3.17 CASING REMOVAL.
To facilitate boiler maintenance the casing can
be completely removed as follows:
• Lower grid (Fig. 3-4a).
1) Loosen the screws (2).
2) Remove the grid (1).
• Front panel (Fig. 3-4b).
3) Remove the cover caps (3) and loosen the
screws (4).
4) Tilt the control panel (5) towards you.
• Casing (Fig. 3-4c).
5) Remove the screws (6) that lock the front
casing (7) and the two sides (9).
6) Pull the front casing slightly (7) in the lower
part towards yourself and push upwards at
the same time.
7) Loosen the screws (8) on the sides (9).
8) Remove the sides by pulling them towards
you in order to extract them from the 2 rear
seats (Ref. X).