2-1
21
INS
TALLER
US
ER
MAINTEN
AN
CE TECHNI
CI
AN
2
USE AND MAINTENANCE
INSTRUCTIONS
2.1 CLEANING AND MAINTENANCE.
Attention:
to preserve the boiler’s integrity and
keep the safety features, performance and relia-
bility which distinguish it unchanged over time,
maintenance operations must be carried out on a
yearly basis in compliance with that stated in the
“annual check and maintenance of the appliance”
section, in compliance with national, regional, or
local standards in force.
2.2 GENERAL WARNINGS.
Never expose the wall-mounted boiler to direct
vapours from a cooking surface.
Use of the boiler by unskilled persons or children
is strictly prohibited.
For safety purposes, check that the air intake/
flue exhaust terminals (if fitted) are not blocked.
If temporary shutdown of the boiler is required,
proceed as follows:
a) drain the heating system if anti-freeze is not
used;
b) shut-off all electrical, water and gas supplies.
In the case of work or maintenance to structures
near ducting or devices for flue extraction and the
relative accessories, switch off the appliance and
on completion of the operations make sure that
an authorised company verifies the efficiency of
the ducting or the devices.
Never clean the appliance or connected parts
with easily flammable substances.
Never leave containers or flammable substances
in the same environment as the appliance.
•
Attention:
the use of components involving use
of electrical power requires some fundamental
rules to be observed:
- do not touch the appliance with wet or moist
parts of the body; do not touch when bare-
foot;
- never pull electrical cables or leave the appli-
ance exposed to weathering (rain, sunlight,
etc.);
- the appliance power cable must not be re-
placed by the user;
- if the cable is damaged, switch off the ap-
pliance and solely contact an authorised
company to replace it;
- if the appliance is not to be used for a certain
period, disconnect the main power switch.
N.B.:
the temperatures indicated by the display
have a tolerance of +/- 3°C due to environmental
conditions that cannot be attributed to the boiler.
At the end of its service life the appliance must
not be disposed of like normal household waste
nor abandoned in the environment, but must
be removed by a professionally authorised
company. Contact the manufacturer for disposal
instructions.
2.3 CONTROL PANEL.
Key:
1 - Domestic hot water temperature selector
2 - Reset button
3 - Summer / Winter Button
4 - Central heating temperature selector
5 - Information button
6 - Off / Stand-by / On button
7 - Boiler manometer
8 - DHW production phase operating mode
active
9 - Boiler in block requiring unblock via
“RESET” button
10 - Flame presence symbol and relative
power scale
11 - Functioning in summer mode
12 - Functioning in winter mode
13 - Room central heating phase operating
mode active
14 - Temperature indicator, boiler info and
error codes
15 - Boiler in Stand-by mode
16 - Presence of external connected devices
17 - Solar function active
18 - Functioning with external temperature
probe active (optional)
19 - Boiler connected to remote control
V2
(optional)
20 - Not used on this model