17
Dismantling
A.
• Turn the electricity OFF.
• Close the valves.
12
Use appropriate vessels to collect oil
spillage when removing and opening
the pump
B.
• Loosen the screws 701 with an allen key.
C.
• Mount the guiding pins into the connecting
frame.
D.
• Pull out the pump from the connecting frame
together with the magnetic coupling. Beware