OK barcode E Scan End barcode ...

Страница 48: ...posed between barcode data and Postamble Code during data transmission Scan the appropriate barcode to enable or disable Suffix Code 4ZN0 Disable 4ZN1 Enable Configuration Length Default Setting 8 NULL Procedure A Scan Enter barcode B Scan Prefix data barcode C Scan parameters from Hexadecimal Decimal table D Scan OK barcode E Scan End barcode ...

Страница 49: ...tion enables to show the barcode symbology name Symbology name will be showing in front of barcode data 5ZO0 Disable 5ZO1 Enable Configuration Length Default Setting 8 NULL Procedure A Scan Enter barcode B Scan Suffix data barcode C Scan parameters from Hexadecimal Decimal table D Scan OK barcode E Scan End barcode ...

Страница 50: ...ay the Code ID 6ZP0 Disable 6ZP1 Enable 5 1 23 CodeId Position When Tx CodeId is Enable user can configure the output position of Code ID Before Barcode After Barcode 7ZQ0 Before 7ZQ1 After 5 1 24 Tx Code Length If user needs to know the length of the barcode data this configuration enables to indicate the barcode length in front of barcode data 0ZS0 Disable 0ZS1 Enable ...

Страница 51: ... digits to be same printing case even one barcode may have two kinds of case A000 None A001 Inverse A002 Lower A003 Upper 5 1 26 Tx Delimiter Scan the appropriate barcode to determine whether or not to interpose the delimiter parameter between the decoded message and timestamps 4ZW0 Disable 4ZW1 Enable ...

Страница 52: ...ine whether or not to transmit control code info along with the decoded message if the scanned barcode contains the special ASCII code 5ZX0 Disable 5ZX1 Enable Configuration Length Default Setting 1 NULL Procedure A Scan Enter barcode B Scan DelimiterChar barcode C Scan parameters from Hexadecimal Decimal table D Scan OK barcode E Scan End barcode ...

Страница 53: ...ransmission Whether or not to transmit Date or Time information Date Time 1ZT0 Disable 2ZU0 Disable 1ZT1 Enable 2ZU1 Enable 5 1 30 Date Time Position The parameter is to use for setting Date Time position before or after the barcode 3ZV0 Before 3ZV1 After ...

Страница 54: ... parameter has to be set as None 2 If the barcode is endoced in Utf8 then please set Big5 Gb2312 or Sjis according to the language of user s preference 6ZY0 None 6ZY2 Big5 6ZY3 SJis 6ZY4 Gb2312 Configuration Length Default Setting 1 NULL Procedure A Scan Enter barcode B Scan DateTimeSpareChar barcode C Scan parameters from Hexadecimal Decimal table D Scan OK barcode E Scan End barcode ...

Страница 55: ...ntend to gain more flexibility in when to read a barcode A press on Scan Button will lead in switching on the light whereas either a successful decoding of a barcode or giving it Scan button press correspondingly switches off the light 4 Present In this mode as long as any object is detected within scanning range the scanning light will be on automatically and the scanner can scan barcodes constan...

Страница 56: ...iate barcode to specify the output interface 3HV1 Usb Keyboard 3HV2 Usb Spp 5 2 3 App Type Whether to enable special setting Normal Do not enable Mobile Phone When scanning the barcode on the phone to set up this function for better and accurate scanning 1HT0 Normal 1HT1 Mobile Phone ...

Страница 57: ...barcode is decoded successfully The higher level indicates the louder sound 7HZ0 Disable 7HZ1 Level1 7HZ2 Level2 7HZ3 Level3 7HZ4 Level4 5 2 5 Warning Beep Volume Scan the appropriate barcode to specify the volume of Warning Buzzer when an error occurs The higher level indicates the louder sound 3I31 Level1 3I32 Level2 3I33 Level3 3I34 Level4 ...

Страница 58: ... 5I51 Enable 5 2 7 Good Read Beep Freq When decoding successfully it will make a sound and you can use this setting to set Beep Frequency 6IO Configuration Range Unit Default Setting 100 5000Hz 100Hz 2700 Hz Procedure A Scan Enter barcode B Scan Good Read Beep Freq barcode C Scan parameters from Hexadecimal Decimal table D Scan OK barcode E Scan End barcode ...

Страница 59: ...can Time The time required to shut down scanning light when no barcode is scanned 0JH Configuration Range Unit Default Setting 1 30 Secs 1 Sec 10 Secs Procedure A Scan Enter barcode B Scan Good Read Beep Time barcode C Scan parameters from Hexadecimal Decimal table D Scan OK barcode E Scan End barcode Procedure A Scan Enter barcode B Scan Scan Time barcode C Scan parameters from Hexadecimal Decima...

Страница 60: ...ring data transmission Scan the appropriate barcode to enable or disable Preamble Code 8SG0 Disable 8SG1 Enable 5 2 11 Preamble data Setting Preamble code content 5TC Configuration Length Default Setting 8 NULL Procedure A Scan Enter barcode B Scan Preamble data barcode C Scan parameters from Hexadecimal Decimal table D Scan OK barcode E Scan End barcode ...

Страница 61: ...data transmission Scan the appropriate barcode to enable or disable Postamble Code 0SH0 Disable 0SH1 Enable 5 2 13 Postamble data Setting Postamble code content 4TK Configuration Length Default Setting 8 CR LF 0x0D0x0A Procedure A Scan Enter barcode B Scan Postamble data barcode C Scan parameters from Hexadecimal Decimal table D Scan OK barcode E Scan End barcode ...

Страница 62: ...during data transmission Scan the appropriate barcode to enable or disable Prefix Code 1SI0 Disable 1SI1 Enable 5 2 15 Prefix data Setting Prefix content 3TS Configuration Length Default Setting 8 NULL Procedure A Scan Enter barcode B Scan Prefix data barcode C Scan parameters from Hexadecimal Decimal table D Scan OK barcode E Scan End barcode ...

Страница 63: ...during data transmission Scan the appropriate barcode to enable or disable Suffix Code 2SJ0 Disable 2SJ1 Enable 5 2 17 Suffix data Setting Suffix content 3U0 Configuration Length Default Setting 8 NULL Procedure A Scan Enter barcode B Scan Suffix data barcode C Scan parameters from Hexadecimal Decimal table D Scan OK barcode E Scan End barcode ...

Страница 64: ...barcode data 3SK0 Disable 3SK1 Enable 5 2 19 Tx CodeId When scanning the barcode User might want to know the symbology of the barcode ID This configuration enables to display the Code ID 4SL0 Disable 4SL1 Enable 5 2 20 CodeId Position When Tx CodeId is Enable user can configure the output position of Code ID Before Barcode After Barcode 5SM0 Before 5SM1 After ...

Страница 65: ...ode data this configuration enables to indicate the barcode length in front of barcode data 7SO0 Disable 7SO1 Enable 5 2 22 ForceCase This configuration enables to convert all output digits to be same printing case even one barcode may have two kinds of case 6SW0 None 6SW1 Inverse 6SW2 Lower 6SW3 Upper ...

Страница 66: ...e delimiter parameter between the decoded message and timestamps 2SS0 Disable 2SS1 Enable 5 2 24 DelimiterChar Setting Delimiter content 6T4 Configuration Length Default Setting 1 NULL Procedure A Scan Enter barcode B Scan DelimiterChar barcode C Scan parameters from Hexadecimal Decimal table D Scan OK barcode E Scan End barcode ...

Страница 67: ...ne whether or not to transmit control code info along with the decoded message if the scanned barcode contains the special ASCII code 3ST0 Disable 3ST1 Enable 5 2 26 Date Time Transmission Whether or not to transmit Date or Time information Date Time 8SP0 Disable 0SQ0 Disable 8SP1 Enable 0SQ1 Enable ...

Страница 68: ...fore or after the barcode 1SR0 Before 1SR1 After 5 2 28 DateTimeSpareChar Set separated symbol to distinguish date and time 7T5 Configuration Length Default Setting 1 NULL Procedure A Scan Enter barcode B Scan DateTimeSpareChar barcode C Scan parameters from Hexadecimal Decimal table D Scan OK barcode E Scan End barcode ...

Страница 69: ...8Convert 1 If the barcode is not encoded in Utf8 then the parameter has to be set as None 2 If the barcode is endoced in Utf8 then please set Big5 Gb2312 or Sjis according to the language of user s preference 4SU0 None 4SU2 Big5 4SU3 Sjis 4SU4 Gb2312 ...

Страница 70: ...mware version 2D Engine Version BLE firmware and module version BLE module Mac address if scanner Bluetooth function is available ZVER Procedure 1 Scan Enter Barcode 2 Scan Version barcode Note Firmware version listing as below Isp 0001 0001 ISP version Kernel 0001 0001 Firmware version 2D Eng DC000123BAA 2D Engine version BLE 0001 0001 00A9 BLE firmware and module version this is only available f...

Страница 71: ...1 Scan Enter Barcode 2 Scan Abort barcode Scan Abort Barcode to cancel the setting before you scan END barcode 6 1 3 Enter ISP Mode For software configuration User must connect the scanner with PC via USB cable and scan Enter ISP to enter the ISP mode PC might request for Driver installation please find the driver file C0801b inf in the CD ZISP Procedure 1 Scan Enter Barcode 2 Scan ISP barcode ...

Страница 72: ...low barcode to restore the symbologies to the default settings ZDEF Procedure 1 Scan Enter Barcode 2 Scan Barcode Default barcode 6 1 5 All Default Configuration setting to restored to factory default setting ZADE Procedure 1 Scan Enter Barcode 2 Scan All Default barcode ...

Страница 73: ...the scan result can be displayed normally ZLST Procedure 1 Scan Enter Barcode 2 Scan Parameter List barcode Example1 Perform the above and get the result as Language Setup Big 5 Output language is set Big 5 Not UTF 8 It means that only non UTF 8 code can be display in Chinese normally Example2 Perform the above and get result as Language Setup Big 5 Output language is set Big 5 UTF 8 Convert to Bi...

Страница 74: ...able it can be used as real time USB scanner There are two different output Interfaces USB HID Keyboard Type With USB HID type user can use Word Excel or any word processing software to receive barcode data USB SPP Virtual Com Type With USB COM type user need to use terminal software to receive the barcode data ...

Страница 75: ...xample Barcode data ABCdef Status Selection Caps Lock On Caps Lock Off UpperCase ABCdef abcDEF LowerCase abcDEF ABCdef Alt Keypad ABCdef ABCdef 6 2 2 Num Lock The settings of the numeric keypad the keypad must be selected if the application program only accepts numeric keypad The right hand side of the numeric keys on the keyboard and NumLock control key must be on 4760 AlphaPad 4761 NumPad ...

Страница 76: ... 4 Transmission Timeout After sending the information how long without a response will be timeout 27V Configuration Range Unit Default Setting 2 255 secs 1 sec 3 secs Procedure Example A Scan Enter barcode B Scan Transmission Timeout barcode C Scan parameters from Hexadecimal Decimal table D Scan OK barcode E Scan End barcode If configuration is 2 sec the parameter value is 2 sec 1 sec 2 ...

Страница 77: ... barcode B Scan Transmission Char Gap Time barcode C Scan parameters from Hexadecimal Decimal table D Scan OK barcode E Scan End barcode If configuration is 2 ms the parameter value is 2 ms 1 ms 2 Configuration Range Default Setting 0 255 0 Procedure A Scan Enter barcode B Scan Transmission Char Delay barcode C Scan parameters from Hexadecimal Decimal table D Scan OK barcode E Scan End barcode Con...

Страница 78: ...code B Scan Transmission Record Gap Time barcode C Scan parameters from Hexadecimal Decimal table D Scan OK barcode E Scan End barcode If configuration is 200 ms the parameter value is 200 ms 10 ms 20 6 2 8 Output Language To set up the target barcode encoding 7790 US 7791 Big5 7792 Gb2312 7793 Sjis Configuration Range Unit Default Setting 0 2550 ms 10 ms 0 ms ...

Страница 79: ... ENTR ZEND 6 2 9 USB HID Layout Setting The function enables the user to specify HID keyboard language HID Keyboard Layout setting 6780 EN 6786 SP 6781 UK 6787 PO 6782 JP 6788 SK 6783 FR 6789 KO 6784 GR 678A TR 6785 IT 678B SF ...

Страница 80: ...ck Nak response function 4850 None 4851 Ack Nak 6 3 2 STX ETX Characters Scan below barcodes to set if need to add STX data before the output barcode data ETX data after the output barcode data 5860 None 5861 STX ETX 6 3 3 Command Mode Scan the appropriate barcode to enable or disable Command mode for SPP 7880 Disable 7881 Enable ...

Страница 81: ...esent due to receive NAK signal When the amount of resending is out of range and STILL not yet received ACK which means Timeout 58O Procedure A Scan Enter barcode B Scan Retransmission Count barcode C Scan parameters from Hexadecimal Decimal table D Scan OK barcode E Scan End barcode Configuration Range Default Setting 0 255 2 ...

Страница 82: ...fter sending data 68P Procedure Example A Scan Enter barcode B Scan ACK Timeout barcode C Scan parameters from Hexadecimal Decimal table D Scan OK barcode E Scan End barcode If configuration is 2 sec the parameter value is 2 sec 1 sec 2 Configuration Range Unit Default Setting 2 255 secs 1 sec 3 secs ...

Страница 83: ...sponse will be timeout 88R Configuration Range Unit Default Setting 2 255 secs 1 sec 3 secs Procedure Example A Scan Enter barcode B Scan Transmission Timeout barcode C Scan parameters from Hexadecimal Decimal table D Scan OK barcode E Scan End barcode If configuration is 2 sec the parameter value is 2 sec 1 sec 2 ...

Страница 84: ... barcode B Scan Transmission Char Gap Time barcode C Scan parameters from Hexadecimal Decimal table D Scan OK barcode E Scan End barcode If configuration is 2 ms the parameter value is 2 ms 1 ms 2 Configuration Range Default Setting 0 255 0 Procedure A Scan Enter barcode B Scan Transmission Char Delay barcode C Scan parameters from Hexadecimal Decimal table D Scan OK barcode E Scan End barcode Con...

Страница 85: ...n 2 records 28U Procedure Example A Scan Enter barcode B Scan Transmission Record Gap Time barcode C Scan parameters from Hexadecimal Decimal table D Scan OK barcode E Scan End barcode If configuration is 200 ms the parameter value is 200 ms 10 ms 20 Configuration Range Unit Default Setting 0 2550 ms 10 ms 0 ms ...

Страница 86: ...ut Interface BLE HID Type 6 4 1 Caps Lock Caps lock setting for the barcode data display 5E91 LowerCase 5E93 Alt 5E92 UpperCase Example Barcode data ABCdef Status Selection Caps Lock On Caps Lock Off UpperCase ABCdef abcDEF LowerCase abcDEF ABCdef Alt Keypad ABCdef ABCdef ...

Страница 87: ...the application program only accepts numeric keypad The right hand side of the numeric keys on the keyboard and NumLock control key must be on 6EA0 Alpha Pad 6EA1 Num Pad 6 4 3 Shift Release Caps Lock Scan the following barcode can let the user to press Shift to release the status of Caps Lock 7EB0 Disable 7EB1 Enable ...

Страница 88: ...sponse will be timeout 4EZ Configuration Range Unit Default Setting 2 255 secs 1 sec 3 secs Procedure Example A Scan Enter barcode B Scan Transmission Timeout barcode C Scan parameters from Hexadecimal Decimal table D Scan OK barcode E Scan End barcode If configuration is 2 sec the parameter value is 2 sec 1 sec 2 ...

Страница 89: ...t Setting 0 255 0 Procedure A Scan Enter barcode B Scan Transmission Char Delay barcode C Scan parameters from Hexadecimal Decimal table D Scan OK barcode E Scan End barcode Configuration Range Unit Default Setting 0 255 ms 1ms 0 ms Procedure Example A Scan Enter barcode B Scan Transmission Char Gap Time barcode C Scan parameters from Hexadecimal Decimal table D Scan OK barcode E Scan End barcode ...

Страница 90: ...rcode B Scan Transmission Record Gap Time barcode C Scan parameters from Hexadecimal Decimal table D Scan OK barcode E Scan End barcode If configuration is 200 ms the parameter value is 200ms 10ms 20 6 4 8 Output Language To set up the target barcode encoding 0ED0 US 0ED1 Big5 0ED2 GB2312 0ED3 Sjis Configuration Range Unit Default Setting 0 2550 ms 10 ms 0 ms ...

Страница 91: ...c 91 Enter End ENTR ZEND 6 4 9 BLE HID Layout Setting The function enables the user to specify HID keyboard language 8EC0 EN 8EC6 SP 8EC1 UK 8EC7 PO 8EC2 JP 8EC8 SK 8EC3 FR 8EC9 KO 8EC4 GR 8ECA TR 8EC5 IT 8ECB SF ...

Страница 92: ...trol 6 5 1 OP Mode Set operating mode is Cable Mode or BLE Mode 53K0 Cable Mode 53K1 BLE Mode 6 5 2 System Beep Volume Whether it needs to activate Beep sound of system category ex power on music 13P0 Off 13P1 Level1 13P2 Level2 13P3 Level3 13P4 Level4 ...

Страница 93: ...End ENTR ZEND 6 5 3 Date format Setting the date display format 63U0 YYYYMMDD 63U3 YYMMDD 63U1 MMDDYYYY 63U4 MMDDYY 63U2 DDMMYYYY 63U5 DDMMYY 6 5 4 Time format Setting the Time display format 73V0 HHMMSS 73V1 HHMM 73V2 MMSS ...

Страница 94: ...aration sign of Time 34H Configuration Length Default Setting 1 Procedure A Scan Enter barcode B Scan Date Separator barcode C Scan parameters from Hexadecimal Decimal table D Scan OK barcode E Scan End barcode Procedure A Scan Enter barcode B Scan Time Separator barcode C Scan parameters from Hexadecimal Decimal table D Scan OK barcode E Scan End barcode ...

Страница 95: ... digits 84M Configuration Length Default Setting 1 0x03 Procedure A Scan Enter barcode B Scan STX Escape Character barcode C Scan parameters from Hexadecimal Decimal table D Scan OK barcode E Scan End barcode Procedure A Scan Enter barcode B Scan ETX Escape Character barcode C Scan parameters from Hexadecimal Decimal table D Scan OK barcode E Scan End barcode ...

Страница 96: ...within a period of time 75B Procedure Example A Scan Enter barcode B Scan Setup Timeout Time barcode C Scan parameters from Hexadecimal Decimal table D Scan OK barcode E Scan End barcode If configuration is 2 minutes the parameter value is 2 minutes 10 sec 12 Configuration Range Unit Default Setting 10 2550 Secs 10 Sec 60 Secs ...

Страница 97: ...te Time It is able to read below barcodes to set the Date Time YYMMDDhhmmss ZCLK Configuration Length 12 Procedure A Scan Enter Barcode B Scan Set Date Time Barcode C Scan parameters from Hexadecimal Decimal table D Scan OK barcode E Scan End Barcode ...

Страница 98: ...blockA Disable 1 600 0 0 CodablockF Disable 1 2048 0 0 PDF417 Enable 1 2750 0 0 MicroPdf417 Disable 1 366 0 0 Tlc39 Disable 0 0 QR Code Enable 1 7089 0 0 DataMatrix Enable 1 3116 0 0 MaxiCode Disable 1 150 0 0 Aztec Enable 1 3832 0 0 ChineseSensible HanXinCo de Disable 1 7833 0 0 Codabar Nw7 Enable 4 60 0 0 Code39 Enable 0 48 0 0 Interleaved2of5 Enable 4 80 0 0 Nec2of5 Enable 4 80 0 0 Code93 Enabl...

Страница 99: ...iWaylink Inc 99 Enter End ENTR ZEND Code 128 Enable 0 80 0 0 Gs1 128 Disable 0 80 0 0 2DPostal Disable 0 0 ChinaPost HongKong2of5 Disable 4 80 0 0 KoreaPost Disable 4 48 0 0 Telepen Disable 1 60 0 0 ...

Страница 100: ...D 7 2 UPC A 7 2 1 Read Whether the barcode can be scanned QVB0 Disable QVB1 Enable 7 2 2 Check Digit Whether to send Check Digit KV50 Disable KV51 Enable 7 2 3 Addon2 Whether able to read 2 digit additional code MV70 Disable MV71 Enable ...

Страница 101: ...le to read 5 digit additional code NV80 Disable NV81 Enable 7 2 5 Wait Add On Whether only to read barcode with additional code OV90 Disable OV91 Enable 7 2 6 Add on Separator Whether use space to distinguish barcode and additional code PVA0 Disable PVA1 Enable ...

Страница 102: ...efault setting Off the scanner treats Coupon codes and Extended Coupon Codes as single bar codes 2 Allow If you scan the Allow Connection code when the scanner sees the coupon code and the extended coupon code in a single scan it transmits both as one symbology Otherwise it transmits the first coupon code it reads 3 Require If you scan the Require Concatenation code the scanner must see and read t...

Страница 103: ... A Scan Enter barcode B Scan Wait Addon Time barcode C Scan parameters from Hexadecimal Decimal table D Scan OK barcode E Scan End barcode If configuration is 20 ms the parameter value is 20 ms 1 ms 20 7 2 10 ConvertUpcaToEan13 When UPC A Converted to EAN 13 is selected UPC A bar codes are converted to 13 digit EAN 13 codes by adding a zero to the front JV40 Convert JV41 Off Configuration Range Un...

Страница 104: ...n parameters from Hexadecimal Decimal table D Scan OK barcode E Scan End barcode 7 2 12 Truncate Ending To set up the number of digits to be omitted from the end of the barcode L10 Procedure A Scan Enter barcode B Scan Truncate Ending barcode C Scan parameters from Hexadecimal Decimal table D Scan OK barcode E Scan End barcode Configuration Range Default Setting 0 12 0 Configuration Range Default ...

Страница 105: ...barcode N120 Disable N121 Enable 7 2 14 Insertion1DataPosition To set up the position to insert data1 P14 Procedure A Scan Enter barcode B Scan Insertion1DataPosition barcode C Scan parameters from Hexadecimal Decimal table D Scan OK barcode E Scan End barcode Configuration Range Default Setting 0 12 0 ...

Страница 106: ... Hexadecimal Decimal table D Scan OK barcode E Scan End barcode 7 2 16 Insertion2DataPosition To set up the position to insert data2 K18 Procedure A Scan Enter barcode B Scan Insertion2DataPosition barcode C Scan parameters from Hexadecimal Decimal table D Scan OK barcode E Scan End barcode Configuration Length Default Setting 2 NULL Configuration Range Default Setting 0 12 0 ...

Страница 107: ...17 Insertion2Data To set up data2 to be inserted M1A Procedure A Scan Enter barcode B Scan Insertion2Data barcode C Scan parameters from Hexadecimal Decimal table D Scan OK barcode E Scan End barcode Configuration Length Default Setting 2 NULL ...

Страница 108: ...hether the barcode can be scanned MVG0 Disable MVG1 Enable 7 3 2 Expansion This expansion function is for UPC E only It will extend the barcode to be 12 digits by 0 OVI0 Disable OVI1 Enable 7 3 3 Check Digit Whether to send Check Digit PVJ0 Disable PVJ1 Enable ...

Страница 109: ...on2 Whether able to read 2 digit additional code IVL0 Disable IVL1 Enable 7 3 5 Addon5 Whether able to read 5 digit additional code JVM0 Disable JVM1 Enable 7 3 6 Wait Addon Whether only to read barcode with additional code KVN0 Disable KVN1 Enable ...

Страница 110: ...ed to use Wait Add on If to get the additional code in a specified decoding time then indicate otherwise do not indicate KVE Procedure Example A Scan Enter barcode B Scan Wait Addon Time barcode C Scan parameters from Hexadecimal Decimal table D Scan OK barcode E Scan End barcode If configuration is 20 ms the parameter value is 20 ms 1 ms 20 Configuration Range Unit Default Setting 0 500 ms 1 ms 1...

Страница 111: ...n parameters from Hexadecimal Decimal table D Scan OK barcode E Scan End barcode 7 3 10 TruncateEnding To set up the number of digits to be omitted from the end of the barcode EUS Procedure A Scan Enter barcode B Scan TruncateEnding barcode C Scan parameters from Hexadecimal Decimal table D Scan OK barcode E Scan End barcode Configuration Range Default Setting 0 8 0 Configuration Range Default Set...

Страница 112: ...barcode GUU0 Disable GUU1 Enable 7 3 12 Insertion1DataPosition To set up the position to insert data1 9UW Procedure A Scan Enter barcode B Scan Insertion1DataPosition barcode C Scan parameters from Hexadecimal Decimal table D Scan OK barcode E Scan End barcode Configuration Range Default Setting 0 8 0 ...

Страница 113: ...m Hexadecimal Decimal table D Scan OK barcode E Scan End barcode 7 3 14 Insertion2DataPosition To set up the position to insert data2 EV0 Procedure A Scan Enter barcode B Scan Insertion2DataPosition barcode C Scan parameters from Hexadecimal Decimal table D Scan OK barcode E Scan End barcode Configuration Length Default Setting 2 NULL Configuration Range Default Setting 0 8 0 ...

Страница 114: ...15 Insertion2Data To set up data2 to be inserted GV2 Procedure A Scan Enter barcode B Scan Insertion2Data barcode C Scan parameters from Hexadecimal Decimal table D Scan OK barcode E Scan End barcode Configuration Length Default Setting 2 NULL ...

Страница 115: ...D 7 4 EAN 13 7 4 1 Read Whether the barcode can be scanned MVP0 Disable MVP1 Enable 7 4 2 Check Digit Whether to send Check Digit NVQ0 Disable NVQ1 Enable 7 4 3 Addon2 Whether able to read 2 digit additional code OVR0 Disable OVR1 Enable ...

Страница 116: ...ble to read 5 digit additional code PVS0 Disable PVS1 Enable 7 4 5 Wait Addon Whether only to read barcode with additional code QVT0 Disable QVT1 Enable 7 4 6 Addon Separator Whether use space to distinguish barcode and additional code IVU0 Disable IVU1 Enable ...

Страница 117: ...ditional code need to use Wait Add on If to get the additional code in a specified decoding time then indicate otherwise do not indicate KVE Procedure Example A Scan Enter barcode B Scan Wait Addon Time barcode C Scan parameters from Hexadecimal Decimal table D Scan OK barcode E Scan End barcode If configuration is 20 ms the parameter value is 20 ms 1 ms 20 Configuration Range Unit Default Setting...

Страница 118: ... parameters from Hexadecimal Decimal table D Scan OK barcode E Scan End barcode 7 4 10 Truncate Ending To set up the number of digits to be omitted from the end of the barcode Q1E Procedure A Scan Enter barcode B Scan Truncate Ending barcode C Scan parameters from Hexadecimal Decimal table D Scan OK barcode E Scan End barcode Configuration Range Default Setting 0 13 0 Configuration Range Default S...

Страница 119: ...barcode J1G0 Disable J1G1 Enable 7 4 12 Insertion1DataPosition To set up the position to insert data1 L1I Procedure A Scan Enter barcode B Scan Insertion1DataPosition barcode C Scan parameters from Hexadecimal Decimal table D Scan OK barcode E Scan End barcode Configuration Range Default Setting 0 13 0 ...

Страница 120: ... Hexadecimal Decimal table D Scan OK barcode E Scan End barcode 7 4 14 Insertion2DataPosition To set up the position to insert data2 P1M Procedure A Scan Enter barcode B Scan Insertion2DataPosition barcode C Scan parameters from Hexadecimal Decimal table D Scan OK barcode E Scan End barcode Configuration Length Default Setting 2 NULL Configuration Range Default Setting 0 13 0 ...

Страница 121: ... 15 Insert2Data To set up data2 to be inserted I1O Procedure A Scan Enter barcode B Scan Insertion2Data barcode C Scan parameters from Hexadecimal Decimal table D Scan OK barcode E Scan End barcode Configuration Length Default Setting 2 NULL ...

Страница 122: ...D 7 5 EAN 8 7 5 1 Read Whether the barcode can be scanned KVW0 Disable KVW1 Enable 7 5 2 Check Digit Whether to send Check Digit LVX0 Disable LVX1 Enable 7 5 3 Addon2 Whether able to read 2 digit additional code MVY0 Disable MVY1 Enable ...

Страница 123: ...ble to read 5 digit additional code NVZ0 Disable NVZ1 Enable 7 5 5 Wait Addon Whether only to read barcode with additional code PW00 Disable PW01 Enable 7 5 6 Addon Separator Whether use space to distinguish barcode and additional code QW10 Disable QW11 Enable ...

Страница 124: ...arameters from Hexadecimal Decimal table D Scan OK barcode E Scan End barcode If configuration is 20 ms the parameter value is 20 ms 1 ms 20 7 5 8 Truncate Leading To set up the number of digits to be omitted from the beginning of the barcode GUC Procedure A Scan Enter barcode B Scan Truncate Leading barcode C Scan parameters from Hexadecimal Decimal table D Scan OK barcode E Scan End barcode Conf...

Страница 125: ...e end of the barcode 9UE Procedure A Scan Enter barcode B Scan Truncate Ending barcode C Scan parameters from Hexadecimal Decimal table D Scan OK barcode E Scan End barcode 7 5 10 Truncate Zero Whether to omit 0 from the beginning of the barcode BUG0 Disable BUG1 Enable Configuration Range Default Setting 0 8 0 ...

Страница 126: ...de C Scan parameters from Hexadecimal Decimal table D Scan OK barcode E Scan End barcode 7 5 12 Insertion1Data To set up data1 to be inserted FUK Configuration Range Default Setting 0 8 0 Configuration Length Default Setting 2 NULL Procedure A Scan Enter barcode B Scan Insertion1Data barcode C Scan parameters from Hexadecimal Decimal table D Scan OK barcode E Scan End barcode ...

Страница 127: ...de C Scan parameters from Hexadecimal Decimal table D Scan OK barcode E Scan End barcode 7 5 14 Insertion2Data To set up data2 to be inserted AUO Procedure A Scan Enter barcode B Scan Insertion2Data barcode C Scan parameters from Hexadecimal Decimal table D Scan OK barcode E Scan End barcode Configuration Range Default Setting 0 8 0 Configuration Length Default Setting 2 NULL ...

Страница 128: ...code can be scanned IW20 Disable IW21 Enable 7 6 2 Chksum Verification To set up the regulation of check digit only barcode meet the regulation can be scanned JW30 Type10 JW31 Type10 Transmit JW32 2Type10 JW33 2Type10 Transmit JW34 Type11 JW35 Type11 Transmit JW36 Disable ...

Страница 129: ...meters from Hexadecimal Decimal table D Scan OK barcode E Scan End barcode 7 6 4 Max Code Length To set up the maximum length of the barcode longer than this length barcode cannot be scanned LW5 Procedure A Scan Enter barcode B Scan Max Code Length barcode C Scan parameters from Hexadecimal Decimal table D Scan OK barcode E Scan End barcode Configuration Range Default Setting 4 48 4 Configuration ...

Страница 130: ...n parameters from Hexadecimal Decimal table D Scan OK barcode E Scan End barcode 7 6 6 Truncate Ending To set up the number of digits to be omitted from the end of the barcode O2K Procedure A Scan Enter barcode B Scan Truncate Ending barcode C Scan parameters from Hexadecimal Decimal table D Scan OK barcode E Scan End barcode Configuration Range Default Setting 0 48 0 Configuration Range Default S...

Страница 131: ...barcode Q2M0 Disable Q2M1 Enable 7 6 8 Insertion1DataPosition To set up the position to insert data1 J2O Procedure A Scan Enter barcode B Scan Insertion1DataPosition barcode C Scan parameters from Hexadecimal Decimal table D Scan OK barcode E Scan End barcode Configuration Range Default Setting 0 48 0 ...

Страница 132: ...A Scan Enter barcode B Scan Insertion2DataPosition barcode C Scan parameters from Hexadecimal Decimal table D Scan OK barcode E Scan End barcode Configuration Length Default Setting 2 NULL Procedure A Scan Enter barcode B Scan Insertion1Data barcode C Scan parameters from Hexadecimal Decimal table D Scan OK barcode E Scan End barcode Configuration Range Default Setting 0 48 0 ...

Страница 133: ...11 Insertion2Data To set up data2 to be inserted P2U Procedure A Scan Enter barcode B Scan Insertion2Data barcode C Scan parameters from Hexadecimal Decimal table D Scan OK barcode E Scan End barcode Configuration Length Default Setting 2 NULL ...

Страница 134: ...bar 7 7 1 Omnidirectional Read Whether the barcode can be scanned MW60 Disable MW61 Enable 7 7 2 Limited Read Whether the barcode can be scanned NW70 Disable NW71 Enable 7 7 3 Expanded Read Whether the barcode can be scanned OW80 Disable OW81 Enable ...

Страница 135: ...meters from Hexadecimal Decimal table D Scan OK barcode E Scan End barcode 7 7 5 Expanded Max Code Length To set up the maximum length of the barcode longer than this length barcode cannot be scanned QWA Procedure A Scan Enter barcode B Scan Expanded Max Code Length barcode C Scan parameters from Hexadecimal Decimal table D Scan OK barcode E Scan End barcode Configuration Range Default Setting 4 7...

Страница 136: ... barcode O76 Gs1DataBar P7Y Gs1DataBar Limited M8C Gs1DataBar Expanded Procedure A Scan Enter barcode B Scan Truncate Leading barcode C Scan parameters from Hexadecimal Decimal table D Scan OK barcode E Scan End barcode Type Configuration Range Default Setting Gs1DataBar 0 74 0 Gs1DataBar Limited 0 74 0 Gs1DataBar Expanded 0 74 0 ...

Страница 137: ...rcode Q78 Gs1DataBar J80 Gs1DataBar Limited O8E Gs1DataBar Expanded Procedure A Scan Enter barcode B Scan Truncate Ending barcode C Scan parameters from Hexadecimal Decimal table D Scan OK barcode E Scan End barcode Type Configuration Range Default Setting Gs1DataBar 0 74 0 Gs1DataBar Limited 0 74 0 Gs1DataBar Expanded 0 74 0 ...

Страница 138: ... Enter End ENTR ZEND 7 7 8 Truncate Zero Whether to omit 0 from the beginning of the barcode Gs1DataBar J7A0 Disable J7A1 Enable Gs1DataBar Limited L820 Disable L821 Enable Gs1DataBar Expanded Q8G0 Disable Q8G1 Enable ...

Страница 139: ...Bar N84 Gs1DataBar Limited J8I Gs1DataBar Expanded Procedure A Scan Enter barcode B Scan Insertion1DataPosition barcode C Scan parameters from Hexadecimal Decimal table D Scan OK barcode E Scan End barcode Type Configuration Range Default Setting Gs1DataBar 0 74 0 Gs1DataBar Limited 0 74 0 Gs1DataBar Expanded 0 74 0 ...

Страница 140: ...P86 Gs1DataBar Limited L8K Gs1DataBar Expanded Procedure A Scan Enter barcode B Scan Insertion1Data barcode C Scan parameters from Hexadecimal Decimal table D Scan OK barcode E Scan End barcode Type Configuration Length Default Setting Gs1DataBar 2 NULL Gs1DataBar Limited 2 NULL Gs1DataBar Expanded 2 NULL ...

Страница 141: ...aBar I88 Gs1DataBar Limited N8M Gs1DataBar Expanded Procedure A Scan Enter barcode B Scan Insertion2DataPosition barcode C Scan parameters from Hexadecimal Decimal table D Scan OK barcode E Scan End barcode Type Configuration Range Default Setting Gs1DataBar 0 74 0 Gs1DataBar Limited 0 74 0 Gs1DataBar Expanded 0 74 0 ...

Страница 142: ...K8A Gs1DataBar Limited P8O Gs1DataBar Expanded Procedure A Scan Enter barcode B Scan Insertion2Data barcode C Scan parameters from Hexadecimal Decimal table D Scan OK barcode E Scan End barcode Type Configuration Length Default Setting Gs1DataBar 2 NULL Gs1DataBar Limited 2 NULL Gs1DataBar Expanded 2 NULL ...

Страница 143: ...de can be scanned IX10 Disable IX11 Enable 7 8 2 Upc Ean Version Scan the UPC EAN Version on bar code to decode GS1 Composite symbols that have a U P C or an EAN linear component This does not affect GS1 Composite symbols with a GS1 128 or GS1 linear component JX20 Disable JX21 Enable ...

Страница 144: ...are expanded out to 16 digits Gs1DataBar If GS1 databar Emulation is scanned all retail codes U P C UPC E EAN8 EAN13 are expanded out to 16 digits Code Expansion Off If GS1 Code Expansion Off is scanned retail code expansion id disable and UPC E expansion is controlled bt the UPC E0 Expanded setting EAN8 to EAN13 If EAN8 to EAN13 Conversion is scanned all EAN8 bar codes are converted to EAN13 form...

Страница 145: ...ink Inc 145 Enter End ENTR ZEND 7 9 Codablock 7 9 1 CodablockARead Whether the barcode can be scanned IWB0 Disable IWB1 Enable 7 9 2 CodablockFRead Whether the barcode can be scanned NWG0 Disable NWG1 Enable ...

Страница 146: ...e less than this length barcode cannot be scanned JWC CodablocA OWH CodablocF Procedure A Scan Enter barcode B Scan Min Code Length barcode C Scan parameters from Hexadecimal Decimal table D Scan OK barcode E Scan End barcode Type Configuration Range Default Setting CodablocA 1 600 1 CodablocF 1 2048 1 ...

Страница 147: ...nger than this length barcode cannot be scanned LWE CodablocA QWJ CodablocF Procedure A Scan Enter barcode B Scan Max Code Length barcode C Scan parameters from Hexadecimal Decimal table D Scan OK barcode E Scan End barcode Type Configuration Range Default Setting CodablocA 1 600 600 CodablocF 1 2048 2048 ...

Страница 148: ...be omitted from the beginning the barcode EZE CodablocA I4U CodablocF Procedure A Scan Enter barcode B Scan Truncate Leading barcode C Scan parameters from Hexadecimal Decimal table D Scan OK barcode E Scan End barcode Type Configuration Range Default Setting CodablocA 0 600 0 CodablocF 0 2048 0 ...

Страница 149: ... be omitted from the end of the barcode GZG CodablocA K4W CodablocF Procedure A Scan Enter barcode B Scan Truncate Ending barcode C Scan parameters from Hexadecimal Decimal table D Scan OK barcode E Scan End barcode Type Configuration Range Default Setting CodablocA 0 600 0 CodablocF 0 2048 0 ...

Страница 150: ...e 9ZI1 Enable M4Y1 Enable 7 9 8 Insertion1DataPosition To set up the position to insert data1 BZK CodablocA P50 CodablocF Procedure A Scan Enter barcode B Scan Insertion1DataPosition barcode C Scan parameters from Hexadecimal Decimal table D Scan OK barcode E Scan End barcode Type Configuration Range Default Setting CodablocA 0 600 0 CodablocF 0 2048 0 ...

Страница 151: ...ata1 to be inserted DZM CodablocA I52 CodablocF Type Configuration Length Default Setting CodablocA 2 NULL CodablocF 2 NULL Procedure A Scan Enter barcode B Scan Insertion1Data barcode C Scan parameters from Hexadecimal Decimal table D Scan OK barcode E Scan End barcode ...

Страница 152: ...osition to insert data2 FZO CodablocA K54 CodablocF Procedure A Scan Enter barcode B Scan Insertion2DataPosition barcode C Scan parameters from Hexadecimal Decimal table D Scan OK barcode E Scan End barcode Type Configuration Range Default Setting CodablocA 0 600 0 CodablocF 0 2048 0 ...

Страница 153: ...data2 to be inserted HZQ CodablocA M56 CodablocF Type Configuration Length Default Setting CodablocA 2 NULL CodablocF 2 NULL Procedure A Scan Enter barcode B Scan Insertion2Data barcode C Scan parameters from Hexadecimal Decimal table D Scan OK barcode E Scan End barcode ...

Страница 154: ...canned JWL0 Disable JWL1 Enable 7 10 2 MacroPdf417 Read MacroPDF417 is an implementation of PDF417 capable of encoding very large amounts of data into multiple PDF417 bar codes When this selection is enabled these multiple bar codes are assembled into a single data string KWM0 Disable KWM1 Enable ...

Страница 155: ... information from multiple images When Poor Quality PDF On is scanned poor quality PDF code reading is improved but the scanner s snappiness is decreased making it less aggressive when reading good quality bar codes This Setting does not affect 1D bar code reading QWS0 Disable QWS1 Enable 7 10 4 MicroPdf417 Read Whether the barcode can be scanned JWU0 Disable JWU1 Enable ...

Страница 156: ...de less than this length barcode cannot be scanned LWN Pdf417 KWV MicroPdf417 Procedure A Scan Enter barcode B Scan Min Code Length barcode C Scan parameters from Hexadecimal Decimal table D Scan OK barcode E Scan End barcode Type Configuration Range Default Setting Pdf417 1 2750 1 MicroPdf417 1 366 1 ...

Страница 157: ...longer than this length barcode cannot be scanned NWP Pdf417 MWX MicroPdf417 Procedure A Scan Enter barcode B Scan Max Code Length barcode C Scan parameters from Hexadecimal Decimal table D Scan OK barcode E Scan End barcode Type Configuration Range Default Setting Pdf417 1 2750 2750 MicroPdf417 1 366 366 ...

Страница 158: ...be omitted from the beginning of the barcode O58 Pdf417 CYM MicroPdf417 Procedure A Scan Enter barcode B Scan Truncate Leading barcode C Scan parameters from Hexadecimal Decimal table D Scan OK barcode E Scan End barcode Type Configuration Range Default Setting Pdf417 0 2750 0 MicroPdf417 0 366 0 ...

Страница 159: ...ocedure A Scan Enter barcode B Scan Truncate Ending barcode C Scan parameters from Hexadecimal Decimal table D Scan OK barcode E Scan End barcode 7 10 9 Truncate Zero Whether to omit 0 from the beginning of the barcode Pdf417 MicroPdf417 J5C0 Disable GYQ0 Disable J5C1 Enable GYQ1 Enable Type Configuration Range Default Setting Pdf417 0 2750 0 MicroPdf417 0 366 0 ...

Страница 160: ...position to insert data1 L5E Pdf417 9YS MicroPdf417 Procedure A Scan Enter barcode B Scan Insertion1DataPosition barcode C Scan parameters from Hexadecimal Decimal table D Scan OK barcode E Scan End barcode Type Configuration Range Default Setting Pdf417 0 2750 0 MicroPdf417 0 366 0 ...

Страница 161: ... data1 to be inserted N5G Pdf417 BYU MicroPdf417 Procedure A Scan Enter barcode B Scan Insertion1Data barcode C Scan parameters from Hexadecimal Decimal table D Scan OK barcode E Scan End barcode Type Configuration Length Default Setting Pdf417 2 NULL MicroPdf417 2 NULL ...

Страница 162: ...position to insert data2 P5I Pdf417 DYW MicroPdf417 Procedure A Scan Enter barcode B Scan Insertion2DataPosition barcode C Scan parameters from Hexadecimal Decimal table D Scan OK barcode E Scan End barcode Type Configuration Range Default Setting Pdf417 0 2750 0 MicroPdf417 0 366 0 ...

Страница 163: ... data2 to be inserted I5K Pdf417 FYY MicroPdf417 Procedure A Scan Enter barcode B Scan Insertion2Data barcode C Scan parameters from Hexadecimal Decimal table D Scan OK barcode E Scan End barcode Type Configuration Length Default Setting Pdf417 2 NULL MicroPdf417 2 NULL ...

Страница 164: ...PX81 Enable 7 11 2 Truncate Leading To set up the number of digits to be omitted from the beginning of the barcode 9Z0 Procedure A Scan Enter barcode B Scan Truncate Leading barcode C Scan parameters from Hexadecimal Decimal table D Scan OK barcode E Scan End barcode Configuration Range Default Setting 0 48 0 ...

Страница 165: ...e end of the barcode BZ2 Procedure A Scan Enter barcode B Scan Truncate Ending barcode C Scan parameters from Hexadecimal Decimal table D Scan OK barcode E Scan End barcode 7 11 4 Truncate Zero Whether to omit 0 from the beginning of the barcode DZ40 Disable DZ41 Enable Configuration Range Default Setting 0 48 0 ...

Страница 166: ...e C Scan parameters from Hexadecimal Decimal table D Scan OK barcode E Scan End barcode 7 11 6 Insertion1Data To set up data1 to be inserted HZ8 Configuration Range Default Setting 0 48 0 Configuration Length Default Setting 2 NULL Procedure A Scan Enter barcode B Scan Insertion1Data barcode C Scan parameters from Hexadecimal Decimal table D Scan OK barcode E Scan End barcode ...

Страница 167: ...e C Scan parameters from Hexadecimal Decimal table D Scan OK barcode E Scan End barcode 7 11 8 Insertion2Data To set up data2 to be inserted CZC Procedure A Scan Enter barcode B Scan Insertion2Data barcode C Scan parameters from Hexadecimal Decimal table D Scan OK barcode E Scan End barcode Configuration Range Default Setting 0 48 0 Configuration Length Default Setting 2 NULL ...

Страница 168: ...ppend To set up whether able to scan multiple related barcodes and decode them into a complete QR Code barcode Off Disable this function On Enable this function the scanning light will not be off when you are scanning related barcodes a beep sound will be occurred when the related barcodes are successfully decoded NXF0 Off NXF2 On ...

Страница 169: ...ers from Hexadecimal Decimal table D Scan OK barcode E Scan End barcode 7 12 4 Max Code Length To set up the maximum length of the barcode longer than this length barcode cannot be scanned KXC Procedure A Scan Enter barcode B Scan Max Code Length barcode C Scan parameters from Hexadecimal Decimal table D Scan OK barcode E Scan End barcode Configuration Range Default Setting 1 7089 1 Configuration ...

Страница 170: ...parameters from Hexadecimal Decimal table D Scan OK barcode E Scan End barcode 7 12 6 Truncate Ending To set up the number of digits to be omitted from the end of the barcode M5O Procedure A Scan Enter barcode B Scan Truncate Ending barcode C Scan parameters from Hexadecimal Decimal table D Scan OK barcode E Scan End barcode Configuration Range Default Setting 0 7089 0 Configuration Range Default ...

Страница 171: ...arcode O5Q0 Disable O5Q1 Enable 7 12 8 Insertion1DataPosition To set up the position to insert data1 Q5S Procedure A Scan Enter barcode B Scan Insertion1DataPosition barcode C Scan parameters from Hexadecimal Decimal table D Scan OK barcode E Scan End barcode Configuration Range Default Setting 0 7089 0 ...

Страница 172: ...A Scan Enter barcode B Scan Insertion2DataPosition barcode C Scan parameters from Hexadecimal Decimal table D Scan OK barcode E Scan End barcode Configuration Length Default Setting 2 NULL Procedure A Scan Enter barcode B Scan Insertion1Data barcode C Scan parameters from Hexadecimal Decimal table D Scan OK barcode E Scan End barcode Configuration Range Default Setting 0 7089 0 ...

Страница 173: ...11 Insertion2Data To set up data2 to be inserted N5Y Procedure A Scan Enter barcode B Scan Insertion2Data barcode C Scan parameters from Hexadecimal Decimal table D Scan OK barcode E Scan End barcode Configuration Length Default Setting 2 NULL ...

Страница 174: ... Enable 7 13 2 Min Code Length To set up the minimum length of the barcode less than this length barcode cannot be scanned PXH Procedure A Scan Enter barcode B Scan Min Code Length barcode C Scan parameters from Hexadecimal Decimal table D Scan OK barcode E Scan End barcode Configuration Range Default Setting 1 3116 1 ...

Страница 175: ... parameters from Hexadecimal Decimal table D Scan OK barcode E Scan End barcode 7 13 4 Truncate Leading To set up the number of digits to be omitted from the beginning of the barcode M6E Procedure A Scan Enter barcode B Scan Truncate Leading barcode C Scan parameters from Hexadecimal Decimal table D Scan OK barcode E Scan End barcode Configuration Range Default Setting 1 3116 3116 Configuration Ra...

Страница 176: ... end of the barcode O6G Procedure A Scan Enter barcode B Scan Truncate Ending barcode C Scan parameters from Hexadecimal Decimal table D Scan OK barcode E Scan End barcode 7 13 6 Truncate Zero Whether to omit 0 from the beginning of the barcode Q6I0 Disable Q6I1 Enable Configuration Range Default Setting 0 3116 0 ...

Страница 177: ... C Scan parameters from Hexadecimal Decimal table D Scan OK barcode E Scan End barcode 7 13 8 Insertion1Data To set up data1 to be inserted L6M Configuration Range Default Setting 0 3116 0 Configuration Length Default Setting 2 NULL Procedure A Scan Enter barcode B Scan Insertion1Data barcode C Scan parameters from Hexadecimal Decimal table D Scan OK barcode E Scan End barcode ...

Страница 178: ... C Scan parameters from Hexadecimal Decimal table D Scan OK barcode E Scan End barcode 7 13 10 Insertion2Data To set up data2 to be inserted P6Q Procedure A Scan Enter barcode B Scan Insertion2Data barcode C Scan parameters from Hexadecimal Decimal table D Scan OK barcode E Scan End barcode Configuration Range Default Setting 0 3116 0 Configuration Length Default Setting 2 NULL ...

Страница 179: ...Enable 7 14 2 Min Code Length To set up the minimum length of the barcode less than this length barcode cannot be scanned MXN Procedure A Scan Enter barcode B Scan Min Code Length barcode C Scan parameters from Hexadecimal Decimal table D Scan OK barcode E Scan End barcode Configuration Range Default Setting 1 150 1 ...

Страница 180: ...n parameters from Hexadecimal Decimal table D Scan OK barcode E Scan End barcode 7 14 4 Truncate Leading To set up the number of digits to be omitted from the beginning of the barcode I6S Procedure A Scan Enter barcode B Scan Truncate Leading barcode C Scan parameters from Hexadecimal Decimal table D Scan OK barcode E Scan End barcode Configuration Range Default Setting 1 150 150 Configuration Ran...

Страница 181: ...e end of the barcode K6U Procedure A Scan Enter barcode B Scan Truncate Ending barcode C Scan parameters from Hexadecimal Decimal table D Scan OK barcode E Scan End barcode 7 14 6 Truncate Zero Whether to omit 0 from the beginning of the barcode M6W0 Disable M6W1 Enable Configuration Range Default Setting 0 150 0 ...

Страница 182: ...e C Scan parameters from Hexadecimal Decimal table D Scan OK barcode E Scan End barcode 7 14 8 Insertion1Data To set up data1 to be inserted I70 Configuration Range Default Setting 0 150 0 Configuration Length Default Setting 2 NULL Procedure A Scan Enter barcode B Scan Insertion1Data barcode C Scan parameters from Hexadecimal Decimal table D Scan OK barcode E Scan End barcode ...

Страница 183: ... C Scan parameters from Hexadecimal Decimal table D Scan OK barcode E Scan End barcode 7 14 10 Insertion2Data To set up data2 to be inserted M74 Procedure A Scan Enter barcode B Scan Insertion2Data barcode C Scan parameters from Hexadecimal Decimal table D Scan OK barcode E Scan End barcode Configuration Range Default Setting 0 150 0 Configuration Length Default Setting 2 NULL ...

Страница 184: ...ppend To set up whether able to scan multiple related barcodes and decode them into a complete Aztec barcode Off Disable this function On Enable this function the scanning light will not be off when you are scanning related barcodes a beep sound will be occurred when the related barcodes are successfully decoded LXV0 Off LXV2 On ...

Страница 185: ...ers from Hexadecimal Decimal table D Scan OK barcode E Scan End barcode 7 15 4 Max Code Length To set up the maximum length of the barcode longer than this length barcode cannot be scanned IXS Procedure A Scan Enter barcode B Scan Max Code Length barcode C Scan parameters from Hexadecimal Decimal table D Scan OK barcode E Scan End barcode Configuration Range Default Setting 1 3832 1 Configuration ...

Страница 186: ...parameters from Hexadecimal Decimal table D Scan OK barcode E Scan End barcode 7 15 6 Truncate Ending To set up the number of digits to be omitted from the end of the barcode M7M Procedure A Scan Enter barcode B Scan Truncate Ending barcode C Scan parameters from Hexadecimal Decimal table D Scan OK barcode E Scan End barcode Configuration Range Default Setting 0 3832 0 Configuration Range Default ...

Страница 187: ...arcode O7O0 Disable O7O1 Enable 7 15 8 Insertion1DataPosition To set up the position to insert data1 Q7Q Procedure A Scan Enter barcode B Scan Insertion1DataPosition barcode C Scan parameters from Hexadecimal Decimal table D Scan OK barcode E Scan End barcode Configuration Range Default Setting 0 3832 0 ...

Страница 188: ...A Scan Enter barcode B Scan Insertion2DataPosition barcode C Scan parameters from Hexadecimal Decimal table D Scan OK barcode E Scan End barcode Configuration Length Default Setting 2 NULL Procedure A Scan Enter barcode B Scan Insertion1Data barcode C Scan parameters from Hexadecimal Decimal table D Scan OK barcode E Scan End barcode Configuration Range Default Setting 0 3832 0 ...

Страница 189: ...11 Insertion2Data To set up data2 to be inserted N7W Configuration Length Default Setting 2 NULL Procedure A Scan Enter barcode B Scan Insertion2Data barcode C Scan parameters from Hexadecimal Decimal table D Scan OK barcode E Scan End barcode ...

Страница 190: ...ble NXX1 Enable 7 16 2 Min Code Length To set up the minimum length of the barcode less than this length barcode cannot be scanned OXY Procedure A Scan Enter barcode B Scan Min Code Length barcode C Scan parameters from Hexadecimal Decimal table D Scan OK barcode E Scan End barcode Configuration Range Default Setting 1 7833 1 ...

Страница 191: ... parameters from Hexadecimal Decimal table D Scan OK barcode E Scan End barcode 7 16 4 Truncate Leading To set up the number of digits to be omitted from the beginning of the barcode 9V4 Procedure A Scan Enter barcode B Scan Truncate Leading barcode C Scan parameters from Hexadecimal Decimal table D Scan OK barcode E Scan End barcode Configuration Range Default Setting 1 7833 7833 Configuration Ra...

Страница 192: ... end of the barcode BV6 Procedure A Scan Enter barcode B Scan Truncate Ending barcode C Scan parameters from Hexadecimal Decimal table D Scan OK barcode E Scan End barcode 7 16 6 Truncate Zero Whether to omit 0 from the beginning of the barcode DV80 Disable DV81 Enable Configuration Range Default Setting 0 7833 0 ...

Страница 193: ... C Scan parameters from Hexadecimal Decimal table D Scan OK barcode E Scan End barcode 7 16 8 Insertion1Data To set up data1 to be inserted HVC Configuration Range Default Setting 0 7833 0 Configuration Length Default Setting 2 NULL Procedure A Scan Enter barcode B Scan Insertion1Data barcode C Scan parameters from Hexadecimal Decimal table D Scan OK barcode E Scan End barcode ...

Страница 194: ... C Scan parameters from Hexadecimal Decimal table D Scan OK barcode E Scan End barcode 7 16 10 Insertion2Data To set up data2 to be inserted CVG Procedure A Scan Enter barcode B Scan Insertion2Data barcode C Scan parameters from Hexadecimal Decimal table D Scan OK barcode E Scan End barcode Configuration Range Default Setting 0 7833 0 Configuration Length Default Setting 2 NULL ...

Страница 195: ...scanned KY20 Disable KY21 Enable 7 17 2 Start End Transmission Whether to send the start code and end code of the barcode LY30 Disable LY31 Enable 7 17 3 Chksum Digit To set up the regulation of check digit and whether to send the check digit MY40 Disable MY41 Modulo 16 MY42 Modulo 16 Transmit ...

Страница 196: ...aving a D start character adjacent to a symbol having a D stop character In this case the two messages are concatenated into one with the D characters omitted Select Require to prevent the scanner from decoding a single D Codabar symbol without its companion This selection has no effect on Codabar symbols without Stop Start D characters NY50 Off NY51 On NY52 Require ...

Страница 197: ...meters from Hexadecimal Decimal table D Scan OK barcode E Scan End barcode 7 17 6 Max Code Length To set up the maximum length of the barcode longer than this length barcode cannot be scanned PY7 Procedure A Scan Enter barcode B Scan Max Code Length barcode C Scan parameters from Hexadecimal Decimal table D Scan OK barcode E Scan End barcode Configuration Range Default Setting 2 60 4 Configuration...

Страница 198: ...ode B Scan Concatenation Time Out barcode C Scan parameters from Hexadecimal Decimal table D Scan OK barcode E Scan End barcode 7 17 8 Truncate Leading To set up the number of digits to be omitted from the beginning of the barcode Q06 Procedure A Scan Enter barcode B Scan Truncate Leading barcode C Scan parameters from Hexadecimal Decimal table D Scan OK barcode E Scan End barcode Configuration Ra...

Страница 199: ...e end of the barcode J08 Procedure A Scan Enter barcode B Scan Truncate Ending barcode C Scan parameters from Hexadecimal Decimal table D Scan OK barcode E Scan End barcode 7 17 10 Truncate Zero Whether to omit 0 from the beginning of the barcode L0A0 Disable L0A1 Enable Configuration Range Default Setting 0 60 0 ...

Страница 200: ...e C Scan parameters from Hexadecimal Decimal table D Scan OK barcode E Scan End barcode 7 17 12 Insertion1Data To set up the data1 to be inserted P0E Configuration Range Default Setting 0 60 0 Configuration Length Default Setting 2 NULL Procedure A Scan Enter barcode B Scan Insertion1Data barcode C Scan parameters from Hexadecimal Decimal table D Scan OK barcode E Scan End barcode ...

Страница 201: ...C Scan parameters from Hexadecimal Decimal table D Scan OK barcode E Scan End barcode 7 17 14 Insertion2Data To set up the data2 to be inserted K0I Procedure A Scan Enter barcode B Scan Insertion2Data barcode C Scan parameters from Hexadecimal Decimal table D Scan OK barcode E Scan End barcode Configuration Range Default Setting 0 60 0 Configuration Length Default Setting 2 NULL ...

Страница 202: ... 7 18 Code39 7 18 1 Read Whether the barcode can be scanned DC00 Disable DC01 Enable 7 18 2 Chksum Verification To set up the regulation of check digit and whether to send the check digit FC20 Disable FC21 Validate FC22 Validate Transmit ...

Страница 203: ...End Transmission Whether to indicate in the beginning and the end of the barcode EC10 Disable EC11 Enable 7 18 4 Type To set up whether able to decode the Code39 of Full ASCII to indicate lowercase and special symbologies GC30 Standard GC31 Full ASCII ...

Страница 204: ...meters from Hexadecimal Decimal table D Scan OK barcode E Scan End barcode 7 18 6 Max Code Length To set up the maximum length of the barcode longer than this length barcode cannot be scanned 9C5 Procedure A Scan Enter barcode B Scan Max Code Length barcode C Scan parameters from Hexadecimal Decimal table D Scan OK barcode E Scan End barcode Configuration Range Default Setting 0 48 0 Configuration...

Страница 205: ... 18 8 Truncate Leading To set up the number of digits to be omitted from the beginning of the barcode M0K Code39 GSE Code32 Procedure A Scan Enter barcode B Scan Truncate Leading barcode C Scan parameters from Hexadecimal Decimal table D Scan OK barcode E Scan End barcode Type Configuration Range Default Setting Code39 0 48 0 Code32 0 48 0 ...

Страница 206: ... Procedure A Scan Enter barcode B Scan Truncate Ending barcode C Scan parameters from Hexadecimal Decimal table D Scan OK barcode E Scan End barcode 7 18 10 Truncate Zero Whether to omit 0 from the beginning of the barcode Code39 Code32 Q0O0 Disable BSI0 Disable Q0O1 Enable BSI1 Enable Type Configuration Range Default Setting Code39 0 48 0 Code32 0 48 0 ...

Страница 207: ...up the position to insert data1 J0Q Code39 DSK Code32 Procedure A Scan Enter barcode B Scan Insertion1DataPosition barcode C Scan parameters from Hexadecimal Decimal table D Scan OK barcode E Scan End barcode Type Configuration Range Default Setting Code39 0 48 0 Code32 0 48 0 ...

Страница 208: ...et up data1 to be inserted L0S Code39 FSM Code32 Procedure A Scan Enter barcode B Scan Insertion1Data barcode C Scan parameters from Hexadecimal Decimal table D Scan OK barcode E Scan End barcode Type Configuration Length Default Setting Code39 2 NULL Code32 2 NULL ...

Страница 209: ...up the position to insert data2 N0U Code39 HSO Code32 Procedure A Scan Enter barcode B Scan Insertion2DataPosition barcode C Scan parameters from Hexadecimal Decimal table D Scan OK barcode E Scan End barcode Type Configuration Range Default Setting Code39 0 48 0 Code32 0 48 0 ...

Страница 210: ...et up data2 to be inserted P0W Code39 ASQ Code32 Procedure A Scan Enter barcode B Scan Insertion2Data barcode C Scan parameters from Hexadecimal Decimal table D Scan OK barcode E Scan End barcode Type Configuration Length Default Setting Code39 2 NULL Code32 2 NULL ...

Страница 211: ...7 19 Interleaved2of5 7 19 1 Read Whether the barcode can be scanned OYO0 Disable OYO1 Enable 7 19 2 Chksum Digit To set up the regulation of check digit and whether to send the check digit PYP0 Disable PYP1 Validate PYP2 Validate Transmit ...

Страница 212: ...meters from Hexadecimal Decimal table D Scan OK barcode E Scan End barcode 7 19 4 Max Code Length To set up the maximum length of the barcode longer than this length barcode cannot be scanned IYR Procedure A Scan Enter barcode B Scan Max Code Length barcode C Scan parameters from Hexadecimal Decimal table D Scan OK barcode E Scan End barcode Configuration Range Default Setting 2 80 4 Configuration...

Страница 213: ...n parameters from Hexadecimal Decimal table D Scan OK barcode E Scan End barcode 7 19 6 Truncate Ending To set up the number of digits to be omitted from the end of the barcode M1S Procedure A Scan Enter barcode B Scan Truncate Ending barcode C Scan parameters from Hexadecimal Decimal table D Scan OK barcode E Scan End barcode Configuration Range Default Setting 0 80 0 Configuration Range Default ...

Страница 214: ...barcode O1U0 Disable O1U1 Enable 7 19 8 Insertion1DataPosition To set up the position to insert data1 Q1W Procedure A Scan Enter barcode B Scan Insertion1DataPosition barcode C Scan parameters from Hexadecimal Decimal table D Scan OK barcode E Scan End barcode Configuration Range Default Setting 0 80 0 ...

Страница 215: ... A Scan Enter barcode B Scan Insertion2DataPosition barcode C Scan parameters from Hexadecimal Decimal table D Scan OK barcode E Scan End barcode Configuration Length Default Setting 2 NULL Procedure A Scan Enter barcode B Scan Insertion1Data barcode C Scan parameters from Hexadecimal Decimal table D Scan OK barcode E Scan End barcode Configuration Range Default Setting 0 80 0 ...

Страница 216: ... Insertion2Data To set up the data2 to be inserted O22 Configuration Length Default Setting 2 NULL Procedure A Scan Enter barcode B Scan Insertion2Data barcode C Scan parameters from Hexadecimal Decimal table D Scan OK barcode E Scan End barcode ...

Страница 217: ...END 7 20 Nec2of5 7 20 1 Read Whether the barcode can be scanned KYT0 Disable KYT1 Enable 7 20 2 Chksum Digit To set up the regulation of check digit and whether to send the check digit LYU0 Disable LYU1 Validate LYU2 Validate Transmit ...

Страница 218: ...rameters from Hexadecimal Decimal table D Scan OK barcode E Scan End barcode 7 20 4 Max Code Length To set up maximum length of the barcode longer than this length barcode cannot be scanned NYW Procedure A Scan Enter barcode B Scan Max Code Length barcode C Scan parameters from Hexadecimal Decimal table D Scan OK barcode E Scan End barcode Configuration Range Default Setting 2 80 4 Configuration R...

Страница 219: ...n parameters from Hexadecimal Decimal table D Scan OK barcode E Scan End barcode 7 20 6 Truncate Ending To set up the number of digits to be omitted from the end of the barcode CZU Procedure A Scan Enter barcode B Scan Truncate Ending barcode C Scan parameters from Hexadecimal Decimal table D Scan OK barcode E Scan End barcode Configuration Range Default Setting 0 80 0 Configuration Range Default ...

Страница 220: ...barcode EZW0 Disable EZW1 Enable 7 20 8 Insertion1DataPosition To set up the position to insert data1 GZY Procedure A Scan Enter barcode B Scan Insertion1DataPosition barcode C Scan parameters from Hexadecimal Decimal table D Scan OK barcode E Scan End barcode Configuration Range Default Setting 0 80 0 ...

Страница 221: ... A Scan Enter barcode B Scan Insertion2DataPosition barcode C Scan parameters from Hexadecimal Decimal table D Scan OK barcode E Scan End barcode Configuration Length Default Setting 2 NULL Procedure A Scan Enter barcode B Scan Insertion1Data barcode C Scan parameters from Hexadecimal Decimal table D Scan OK barcode E Scan End barcode Configuration Range Default Setting 0 80 0 ...

Страница 222: ...11 Insertion2Data To set up data2 to be inserted O04 Configuration Length Default Setting 2 NULL Procedure A Scan Enter barcode B Scan Insertion2Data barcode C Scan parameters from Hexadecimal Decimal table D Scan OK barcode E Scan End barcode ...

Страница 223: ... ZEND 7 21 Code93 7 21 1 Read Whether the barcode can be scanned OYX0 Disable OYX1 Enable 7 21 2 Append To set up whether able to scan multiple related barcodes and decode them in to a complete Code93 barcode KZ10 Disable KZ11 Enable ...

Страница 224: ...meters from Hexadecimal Decimal table D Scan OK barcode E Scan End barcode 7 21 4 Max Code Length To set up the maximum length of the barcode longer than this length barcode cannot be scanned QYZ Procedure A Scan Enter barcode B Scan Max Code Length barcode C Scan parameters from Hexadecimal Decimal table D Scan OK barcode E Scan End barcode Configuration Range Default Setting 0 80 0 Configuration...

Страница 225: ...parameters from Hexadecimal Decimal table D Scan OK barcode E Scan End barcode 7 21 6 Truncate Ending To set up the number of digits to be omitted from the end of the barcode Q3C Procedure A Scan Enter barcode B Scan Truncate Ending barcode C Scan parameters from Hexadecimal Decimal table D Scan OK barcode E Scan End barcode Configuration Range Default Setting 0 80 0 Configuration Range Default Se...

Страница 226: ...barcode J3E0 Disable J3E1 Enable 7 21 8 Insertion1DataPosition To set up the position to insert data1 L3G Procedure A Scan Enter barcode B Scan Insertion1DataPosition barcode C Scan parameters from Hexadecimal Decimal table D Scan OK barcode E Scan End barcode Configuration Range Default Setting 0 80 0 ...

Страница 227: ...A Scan Enter barcode B Scan Insertion2DataPosition barcode C Scan parameters from Hexadecimal Decimal table D Scan OK barcode E Scan End barcode Configuration Length Default Setting 2 NULL Procedure A Scan Enter barcode B Scan Insertion1Data barcode C Scan parameters from Hexadecimal Decimal table D Scan OK barcode E Scan End barcode Configuration Range Default Setting 0 80 0 ...

Страница 228: ...11 Insertion2Data To set up data2 to be inserted I3M Configuration Length Default Setting 2 NULL Procedure A Scan Enter barcode B Scan Insertion2Data barcode C Scan parameters from Hexadecimal Decimal table D Scan OK barcode E Scan End barcode ...

Страница 229: ...iWaylink Inc 229 Enter End ENTR ZEND 7 22 Straight2of5 Industrial2of5 7 22 1 Read Whether the barcode can be scanned Straight2of5 Straight2of5IATA LZ20 Disable OZ50 Disable LZ21 Enable OZ51 Enable ...

Страница 230: ...han this length barcode cannot be scanned MZ3 Straight2of5 PZ6 Straight2of5IATA Procedure A Scan Enter barcode B Scan Min Code Length barcode C Scan parameters from Hexadecimal Decimal table D Scan OK barcode E Scan End barcode Type Configuration Range Default Setting Straight2of5 1 48 4 Straight2of5IATA 1 48 4 ...

Страница 231: ...han this length barcode cannot be scanned NZ4 Straight2of5 QZ7 Straight2of5IATA Procedure A Scan Enter barcode B Scan Max Code Length barcode C Scan parameters from Hexadecimal Decimal table D Scan OK barcode E Scan End barcode Type Configuration Range Default Setting Straight2of5 1 48 48 Straight2of5IATA 1 48 48 ...

Страница 232: ...n parameters from Hexadecimal Decimal table D Scan OK barcode E Scan End barcode 7 22 5 Truncate Ending To set up the number of digits to be omitted from the end of the barcode J26 Procedure A Scan Enter barcode B Scan Truncate Ending barcode C Scan parameters from Hexadecimal Decimal table D Scan OK barcode E Scan End barcode Configuration Range Default Setting 0 48 0 Configuration Range Default ...

Страница 233: ...barcode L280 Disable L281 Enable 7 22 7 Insertion1DataPosition To set up the position to insert data1 N2A Procedure A Scan Enter barcode B Scan Insertion1DataPosition barcode C Scan parameters from Hexadecimal Decimal table D Scan OK barcode E Scan End barcode Configuration Range Default Setting 0 48 0 ...

Страница 234: ...A Scan Enter barcode B Scan Insertion2DataPosition barcode C Scan parameters from Hexadecimal Decimal table D Scan OK barcode E Scan End barcode Configuration Length Default Setting 2 NULL Procedure A Scan Enter barcode B Scan Insertion1Data barcode C Scan parameters from Hexadecimal Decimal table D Scan OK barcode E Scan End barcode Configuration Range Default Setting 0 48 0 ...

Страница 235: ...10 Insertion2Data To set up data2 to be inserted K2G Procedure A Scan Enter barcode B Scan Insertion2Data barcode C Scan parameters from Hexadecimal Decimal table D Scan OK barcode E Scan End barcode Configuration Length Default Setting 2 NULL ...

Страница 236: ...1 Enable 7 23 2 Min Code Length To set up the minimum length of the barcode less than this length barcode cannot be scanned KZA Procedure A Scan Enter barcode B Scan Min Code Length barcode C Scan parameters from Hexadecimal Decimal table D Scan OK barcode E Scan End barcode Configuration Range Default Setting 1 80 4 ...

Страница 237: ...can parameters from Hexadecimal Decimal table D Scan OK barcode E Scan End barcode 7 23 4 Truncate Leading To set up the number of digits to be omitted from the beginning of the barcode M4G Procedure A Scan Enter barcode B Scan Truncate Leading barcode C Scan parameters from Hexadecimal Decimal table D Scan OK barcode E Scan End barcode Configuration Range Default Setting 1 80 80 Configuration Ran...

Страница 238: ...e end of the barcode O4I Procedure A Scan Enter barcode B Scan Truncate Ending barcode C Scan parameters from Hexadecimal Decimal table D Scan OK barcode E Scan End barcode 7 23 6 Truncate Zero Whether to omit 0 from the beginning of the barcode Q4K0 Disable Q4K1 Enable Configuration Range Default Setting 0 80 0 ...

Страница 239: ...e C Scan parameters from Hexadecimal Decimal table D Scan OK barcode E Scan End barcode 7 23 8 Insertion1Data To set up data1 to be inserted L4O Configuration Range Default Setting 0 80 0 Configuration Length Default Setting 2 NULL Procedure A Scan Enter barcode B Scan Insertion1Data barcode C Scan parameters from Hexadecimal Decimal table D Scan OK barcode E Scan End barcode ...

Страница 240: ...e C Scan parameters from Hexadecimal Decimal table D Scan OK barcode E Scan End barcode 7 23 10 Insertion2Data To set up data2 to be inserted P4S Procedure A Scan Enter barcode B Scan Insertion2Data barcode C Scan parameters from Hexadecimal Decimal table D Scan OK barcode E Scan End barcode Configuration Range Default Setting 0 80 0 Configuration Length Default Setting 2 NULL ...

Страница 241: ...241 Enter End ENTR ZEND 7 24 Code11 7 24 1 Read Whether the barcode can be scanned MZC0 Disable MZC1 Enable 7 24 2 Chksum Digit To choose how many digits to use for the check digit PZF0 1Checkdigit PZF1 2Checkdigit ...

Страница 242: ...meters from Hexadecimal Decimal table D Scan OK barcode E Scan End barcode 7 24 4 Max Code Length To set up the maximum length of the barcode longer than this length barcode cannot be scanned OZE Procedure A Scan Enter barcode B Scan Max Code Length barcode C Scan parameters from Hexadecimal Decimal table D Scan OK barcode E Scan End barcode Configuration Range Default Setting 1 80 4 Configuration...

Страница 243: ...n parameters from Hexadecimal Decimal table D Scan OK barcode E Scan End barcode 7 24 6 Truncate Ending To set up the number of digits to be omitted from the end of the barcode K2Y Procedure A Scan Enter barcode B Scan Truncate Ending barcode C Scan parameters from Hexadecimal Decimal table D Scan OK barcode E Scan End barcode Configuration Range Default Setting 0 80 0 Configuration Range Default ...

Страница 244: ...barcode N300 Disable N301 Enable 7 24 8 Insertion1DataPosition To set up the position to insert data1 P32 Procedure A Scan Enter barcode B Scan Insertion1DataPosition barcode C Scan parameters from Hexadecimal Decimal table D Scan OK barcode E Scan End barcode Configuration Range Default Setting 0 80 0 ...

Страница 245: ... A Scan Enter barcode B Scan Insertion2DataPosition barcode C Scan parameters from Hexadecimal Decimal table D Scan OK barcode E Scan End barcode Configuration Length Default Setting 2 NULL Procedure A Scan Enter barcode B Scan Insertion1Data barcode C Scan parameters from Hexadecimal Decimal table D Scan OK barcode E Scan End barcode Configuration Range Default Setting 0 80 0 ...

Страница 246: ...11 Insertion2Data To set up data2 to be inserted M38 Configuration Length Default Setting 2 NULL Procedure A Scan Enter barcode B Scan Insertion2Data barcode C Scan parameters from Hexadecimal Decimal table D Scan OK barcode E Scan End barcode ...

Страница 247: ...ZEND 7 25 Code128 7 25 1 Read Whether the barcode can be scanned QZG0 Disable QZG1 Enable 7 25 2 Append To set up whether able to scan multiple related barcodes and decode them into a complete Code128 barcode MZL0 Disable MZL1 Enable ...

Страница 248: ...1 Enable 7 25 4 Min Code Length To set up the minimum length of the barcode less than this length barcode cannot be scanned IZH Procedure A Scan Enter barcode B Scan Min Code Length barcode C Scan parameters from Hexadecimal Decimal table D Scan OK barcode E Scan End barcode Configuration Range Default Setting 0 80 0 ...

Страница 249: ...can parameters from Hexadecimal Decimal table D Scan OK barcode E Scan End barcode 7 25 6 Truncate Leading To set up the number of digits to be omitted from the beginning of the barcode K3O Procedure A Scan Enter barcode B Scan Truncate Leading barcode C Scan parameters from Hexadecimal Decimal table D Scan OK barcode E Scan End barcode Configuration Range Default Setting 0 80 80 Configuration Ran...

Страница 250: ...e end of the barcode M3Q Procedure A Scan Enter barcode B Scan Truncate Ending barcode C Scan parameters from Hexadecimal Decimal table D Scan OK barcode E Scan End barcode 7 25 8 Truncate Zero Whether to omit 0 from the beginning of the barcode O3S0 Disable O3S1 Enable Configuration Range Default Setting 0 80 0 ...

Страница 251: ...e C Scan parameters from Hexadecimal Decimal table D Scan OK barcode E Scan End barcode 7 25 10 Insertion1Data To set up data1 to be inserted J3W Configuration Range Default Setting 0 80 0 Configuration Length Default Setting 2 NULL Procedure A Scan Enter barcode B Scan Insertion1Data barcode C Scan parameters from Hexadecimal Decimal table D Scan OK barcode E Scan End barcode ...

Страница 252: ...e C Scan parameters from Hexadecimal Decimal table D Scan OK barcode E Scan End barcode 7 25 12 Insertion2Data To set up data2 to be inserted O40 Configuration Range Default Setting 0 80 0 Configuration Length Default Setting 2 NULL Procedure A Scan Enter barcode B Scan Insertion2Data barcode C Scan parameters from Hexadecimal Decimal table D Scan OK barcode E Scan End barcode ...

Страница 253: ...Enable 7 26 2 Min Code Length To set up the minimum length of the barcode less than this length barcode cannot be scanned PZO Procedure A Scan Enter barcode B Scan Min Code Length barcode C Scan parameters from Hexadecimal Decimal table D Scan OK barcode E Scan End barcode Configuration Range Default Setting 0 80 0 ...

Страница 254: ...can parameters from Hexadecimal Decimal table D Scan OK barcode E Scan End barcode 7 26 4 Truncate Leading To set up the number of digits to be omitted from the beginning of the barcode EVI Procedure A Scan Enter barcode B Scan Truncate Leading barcode C Scan parameters from Hexadecimal Decimal table D Scan OK barcode E Scan End barcode Configuration Range Default Setting 0 80 80 Configuration Ran...

Страница 255: ...e end of the barcode GVK Procedure A Scan Enter barcode B Scan Truncate Ending barcode C Scan parameters from Hexadecimal Decimal table D Scan OK barcode E Scan End barcode 7 26 6 Truncate Zero Whether to omit 0 from the beginning of the barcode 9VM0 Disable 9VM1 Enable Configuration Range Default Setting 0 80 0 ...

Страница 256: ...e C Scan parameters from Hexadecimal Decimal table D Scan OK barcode E Scan End barcode 7 26 8 Insertion1Data To set up data1 to be inserted DVQ Configuration Range Default Setting 0 80 0 Configuration Length Default Setting 2 NULL Procedure A Scan Enter barcode B Scan Insertion1Data barcode C Scan parameters from Hexadecimal Decimal table D Scan OK barcode E Scan End barcode ...

Страница 257: ...e C Scan parameters from Hexadecimal Decimal table D Scan OK barcode E Scan End barcode 7 26 10 Insertion2Data To set up data2 to be inserted HVU Procedure A Scan Enter barcode B Scan Insertion2Data barcode C Scan parameters from Hexadecimal Decimal table D Scan OK barcode E Scan End barcode Configuration Range Default Setting 0 80 0 Configuration Length Default Setting 2 NULL ...

Страница 258: ...3 JapanesePost IZQ4 KIXPost NetherlandsPost IZQ5 PlanetCode PLA IZQ6 Postnet POS IZQ7 BritishPost IZQ8 InfoMail BritishPost IZQ9 Postal 4i POS4 IZQA IntelligentMail IM IZQB PostnetB B Fields IZQC Planet Postnet IZQD Planet Postal 4i IZQE Postnet Postal 4i IZQF Planet IM IZQG Postnet IM IZQH Postal 4i IM IZQI PLA POSB B F IZQJ POS4 POSB B F IZQK IM POSB B F ...

Страница 259: ...M IZQN PLA POS4 IM IZQO POS POS4 IM IZQP PLA POS4 POSB B F IZQQ PLA IM POSB B F IZQR POS4 IM POSB B F IZQS PLA POS4 IM POS IZQT PLA POS4 IM POSB B F IZQU CanadianPost 7 27 2 Postnet Tx CheckDigit Whether to send the check digit of Postnet barcode JZR0 Disable JZR1 Enable ...

Страница 260: ...t Bar Output lists the bar patterns in 0123 format NumericN Numeric N Table causes that field to be interpreted as numeric data using the N Table AlphanumericC Alphanumeric C Table causes the field to be interpreted as alphanumeric data using the C Table Refer to the Australian Post Specification Tables CombinationN C Combination C and N Tables causes the field to be interpreted using either the C...

Страница 261: ... AVW JapanesePost CWO PlanetCode AXU Postnet ETK BritishPost EXG Postal4i 9X2 IntelligentMail ATY CanadianPost GWA NetherlandsPost Procedure Type Configuration Range Default Setting AustralianPost 0 80 0 InfoMail 0 80 0 JapanesePost 0 80 0 PlanetCode 0 80 0 Postnet 0 80 0 BritishPost 0 80 0 Postal4i 0 80 0 IntelligentMail 0 80 0 CanadianPost 0 80 0 NetherlandsPost 0 80 0 ...

Страница 262: ...iWaylink Inc 262 Enter End ENTR ZEND A Scan Enter barcode B Scan Truncate Leading barcode C Scan parameters from Hexadecimal Decimal table D Scan OK barcode E Scan End barcode ...

Страница 263: ... JapanesePost EWQ PlanetCode CXW Postnet GTM BritishPost GXI Postal4i BX4 IntelligentMail DU0 CanadianPost 9WC NetherlandsPost Procedure Type Configuration Range Default Setting AustralianPost 0 80 0 InfoMail 0 80 0 JapanesePost 0 80 0 PlanetCode 0 80 0 Postnet 0 80 0 BritishPost 0 80 0 Postal4i 0 80 0 IntelligentMail 0 80 0 CanadianPost 0 80 0 NetherlandsPost 0 80 0 ...

Страница 264: ...iWaylink Inc 264 Enter End ENTR ZEND A Scan Enter barcode B Scan Truncate Ending barcode C Scan parameters from Hexadecimal Decimal table D Scan OK barcode E Scan End barcode ...

Страница 265: ...nPost InfoMail JapanesePost DTA0 Disable FS40 Disable FW00 Disable DTA1 Enable FS41 Enable FW01 Enable PlanetCode Postnet BritishPost GWS0 Disable EXY0 Disable 9TO0 Disable GWS1 Enable EXY1 Enable 9TO1 Enable Postal4i IntelligentMail CanadianPost 9XK0 Disable DX60 Disable FU20 Disable 9XK1 Enable DX61 Enable FU21 Enable ...

Страница 266: ...iWaylink Inc 266 Enter End ENTR ZEND NetherlandsPost BWE0 Disable BWE1 Enable ...

Страница 267: ... 9WU PlanetCode HY0 Postnet BTQ BritishPost BXM Postal4i FX8 IntelligentMail HU4 CanadianPost DWG NetherlandsPost Procedure Type Configuration Range Default Setting AustralianPost 0 80 0 InfoMail 0 80 0 JapanesePost 0 80 0 PlanetCode 0 80 0 Postnet 0 80 0 BritishPost 0 80 0 Postal4i 0 80 0 IntelligentMail 0 80 0 CanadianPost 0 80 0 NetherlandsPost 0 80 0 ...

Страница 268: ...iWaylink Inc 268 Enter End ENTR ZEND A Scan Enter barcode B Scan Insertion1DataPosition barcode C Scan parameters from Hexadecimal Decimal table D Scan OK barcode E Scan End barcode ...

Страница 269: ... PlanetCode AY2 Postnet DTS BritishPost DXO Postal4i HXA IntelligentMail AU6 CanadianPost FWI NetherlandsPost Type Configuration Length Default Setting AustralianPost 2 NULL InfoMail 2 NULL JapanesePost 2 NULL PlanetCode 2 NULL Postnet 2 NULL BritishPost 2 NULL Postal4i 2 NULL IntelligentMail 2 NULL CanadianPost 2 NULL NetherlandsPost 2 NULL ...

Страница 270: ...iWaylink Inc 270 Enter End ENTR ZEND Procedure A Scan Enter barcode B Scan Insertion1Data barcode C Scan parameters from Hexadecimal Decimal table D Scan OK barcode E Scan End barcode ...

Страница 271: ...tCode CY4 Postnet FTU BritishPost FXQ Postal4i AXC IntelligentMail CU8 CanadianPost HWK NetherlandsPost Procedure A Scan Enter barcode Type Configuration Range Default Setting AustralianPost 0 80 0 InfoMail 0 80 0 JapanesePost 0 80 0 PlanetCode 0 80 0 Postnet 0 80 0 BritishPost 0 80 0 Postal4i 0 80 0 IntelligentMail 0 80 0 CanadianPost 0 80 0 NetherlandsPost 0 80 0 ...

Страница 272: ...iWaylink Inc 272 Enter End ENTR ZEND B Scan Insertion2DataPosition barcode C Scan parameters from Hexadecimal Decimal table D Scan OK barcode E Scan End barcode ...

Страница 273: ...netCode EY6 Postnet HTW BritishPost HXS Postal4i CXE IntelligentMail EUA CanadianPost AWM NetherlandsPost Procedure Type Configuration Length Default Setting AustralianPost 2 NULL InfoMail 2 NULL JapanesePost 2 NULL PlanetCode 2 NULL Postnet 2 NULL BritishPost 2 NULL Postal4i 2 NULL IntelligentMail 2 NULL CanadianPost 2 NULL NetherlandsPost 2 NULL ...

Страница 274: ...iWaylink Inc 274 Enter End ENTR ZEND A Scan Enter barcode B Scan Insertion2Data barcode C Scan parameters from Hexadecimal Decimal table D Scan OK barcode E Scan End barcode ...

Страница 275: ...le PZX1 Enable 7 28 2 Min Code Length To set up the minimum length of the barcode less than this length barcode cannot be scanned QZY Procedure A Scan Enter barcode B Scan Min Code Length barcode C Scan parameters from Hexadecimal Decimal table D Scan OK barcode E Scan End barcode Configuration Range Default Setting 2 80 4 ...

Страница 276: ...can parameters from Hexadecimal Decimal table D Scan OK barcode E Scan End barcode 7 28 4 Truncate Leading To set up the number of digits to be omitted from the beginning of the barcode GY8 Procedure A Scan Enter barcode B Scan Truncate Leading barcode C Scan parameters from Hexadecimal Decimal table D Scan OK barcode E Scan End barcode Configuration Range Default Setting 2 80 80 Configuration Ran...

Страница 277: ...e end of the barcode 9YA Procedure A Scan Enter barcode B Scan Truncate Ending barcode C Scan parameters from Hexadecimal Decimal table D Scan OK barcode E Scan End barcode 7 28 6 Truncate Zero Whether to omit 0 from the beginning of the barcode BYC0 Disable BYC1 Enable Configuration Range Default Setting 0 80 0 ...

Страница 278: ...e C Scan parameters from Hexadecimal Decimal table D Scan OK barcode E Scan End barcode 7 28 8 Insertion1Data To set up data1 to be inserted FYG Configuration Range Default Setting 0 80 0 Configuration Length Default Setting 2 NULL Procedure A Scan Enter barcode B Scan Insertion1Data barcode C Scan parameters from Hexadecimal Decimal table D Scan OK barcode E Scan End barcode ...

Страница 279: ...e C Scan parameters from Hexadecimal Decimal table D Scan OK barcode E Scan End barcode 7 28 10 Insertion2Data To set up data2 to be inserted AYK Procedure A Scan Enter barcode B Scan Insertion2Data barcode C Scan parameters from Hexadecimal Decimal table D Scan OK barcode E Scan End barcode Configuration Range Default Setting 0 80 0 Configuration Length Default Setting 2 NULL ...

Страница 280: ...iWaylink Inc 280 Enter End ENTR ZEND 7 29 Korea Post 7 29 1 Read Whether the barcode can be scanned U000 Disable U001 Enable 7 29 2 Tx Checkdigit Whether to send check digit X030 Disable X031 Enable ...

Страница 281: ...meters from Hexadecimal Decimal table D Scan OK barcode E Scan End barcode 7 29 4 Max Code Length To set up the maximum length of the barcode longer than this length barcode cannot be scanned W02 Procedure A Scan Enter barcode B Scan Max Code Length barcode C Scan parameters from Hexadecimal Decimal table D Scan OK barcode E Scan End barcode Configuration Range Default Setting 2 80 4 Configuration...

Страница 282: ...n parameters from Hexadecimal Decimal table D Scan OK barcode E Scan End barcode 7 29 6 Truncate Ending To set up the number of digits to be omitted from the end of the barcode ESU Procedure A Scan Enter barcode B Scan Truncate Ending barcode C Scan parameters from Hexadecimal Decimal table D Scan OK barcode E Scan End barcode Configuration Range Default Setting 0 80 0 Configuration Range Default ...

Страница 283: ...barcode GSW0 Disable GSW1 Enable 7 29 8 Insertion1DataPosition To set up the position to insert data1 9SY Procedure A Scan Enter barcode B Scan Insertion1DataPosition barcode C Scan parameters from Hexadecimal Decimal table D Scan OK barcode E Scan End barcode Configuration Range Default Setting 0 80 0 ...

Страница 284: ... A Scan Enter barcode B Scan Insertion2DataPosition barcode C Scan parameters from Hexadecimal Decimal table D Scan OK barcode E Scan End barcode Configuration Length Default Setting 2 NULL Procedure A Scan Enter barcode B Scan Insertion1Data barcode C Scan parameters from Hexadecimal Decimal table D Scan OK barcode E Scan End barcode Configuration Range Default Setting 0 80 0 ...

Страница 285: ...11 Insertion2Data To set up data2 to be inserted GT4 Procedure A Scan Enter barcode B Scan Insertion2Data barcode C Scan parameters from Hexadecimal Decimal table D Scan OK barcode E Scan End barcode Configuration Length Default Setting 2 NULL ...

Страница 286: ...ing AIM Telepen output the scanner reads symbol with start stop pattern 1 and decodes them as standard full ASCII start stop pattern 1 Original When Original Telepen Output is selected the scanner reads symbols with start stop pattern 1 and decodes them as compressed numeric with optional full ASCII start stop pattern 2 CQC0 AIM CQC1 Original ...

Страница 287: ...meters from Hexadecimal Decimal table D Scan OK barcode E Scan End barcode 7 30 4 Max Code Length To set up the maximum length of the barcode longer than this length barcode cannot be scanned EQE Procedure A Scan Enter barcode B Scan Max Code Length barcode C Scan parameters from Hexadecimal Decimal table D Scan OK barcode E Scan End barcode Configuration Range Default Setting 1 60 1 Configuration...

Страница 288: ...n parameters from Hexadecimal Decimal table D Scan OK barcode E Scan End barcode 7 30 6 Truncate Ending To set up the number of digits to be omitted from the end of the barcode J62 Procedure A Scan Enter barcode B Scan Truncate Ending barcode C Scan parameters from Hexadecimal Decimal table D Scan OK barcode E Scan End barcode Configuration Range Default Setting 0 60 0 Configuration Range Default ...

Страница 289: ...barcode L640 Disable L641 Enable 7 30 8 Insertion1DataPosition To set up the position to insert data1 N66 Procedure A Scan Enter barcode B Scan Insertion1DataPosition barcode C Scan parameters from Hexadecimal Decimal table D Scan OK barcode E Scan End barcode Configuration Range Default Setting 0 60 0 ...

Страница 290: ... A Scan Enter barcode B Scan Insertion2DataPosition barcode C Scan parameters from Hexadecimal Decimal table D Scan OK barcode E Scan End barcode Configuration Length Default Setting 2 NULL Procedure A Scan Enter barcode B Scan Insertion1Data barcode C Scan parameters from Hexadecimal Decimal table D Scan OK barcode E Scan End barcode Configuration Range Default Setting 0 60 0 ...

Страница 291: ...11 Insertion2Data To set up data2 to be inserted K6C Procedure A Scan Enter barcode B Scan Insertion2Data barcode C Scan parameters from Hexadecimal Decimal table D Scan OK barcode E Scan End barcode Configuration Length Default Setting 2 NULL ...

Страница 292: ...by a symbol for GS1 barcode BCG0 Disable BCG1 Enable 7 31 2 AppIDConChar To set the symbol which is to separate AppID CCH Procedure A Scan Enter barcode B Scan AppIDConChar barcode C Scan parameters from Hexadecimal Decimal table D Scan OK barcode E Scan End barcode Configuration Length Default Setting 1 ...

Страница 293: ...content of FNC1 DCI0 Disable DCI1 Enable 7 31 4 FNC1Char To set the content of FNC1 ECJ Procedure A Scan Enter barcode B Scan FNC1Char barcode C Scan parameters from Hexadecimal Decimal table D Scan OK barcode E Scan End barcode Configuration Length Default Setting 1 GS 0x1D ...

Страница 294: ... Msi 2 g Gs1DataBar 2 y Gs1DataBarLimited 2 Gs1DataBarExpanded 2 CodablockA 2 V CodablockF 2 q Pdf417 2 r MicroPdf417 2 R Tlc39 2 T QRCode 2 s DataMatrix 2 w MaxiCode 2 x AztecCode 2 z ChineseSensible HanXinCode 2 H Codabar 2 a Code39 2 b Code32 2 Interleaved2of5 2 e Nec2of5 2 Y Code93 2 i Straight2of5 2 f Matrix2of5 2 m Code11 2 h Code128 2 j Gs1128 2 I ...

Страница 295: ... End ENTR ZEND AustralianPost 2 A InfoMail 2 JapanesePost 2 J KIXPost NetherlandsPost 2 K PlanetCode 2 L Postnet 2 P BritishPost 2 B Postal4i 2 N IntelligentMail 2 M CanadianPost 2 C ChinaPost2of5 2 Q KoreaPost 2 Telepen 2 t ...

Страница 296: ...be indicated according to the setting position by Code Position 99Q UPCA C8U UPCE B9S EAN13 A8S EAN8 H9Y Msi FAM Gs1DataBar AAQ Gs1DataBarLimited CAS Gs1DataBarExpanded A9I CodablockA CAA CodablockF EAC Pdf417 F9E MicroPdf417 H9G Tlc39 GAE QRCode BAI DataMatrix DAK MaxiCode HAO AztecCode E8W ChineseSensible HanXinCode E9M Codabar G9O Code39 98I Code32 ...

Страница 297: ... F9W Straight2of5 AA8 Matrix2of5 BA0 Code11 FA4 Code128 G8Y Gs1128 D8M AustralianPost G8G InfoMail A90 JapanesePost C92 KIXPost NetherlandsPost E94 PlanetCode B9A Postnet F8O BritishPost 998 Postal4i G96 IntelligentMail H8Q CanadianPost D9C ChinaPost2of5 B8K KoreaPost 9AG Telepen ...

Страница 298: ...iWaylink Inc 298 Appendix A Hexadecimal Decimal Table 00 0 01 1 02 2 03 3 04 4 05 5 06 6 07 7 08 8 09 9 0A A 0B B 0C C 0D D ...

Страница 299: ...iWaylink Inc 299 0E E 0F F OK OK ...

Страница 300: ...iWaylink Inc 300 Appendix B ASCII Code Table ...

Страница 301: ...iWaylink Inc 301 Enter End ENTR XEND Appendix C A 306 Dongle Setting 1 System 1 1 Version Show Dongle Version XVER Procedure 1 Scan Enter Barcode 2 Scan Version barcode ...

Страница 302: ...BCdef Status Selection Caps Lock On Caps Lock Off UpperCase ABCdef abcDEF LowerCase abcDEF ABCdef Alt Keypad ABCdef ABCdef 2 2 Num Lock The settings of the numeric keypad the keypad must be selected if the application program only accepts numeric keypad The right hand side of the numeric keys on the keyboard and Num Lock control key must be on 4760 AlphaPad 4761 NumPad ...

Страница 303: ...End ENTR XEND 2 3 Hid Keyboard Layout The function enables the user to specify HID keyboard language HID Keyboard Layout setting 6780 EN 6786 SP 6781 UK 6787 PO 6782 JP 6788 SK 6783 FR 6789 KO 6784 GR 678A TR 6785 IT 678B SF ...

Страница 304: ... 7791 Big5 7793 Sjis 2 5 Transmission Char Delay After setting the number of characters sent into the Delay time 37W Configuration Range Default Setting 0 255 0 Procedure A Scan Enter barcode B Scan Transmission Char Delay barcode C Scan parameters from Hexadecimal Decimal table D Scan OK barcode E Scan End barcode ...

Страница 305: ...tween character 47X Procedure Example A Scan Enter barcode B Scan Transmission Char Gap Time barcode C Scan parameters from Hexadecimal Decimal table D Scan OK barcode E Scan End barcode If configuration is 2 ms the parameter value is 2 ms 1 ms 2 Configuration Range Unit Default Setting 0 255 ms 1 ms 0 ms ...

Страница 306: ... 2 records 57Y Procedure Example A Scan Enter barcode B Scan Transmission Record Gap Time barcode C Scan parameters from Hexadecimal Decimal table D Scan OK barcode E Scan End barcode If configuration is 200 ms the parameter value is 200 ms 10 ms 20 Configuration Range Unit Default Setting 0 2550 ms 10 ms 0 ms ...

Страница 307: ... Delay After setting the number of characters sent into the Delay time 69O Configuration Range Default Setting 0 255 0 Procedure A Scan Enter barcode B Scan Transmission Char Delay barcode C Scan parameters from Hexadecimal Decimal table D Scan OK barcode E Scan End barcode ...

Страница 308: ...tween character 79P Procedure Example A Scan Enter barcode B Scan Transmission Char Gap Time barcode C Scan parameters from Hexadecimal Decimal table D Scan OK barcode E Scan End barcode If configuration is 2 ms the parameter value is 2 ms 1 ms 2 Configuration Range Unit Default Setting 0 255 ms 1 ms 0 ms ...

Страница 309: ... 2 records 89Q Procedure Example A Scan Enter barcode B Scan Transmission Record Gap Time barcode C Scan parameters from Hexadecimal Decimal table D Scan OK barcode E Scan End barcode If configuration is 200 ms the parameter value is 200 ms 10 ms 20 Configuration Range Unit Default Setting 0 2550 ms 10 ms 0 ms ...

Страница 310: ...iWaylink Inc 310 Enter End ENTR XEND 4 Dongle Hexadecimal Decimal table 00 0 01 1 02 2 03 3 04 4 05 5 06 6 07 7 08 8 09 9 0A A 0B B 0C C 0D D ...

Страница 311: ...iWaylink Inc 311 Enter End ENTR XEND 0E E 0F F OK OK ...

Страница 312: ... the 12 digits BLE Mac address 3 Use Terminal to receive scan data if interface is USB COM 4 Plug in the dongle into PC USB port make sure the number of Connecting COM port by Device Manager open the Terminal to connect this connect COM Port 5 Clip the dongle reset below photo to get the 12 digits BLE Mac address BLE Mac 1A15D981C8F4 Note Please control the time within 0 5 seconds when clip the re...

Страница 313: ... digits 000000000000 Procedure 1 Enter Enter setting ENTR 2 Master Scanner Address 7HQ 3 Scan Dongle Hexadecimal Decimal table for input parameters 4 OK Selection confirmed OK 5 End Exit setting XEND Example Set Remote Mac Address to 96A3F11A70DA A Scan Enter barcode B Scan Master Scanner Address barcode C Scan parameters from Hexadecimal decimal barcode table 9 6 A 3 F 1 1 A 7 0 D A OK Set Master...

Отзывы: