Technical documentation
Technical documentation
STZS ed. 06/03
31
ZEUS SUPERIOR
COMBUSTION PARAMETERS
(with combustion air temperature 15 ºC)
ZEUS 21 Superior
ZEUS 24 Superior
ZEUS 27 Superior
G20 G30 G31 G20 G30 G31 G20 G30 G31
Rated power flue gas mass flow
rate
kg/h
56 65 65 67 70 72 73 83 82
Minimum power flue gas mass
flow rate
kg/h
57 71 71 69 77 76 81 89 89
CO
2
at rated power
% 6,8 6,7 6,7 6,5 7,1 6,9 6,5 6,8 6,7
CO
2
at minimum power
% 2,6 2,4 2,4 2,4 2,5 2,5 2,5 2,7 2,8
CO at 0% O
2
at rated power
ppm
117 75 54 90 59 36 64 81 33
CO at 0% O
2
at minimum power
ppm 70 106 128 95 137 120 72 95 122
No
x
at 0% O
2
at rated power
ppm 138 213 180 174 197 191 152 225 201
No
x
at 0% O
2
at minimum power ppm 88 102 95 89 110 99 70 104 102
Flue gas temperature at rated
power
ºC 123 122 125 120 125 131 124,4
116,7
116,0
Flue gas temperature at minimum
power
ºC 96 93 101 93 103 102
101,2
95,6 99,2
ZEUS 21 Superior HEAT OUTPUT ADJUSTMENTS
NATURAL GAS (G20)
BUTANE (G30)
PROPANE (G31)
Heat
output
(Kcal/h)
Heat
output
(kW)
Burner gas
flow rate
(m
3
/h)
Burner nozzle
pressure
(mbar)
(mm H
2
O)
Burner gas
flow rate
(m
3
/h)
Burner nozzle
pressure
(mbar)
(mm H
2
O)
Burner gas
flow rate
(m
3
/h)
Burner nozzle
pressure
(mbar)
(mm H
2
O)
21000 24,42
2,82 10,4 106 2,10 28,3
288 2,07 36,3
370
20000 23,26
2,69 9,5 97
2,00 25,9
264 1,97 33,6
343
19000 22,09
2,56 8,7 89
1,91 23,6
241 1,88 31,0
316
18000 20,93
2,44 7,9 81
1,82 21,4
219 1,79 28,5
291
17000 19,77
2,31 7,2 73
1,72 19,4
198 1,70 26,1
266
16000 18,60
2,19 6,5 66
1,63 17,5
178 1,60 23,7
242
15000 17,44
2,06 5,8 59
1,53 15,6
159 1,51 21,4
218
14000 16,28
1,93 5,1 52
1,44 13,9
142 1,42 19,2
196
13000 15,12
1,81 4,5 46
1,35 12,3
125 1,33 17,0
174
12000 13,95
1,68 3,9 40
1,25 10,8
110 1,23 14,9
152
11000 12,79
1,55 3,4 35
1,16 9,3 95
1,14 12,9 131
10000 11,63
1,42 2,9 29
1,06 8,0 81
1,04 10,9 111
9000
10,47 1,29 2,4
24 0,96 6,8
69 0,95 8,9
91
8000
9,30 1,16 1,9
20 0,86 5,6
57 0,85 7,0
72