25
INS
TALL
AT
O
R
US
ER
MAINTEN
AN
CE
- Temperature adjustment at domestic water flow
of 7l/min. with inlet temperature of 15°C.
- Fume temperature values refer to an air inlet
temperature of 15°C.
- The data relevant to domestic hot water per-
formance refer to a dynamic inlet pressure of
2 bar and an inlet temperature of 15°C; the
values are measured directly at the boiler outlet
considering that to obtain the data declared
mixing with cold water is necessary.
- The max. sound level emitted during boiler
operation is < 55dBA. The sound level value is
referred to semianechoic chamber tests with
boiler operating at max. heat output, with
extension of fume exhaust system according
to product standards.
3.18 TECHNICAL DATA.
Zeus 24 kW
Zeus 28 kW
Nominal heating power
kW (kcal/h)
25,5 (21934)
29,8 (25644)
Minimum heating power
kW (kcal/h)
10,5 (9048)
12,6 (10799)
Nominal heating power (useful)
kW (kcal/h)
24,0 (20640)
28,0 (24080)
Minimum heating power (useful)
kW (kcal/h)
9,3 (7998)
11,0 (9460)
Useful thermal efficiency at nominal output
%
94,1
93,9
Useful thermal efficiency at 30% nominal output
%
90,4
90,6
Heat loss at case with burner On/Off
%
0,40 / 0,89
0,60 / 0,62
Heat loss at flue with burner On/Off
%
5,50 / 0,03
5,50 / 0,01
Heating circuit max. working pressure
bar
3
3
Heating circuit max. working temperature
°C
90
90
Adjustable heating temperature
°C
35 - 85
35 - 85
Total volume system heating expansion tank
l
7,7
7,7
Heating expansion tank pre-charge
bar
1
1
Generator water capacity
l
3,6
4,1
Head available with flow rate 1000/h
kPa (m H
2
O)
24,7 (2,52)
33,4 (3,41)
Hot water production available heat output
kW (kcal/h)
24,0 (20640)
28,0 (24080)
Domestic hot water adjustable temperature
°C
20 - 60
20 - 60
Domestic circuit flow limiter at 2 bar
l/min
9,2
11,6
Domestic circuit min. pressure (dynamic
bar
0,3
0,3
Domestic circuit max. working pressure
bar
8
8
Specific capacity (∆T 30°C)
l/min
13,5
14,5
Drawing capacity in continuous duty (∆T 30°C)
l/min
11,5
13,4
Weight of full boiler
kg
100,1
104,6
Weight of empty boiler
kg
54
58
Electric attachment
V/Hz
230/50
230/50
Nominal absorption
A
0,7
0,73
Installed electric power
W
140
145
Power absorbed by circulation pump
W
81,7
85,6
Power absorbed by fan
W
32,8
37,6
Equipment electrical system protection
-
IPX4D
IPX4D
NO
X
class
-
3
3
NO
X
weighted
mg/kWh
134
113
CO weighted
mg/kWh
111
104
Type of appliance
C12 /C32 / C42 / C52 / C82 / B22 / B32
Category
II2H3+
Содержание ZEUS 24 Superior
Страница 1: ...ZEUS 24 28 kW IE Instruction booklet and warning 1 038761ENG...
Страница 26: ......
Страница 27: ......