WARNING AND ERROR MESSAGES
It incorporates various functions of protective and monitoring system to verify functions and the state of
its electronics. In any case of occurring error, the screen displays the cause of error that is self-explanatory
with audible sound.
The output is connected to a battery with incorrect polarity.
Battery connection is interrupted.
Short-circuit of the output termination.
The voltage of the input terminal is lower or higher than the setting limit.
The voltage is higher than which is set. Please check the number of cells in the
battery pack.
The voltage is higher than which is set. Please check the number of cells in the
battery pack.
Voltage of one cell in the battery pack is too low, please check the voltage of each
cell.
Voltage of one cell in the battery pack is too high; please check the voltage of each
cell.
Wrong connection of the connector detected; please check the connector and cable.
The internal temperature of the unit goes too high. Cool down the unit.
Output power is over tha Max Limit value.
Output current is over tha Max Limit value.
WARRANTY AND SERVICE
We guarantee this product to be free of manufacturing and assembly defects for a period of one year
from the time of purchase. The warranty only applies to material or operational defects, which are present
at the time of purchase. During that period, we will repair or replace free of service charge for products
deemed defective due to those causes.
You will be required to produce proof of purchase (invoice or receipt). This warranty is not valid for any
damage or subsequent damage arising as a result of misuse, modification or as a result of failure to
observe the procedures outlined in this manual.
It incorporates a various functions of protective and monitoring the system to
verify functions and the state of its electronics. In any case of occurring error, the
screen displays the cause of error that is self- explanatory with audible sound.