3.7 SETTINGS MENU.
Press the “Menu” button to access a list of
variables that enable you to customise use of
the system.
To browse the menus, which can be accessed by
pressing the relative “RH” or “LH” context but-
tons, scroll through the sub-menus displayed by
turning the main switch. Press the said selector to
select the one highlighted. By pressing repeatedly,
MAIN MENU
Menu item
Description
Set Point Zone
Defines the operating parameters to manage the zone
Set Point DHW
Defines the operation parameters in domestic circuit mode
Time and Program
Defines the date/time and time operating ranges
Information
Display system operating data
Historical alarm code
Displays the list of the last 10 anomalies
Service
Password protected menu dedicated to a qualified technician
Language
Defines the remote panel operation language
Menù Set Point Zone
Menu item
Description
Range
Default
Customised
value
Set comfort heat.
Room temperature in central heating zone Comfort mode
15 ÷ 35 °C
20
Set economy heat.
Room temperature in central heating zone Economy mode
5 ÷ 25 °C
17
Set flow heat.
Flow temperature in room zone central heating mode
(*)
20 ÷ 60 °C
40
Offset flow heat.
Offset temperature for central heating zone
- 15 ÷ + 15°C
0
Set comfort cool.
Room temperature in cooling zone Comfort mode
15 ÷ 35 °C
25
Set economy cool.
Room temperature in cooling zone Economy mode
15 ÷ 35 °C
28
Set flow cool.
Flow temperature in room zone cooling mode
(*)
4 ÷ 25 C
8
Offset flow cool.
Offset temperature for cooling zone
-15 ÷ + 15 °C
0
(*) N.B.:
the range depends on the configuration in the Cooling / central heating thermoregulation menu.
Menù Set Point DHW
Menu item
Description
Range
Default
Customised
value
Set Comfort
DHW storage temperature in Comfort phase
30 ÷ 60 °C
50
Set Economy
DHW storage temperature in Economy phase
30 ÷ 45 °C
30
Menù Time and Program
Menu item
Description
Range
Default
Customised
value
Date and Time
Current date and time setting
Time slots
Defines the time range for operation in Comfort and Economy mode
Program Zone
Time programming for controlled zone
Mon - Fri
Cal 1
Sat - Sun
Cal 3
Program DHW
DHW operation time programming
Mon - Sun
Cal 1
Program Holiday
Defines the period during which the system disables both hot water
heating and room central heating and/or cooling functions.
At the end of the set days, the previously active functions will be reset.
Disabled
Information Menu
Menu item
Description
you can scroll down the menu levels and go back
to a previous level by pressing the “Back” context
button. To exit the menu completely, press the
“Esc” button, which will take you back to the
initial page of normal operation.
To confirm the parameter change, press the
main switch.
Menu
Esc
Back
Set Point Zone
[ ... ]
Time and program
[ ... ]
Information
[ ... ]
Historical alarm code
[ ... ]
Service
[ ... ]
3-8
Hereunder is a list of available menus.