CHARGE-TO-DISCHARGE & DISCHARGE-TO-CHARGE CYCLE NIMH/NICD BATTERY
Set the sequence on the left and the number of cycle on the right. You can use this function
for balancing, refreshing and break-in the battery. To avoid rising temperature of the battery,
there will a brief cool-off period that already fixed at “User setting” after each charge and
discharge process. The cycling number ranges from 1 to 5.
To stop the process, press
Batt type/Stop
key once. You can change the discharge
or charge current by pressing
Enter
key once during the process. The audible sound
indicates you the end of process.
At the end of the process, you can see charged or discharged electric capacities of the
battery at each cyclic process.
By pressing
INC or DEC
button, the screen shows the result of each cycle in order.
NI-MH/NI-CD BATTERY SECOND CHARGE
The charger has the new program which can charge the battery for second time (The battery which was
notused for a long time or the old battery or the battery which cannot reach Max Voltage after first charge).
In t his way, this mode can make the battery's capacity to the standard value and make the battery's life longer.
Set the charge current on the left, set the second charge time on the right. The program will start after
Enter
being pressed during 3 seconds and will stop after pressing
Batt type/Stop
. Users can change the
charge/discharge current by
Enter
button during the process.
PB (LEAD-SULPHURIC ACID) BATTERY PROGRAM
This is programmed for charging Pb (lead-acid) battery with nominal voltage from 2 to 12V. Pb batteries are totally
different from NiCd or NiMH batteries. They can only deliver relatively lower current compare to their capacity,
and similar restrictions definitely apply to charge. So the optimal charge current will be 1/10 of the capacity. Pb
batteries must not be charged rapidly. Always follow the instruction is supplied by the manufacturer of battery.
When you are willing to alter the parameter value in the program, press Enter key to make it blink then
change the value with
INC or DEC
key. The value will be stored by pressing Enter key once.
CHARGING PB BATTERY
Set up the charge current on the left and the nominal voltage of the battery on
the right. The charge current ranges from 0.1 to 6.0A and the voltage should be
matched with the battery being charged.
Start the charge process by pressing
Enter
key for more than 3 seconds.
The screen displays the state of charging process. To stop charging forcibly, press
Batt type/Stop
key once.
The audible sound indicates you at the end of the process.
NiMH[0] CYCLE
DCHG>CHG 3
Pb[0] CHARGE
4.0A 12.0V(6P)
ENGLISH
12
FRAN
Ç
AIS