background image

7

1-2

INS

TALLER

US

ER

MAINTEN

AN

CE TECHNI

CI

AN

1.4  SYSTEM FILLING.

On connection of the storage tank, fill the sys-

tem. Filling is performed at low speed to ensure 

release of air bubbles in the water via the heating 

system vents.

The filling valve must be closed when the pointer 

on the boiler manometer indicates about 1.2 bar 

(see boiler instruction book).

1.5  DOMESTIC HOT WATER STORAGE 

TANK UNIT.

The storage tank unit must be connected to a 

boiler, solar panel system or heat pumps.

Storage tanks are insulated with high-performing 

insulating materials that can limit heat disper-

sion. The insulating material on Inoxstor 200 

and 300 litre models is about 60 mm thick and 

about 80 mm thick on Inoxstor 500 litre model.

-  Boiler protection: this storage tank is manufac-

tured with a stainless steel casing and bottom, 

which guarantees a long life. The assembly 

concepts and welding (T.I.G.) are implemented 

to the minimum detail to ensure maximum 

reliability.

- Efficiency: the coiled heat exchange surface is 

sized to supply large quantities of hot water.

- The storage tank has two seats to include the 

sacrificial anode, which is supplied as standard 

to protect the inner part of the storage tank 

against corrosion; one is on the upper part and 

the other is on the side of the storage tank. 

 

N.B.:

 annually check (e.g. the Authorised 

Technical Assistance centre) efficiency of the 

sacrificial anodes. 

1.6  MAIN COMPONENTS.

Key:

  1  -  Insulating material

  2  -  Sacrificial anode  L = 350 mm ( L = 590 

mm for Inoxstor 500) (optional seat for an 

electronic anode)

  3  -  DHW thermometer

  4  -  Domestic hot water probe

  5  -  Storage tank coil

  6  -  Recirculation fitting (Optional)

  7  -  Storage tank integration resistance 

(optional)

  8  -  Solar panels coil

  9  -  Inspection flange

  10  -  Solar boiler probe

  11  -  Sacrificial anode L = 350 mm (optional 

seat for an electronic anode)

Содержание 3.027746

Страница 1: ...Instruction and recommendation booklet IE INOXSTOR 200 300 500 V2 Storage tank 1 041259ENG ...

Страница 2: ......

Страница 3: ...n it is necessary to comply with the provisions specified in the regulations in force and principles of good practice In compliance with legislation in force the systems must be designed by qualified professionals within the dimensional limits established by the Law Instal lation and maintenance must be performed in compliance with the regulations in force according to the manufacturer s instructi...

Страница 4: ...unit 7 1 6 Main components 7 1 7 Kit available on request 8 2 User and maintenance instructions 9 2 1 Cleaning and maintenance 9 2 2 Functioning 9 2 3 Emptying the storage tank unit 9 2 4 Case cleaning 9 2 5 Decommissioning 9 3 Control and maintenance 10 3 1 Functional layout 10 3 2 Yearly control and maintenance of the storage unit 11 3 3 Storage unit technical data 11 3 4 Product data sheet in c...

Страница 5: ...ection areas In the event of a malfunction fault or incorrect operation disable the storage tank unit and contact an authorised company e g the Au thorised Technical Assistance centre which has specifically trained staff and original spare parts Do not attempt to modify or repair the appliance alone Immergas is to comply with the conditions specified in the conventional warranty contract during th...

Страница 6: ...utlet B2 Domestic hot water probe B12 Storage tank solar probe E15 Storage tank integration resistance optional T DHW thermometer X Distance above ground to fix circulation unit Unused DHW side hydraulic connections are to be closed with hydraulic seal caps All connection fittings must be adequately insu lated to minimise heat dispersion Insulated caps to be applied on unused fittings during insta...

Страница 7: ...g and bottom which guarantees a long life The assembly concepts and welding T I G are implemented to the minimum detail to ensure maximum reliability Efficiency the coiled heat exchange surface is sized to supply large quantities of hot water The storage tank has two seats to include the sacrificial anode which is supplied as standard to protect the inner part of the storage tank against corrosion...

Страница 8: ...uest The storage tank unit is set up for application of an integration resistance to provide the anti freeze function which can be calibrated by a specific thermostat Electronic anode kit The storage tank is set up for the installation of the electronic anode Direct current is made to circulate between the device and the tank to be protected via a special titanium anode screwed on and located insi...

Страница 9: ...ween 60 and 65 C because this temperature guarantees the best performance of the storage tank unit and at the same time ensures maximum hygiene maximum affordability delay in lime scale formation The DHW in the storage tank is heated with the passage of CH solar water which circulates inside the coils inside the storage tank unit itself In all cases the maximum temperature inside the storage tank ...

Страница 10: ...ectronic control unit 3 Circulation solar unit 4 Solar system expansion vessel 5 6 bar safety valve 6 System probe and venting unit 7 Mixer valve 8 Storage unit 9 Storage unit thermometer 10 Inspection flange 11 Domestic hot water connection NTC 10 k hom at 25 C supplied as standard 12 Solar panels probe connection AC Domestic hot water outlet AF Domestic cold water inlet MU Storage unit delivery ...

Страница 11: ... TECHNICAL DATA INOXSTOR 200 INOXSTOR 300 INOXSTOR 500 Hydraulic performances Storage tank unit capacity l 202 6 279 480 3 Domestic hot water side maximum pressure bar 8 8 8 DHW side maximum temperature C 99 99 99 Maximum coil pressure bar 6 6 6 Central heating side maximum temperature C 90 90 90 Empty storage tank unit weight kg 60 7 75 0 101 0 Full storage tank unit weight kg 274 9 366 1 598 9 H...

Страница 12: ... F 81W 203L C INOXSTOR 200 V2 100W 480L C INOXSTOR 500 V2 91W 279L C INOXSTOR 300 V2 INOXSTOR 200 V2 INOXSTOR 500 V2 INOXSTOR 300 V2 A 2017 812 2013 A A B C D E F INSTALLER USER MAINTENANCE TECHNICIAN 3 4 PRODUCT DATA SHEET IN COMPLIANCE WITH REGULATION 812 2013 ...

Страница 13: ...13 ...

Страница 14: ...14 ...

Страница 15: ...15 ...

Страница 16: ...immergas com Immergas S p A 42041 Brescello RE Italy Tel 0522 689011 Fax 0522 680617 Certified company ISO 9001 This instruction booklet is made of ecological paper Cod 1 041259ENG rev ST 003315 000 09 17 Inglese per IRLANDA IE ...

Отзывы: