Page 28
PARAmETER
Description
Regulation
Setting range / Parameters
08
Circuit activated by the request contact IV 3
1
1
Direct circuit
2
Mix circuit 1
3
Mix circuit 2
4
D.h.w.
ALL
All circuits
09
Climatic zone
- 5°C
-20...0°C
10
Building type
2
1
light building
2
normal building
3
heavy building
11
Time for returning to standard display
2 min
OFF
no automatic exit
0,5...5 Min
exit after the set time and automatic return to standard display
12
Mixing valves and circulating pump anti-lock function
ON
ON
activated
OFF
disactivated
13
Errors signalling
ON
OFF
no visualization
ON
visualization activated
14
AUTO-SET function
ON
OFF
automatic sensors setting disactivated
ON
automatic sensors setting activated
18
Temperature cycle
OFF
ON, OFF
activated or disactivated
19
Anti-freeze mode
OFF
OFF
permanent according to par. 5
0,5 - 60
timed minutes
23
Protection code
OFF
0000, ...., 9999
24
Temperature visualization in Fahrenheit degrees
OFF
OFF, ON
RESET
Parameters reset
Do not activate except in case of extreme necessity