iDrive2 inverters Function Parameters
45
Function
code
Name
Detailed instruction of parameters
Default
value
Modify
code 3
P07.24
Factory bar
code 4
0x0000~0xFFFF
●
P07.25
Factory bar
code 5
0x0000~0xFFFF
●
P07.26
Factory bar
code 6
0x0000~0xFFFF
●
P07.27
Current fault
type
0:No fault
4:OC1
5:OC2
6:OC3
7:OV1
8:OV2
9:OV3
10:UV
11:Motor overload (OL1)
12:The inverter overload (OL2)
15:Overheat of the rectifier module (OH1)
16:Overheat fault of the inverter module (OH2)
17:External fault (EF)
18:485 communication fault (CE)
21:EEPROM operation fault (EEP)
22:PID response offline fault (PIDE)
24:Run time arrival (END)
25:Electrical overload (OL3)
36: Undervoltage fault (LL)
●
P07.28
Previous
fault type
●
P07.29
Previous 2
fault type
●
P07.30
Previous 3
fault type
●
P07.31
Previous 4
fault type
●
P07.32
Previous 5
fault type
●
P07.33
Current fault
running
frequency
0.00Hz
●
P07.34
Ramp
reference
frequency at
current fault
0.00Hz
●
P07.35
Output
voltage at
current fault
0V
●