Technical Documentation
Technical Documentation
Technical Documentation
Technical Documentation
Flue pressure switch contact control
e integrated board checks switching of the flue pressure switch contact resulting from fan operation
(NO contact)
Flue pressure switch contact control
e integrated board checks the correct position of the flue pressure switch
(NC contact)
EOLO Eco kW operating sequence.
Central heating phase Domestic hot water phase
Power on
Main selector switch on WINTER
Integrated board operation enabled
Closing of the main selector switch contacts
(WINTER position)
enables operation in the central heating phase
Powering the circulator and 3-way diverter valve
e integrated board powers the boiler circulator and the electric
3-way diverter valve, the valve is moved into the heating position
Power on
Main selector switch on SUMMER or WINTER
Closing of the d.h.w. flow switch
Running of domestic hot water
System pressure micro switch closes
e pressure in the primary circuit higher than the minimum cut-off value, causes the system pressure switch contact to close
ò
ò
ò
Gas valve coils powered
Enabled by the overheating safety thermostat, the integrated board powers the gas valve coils
ò
Burner ignition (automatic slow ignition)
e integrated board sends the slow ignition current to the modulation coil
Flame detection
By means of the ionisation electrode, the integrated board detects burner ignition
ò ò
ò ò
ò ò
ò ò
Integrated board operation enabled
Closing of the main selector switch contacts
(SUMMER position)
enables operation in the domestic hot water phase
Closing of the Room thermostat switch / CAR operation
request
Request of the room thermostat or CAR
(if mounted)
detects
conditions that require operation in the central heating phase
Ignition electrodes powered
e integrated board powers the ignition electrodes
ò
ò
Boiler working
e burner works at a power that varies according to the type of request, to the adjustments/settings made and to the temperatures
detected by the NTC probes
ò
Powering the circulator and 3-way diverter valve
e integrated board powers the boiler circulator and the electric
3-way diverter valve, the valve is moved into the d.h.w. position
ò
Fan powered
e integrated board powers the fan