2.6 PARAMETERS AND INFORMATION
MENU
By pressing the button “
”, the “Information menu” is activat-
ed for at least 1 second, displaying some boiler operating parame-
ters.
Press buttons
to scroll through the various parameters.
With the menu active on the indicator (
) the parameter via the
letter “d” plus the number of the parameter that is being displayed
will alternately show.
To view the parameter value, select it by pressing the button .
Press “
” or wait 15 minutes to go back to the previous screen
or exit the menu.
Parameter ID
Description
d 0.0
Not used
d 0.1
Displays the combustion signal
d 0.2
Displays the primary heat exchanger output instant heating flow temperature
d 0.3
Displays the instant output temperature from the DHW exchanger
d 0.4
Displays the values set for central heating set
d 0.5
Displays the values set for DHW set
d 0.6
Displays the external environment temperature (if optional external probe present)
If the temperature is below zero, the value is displayed flashing.
d 0.7
Not used
d 0.8
Displays the system return water temperature
d 0.9
Displays the list of the last five anomalies. Press the “
” button to display the anomalies.
Then press the
keys to scroll the list of anomalies.
d 1.0
Anomaly list reset. Once “d 1.0” is displayed, press the Reset button; deletion is confirmed via the “88” symbols flashing for two
seconds.
d 1.1
Not used
d 1.2
Displays the pump operating speed
d 1.3
Not used
d 1.4
Displays the pump flow rate (lh/100)
d 1.5
Displays the fan operating speed (rpm/100)
d 1.6
Displays the temperature read on the flue probe
d 1.7
Displays the calculated flow temperature
d 1.8
At the end of the screed heater function, displays for how many hours the flow temperature remained at “Top set”
d 1.9
Toggles between the safety software version and the functional software version
d 2.0
Displays the flow temperature of zone two (optional)
d 2.1
Displays the flow temperature of zone three (optional)
d 2.2
Gas valve functioning meter *
d 2.3
Ignition cycle meter *
(*) H-number_H, M-number_M, L-number_L will be displayed alternatively and the corresponding number will be the succession of
the three.
Example: Number_H = 12, Number_M = 34, Number_L = 56 will be displayed as 123456 ( number of hours per d 2.2; number of cycles
per d 2.3)