3.2  WIRING DIAGRAM.

Key:

  B1  - Flow probe

  B2  - Domestic hot water probe (optional)

  B4  - External probe

 CAR

V2

  - Comando Amico Remoto remote control  

Version 2 (optional)

  DS1  - Display

  E3  - Ignition and detection electrodes

  E4  - Safety thermostat

  F1  - Phase fuse

  M1  - Boiler pump

  M30  - Three-way valve (optional)

  R8  - Storage tank resistance

  S2  - Selector switch functioning

  S3  - Reset block keys

  S4  - Domestic hot water flow switch

  S5  - System pressure switch

  S20  - Room thermostat (optional)

  S21  - Domestic hot water temperature 

increase key

  S22  - Domestic hot water temperature reduce 

key

  S23  - Heating temperature increase key

  S24  - Heating temperature reduce key

The boiler is designed for application of a room 

thermostat (S20), an On/Off room chronother-

mostat, a program timer or a Comando Amico 

Remoto remote control

V2

 (CAR

V2

). Connect 

to clamps 40 - 41 eliminating the jumper X40, 

paying attention not to invert the polarity if the 

CAR

V2

 is installed.

Cylinder unit: the boiler is prepared for the ap-

plication of a storage tank unit, which must be 

connected to clamps 36 and 37 of the bipolar 

terminal board positioned under the sealed 

chamber, eliminating resistance R8.
The connector X3 is present in the boiler but 

must be connected only if the storage tank unit 

is present.
The connector X8 is used for the connection 

of the Virgilio Palmtop in the microprocessor 

software updating operation.

3.3 TROUBLESHOOTING.
N.B.: 

maintenance operations must be carried 

out by an authorised company (e.g. After-Sales 

Technical Assistance Service).
-  Smell of gas. Caused by leakage from gas circuit 

pipelines. Check sealing efficiency of gas intake 

circuit.

- Irregular combustion (red or yellow flame). 

When the burner is dirty or the boiler lamellar 

pack is blocked. Clean the burner or the boiler 

lamellar pack.

- Frequent interventions of the over heating 

safety thermostat. It can depend on the lack 

of water in the boiler, little water circulation 

in the system or blocked pump. Check on the 

manometer that the system pressure is within 

established limits. Check that the radiator val-

ves are not closed and also the functionality of 

the pump.

- The boiler produces condensate. This can be 

caused by obstructions of the chimney or flues 

with height or section not proportioned to the 

boiler. It can also be determined by functioning 

at boiler temperatures that are excessively low. 

In this case, make the boiler run at higher 

temperatures.

- Frequent interventions of the flue safety ther-

mostat This can be caused by obstructions in 

the flue gas circuit. Check the flue. The flue 

may be obstructed or by height or section 

not suitable for the boiler. Ventilation may be 

insufficient (see room ventilation point).

-  Presence of air in the system. Check opening of 

the hood of the special air vent valve (Fig. 1-7). 

Make sure the system pressure and expansion 

vessel pre-charge values are within the set 

limits; the pre-charge value for the expansion 

vessel must be 1.0 bar, and system pressure 

between 1 and 1.2 bar.

- Ignition block and Chimney block. (See par. 

2.6 and 1.5 (electric connection).

  T1  - Low voltage feeder

  T2  - Switch-on transformer

  U1  - Rectifier inside the gas valve 

connector (Only available on 

Honeywell gas valves)

  X40  - Room thermostat jumper

  Y1  - Gas valve

  Y2  - Gas valve modulator

 

1  - User interface

 

2  - N.B.: The user interface is on 

the welding side of the boiler 

board

 

3  - 230 Vac 50Hz power supply

 

4  - Blue

 

5  - Brown

 

6  - Yellow/Green

 

7  - Black

 

8  - (DHW)

 

9  - (central heating)

  10  - Grey

  11  - White

  12  - Red

  13  - Green

  14  - Storage tank unit (optional)

Содержание 3.020857

Страница 1: ...MINI NIKE X 24 3 E Instruction booklet and warning IE 1 038792ENG...

Страница 2: ......

Страница 3: ...ions specified in the current regulation and technical standards In compliance with legislation in force the systems must be designed by qualified professionals within the dimensional limits establish...

Страница 4: ...ting 11 2 7 Boiler shutdown 13 2 8 Restore central heating system pressure 13 2 9 System draining 13 2 10 Anti freeze protection 13 2 11 Case cleaning 13 2 12 Decommissioning 13 3 Boiler start up init...

Страница 5: ...e intervenes with an obstructed conveying system the safety valve must be conveyed away by a draining funnel or if there are leaks from the hydraulic connections on the contrary the manufacturer canno...

Страница 6: ...order to meet the system requirements es tablished by the technical regulation in force in relation to the pollution of drinking water we recommend installing the IMMERGAS anti backflow kit to be used...

Страница 7: ...directly to the outside as long as the standard regulations for the flue terminal are respected as well as the existing laws Connection to chimneys or flues The connec tion of the appliances to a chim...

Страница 8: ...started up even if only one of the checks should be negative 1 14 CIRCULATION PUMP The Mini Nike X 24 3 E series boilers are supplied with a built in circulation pump with 3 posi tion electric speed c...

Страница 9: ...ystem filling valve 6 Flue safety thermostat 7 Flow probe 8 Primary heat exchanger 9 Safety thermostat 10 Combustion chamber 11 Ignition and detection electrodes 12 System expansion vessel 13 Burner 1...

Страница 10: ...is also prohibited in the same room as suction devices or the like at the same time as the boiler unless there are additional openings dimensioned in a way to satisfy the additional requirement for a...

Страница 11: ...The flow temperature can be modified by selecting the functioning curve via buttons 5 and 6 selecting a value from 0 to 9 Fig 1 5 With external probe present the relative symbol will appear on the dis...

Страница 12: ...ithout having to be reset 1 20 Parasite flame This occurs in the event of a leak in the detection circuit or an anomaly in the flame control unit Press the Reset button 1 24 Push button control panel...

Страница 13: ...3 bar the safety valve may be activated In this case remove water from an air vent valve of a radiator until 1 bar is reached or ask for as sistance from an authorised company In the event of frequen...

Страница 14: ...ce e g a draught gauge positioned at the exit of the appliance combustion products check that there is no backflow of combustion products into the room even during functio ning of fans ensure activati...

Страница 15: ...ficiency of gas intake circuit Irregular combustion red or yellow flame When the burner is dirty or the boiler lamellar pack is blocked Clean the burner or the boiler lamellar pack Frequent interventi...

Страница 16: ...boiler with storage tank 1 Lighting display Determining how to display illumination Display lighting P2 Range of values which can be set Standard setting 0 Off 1 Auto 2 On 1 Off the display is always...

Страница 17: ...sure to insert the special seal rings supplied in the kit between the gas manifold and the injectors apply voltage to the appliance use the boiler push button control panel to select the gas parameter...

Страница 18: ...tion phase the P C B supplies constant gas with pressure proportional to the parameter G2 set 3 10 CHIMNEY SWEEP FUNCTION When activated this function forces the boiler to variable output for 15 minut...

Страница 19: ...itate boiler maintenance the casing can be completely removed as follows Fig 3 4 3 5 1 Unhook the decorative frame a from the relative lower retainers 2 Remove the decorative frame a from the casing c...

Страница 20: ...20 3 5 4 4 5 6 6 d d c INSTALLATOR USER MAINTENANCE TECHNICIAN...

Страница 21: ...tion time must be less than 10 seconds Visually check for water leaks or oxidation from on connections Visually check that the water safety drain valve is not blocked Check that after discharging syst...

Страница 22: ...760 1 89 6 42 65 5 1 41 13 43 137 0 1 38 17 27 176 1 15 0 12900 1 77 5 70 58 1 1 32 12 00 122 4 1 30 15 43 157 3 14 0 12040 1 66 5 02 51 2 1 24 10 65 108 6 1 22 13 68 139 5 13 0 11180 1 55 4 39 44 8 1...

Страница 23: ...1 20 Heat loss at flue with burner On Off 6 70 0 09 Central heating circuit max operating pressure bar 3 Central heating circuit max operating temperature C 90 Adjustable central heating temperature C...

Страница 24: ...er CHK Check Cod PIN PIN code Type Type of installation ref CEN TR 1749 Qnw min Minimum heating capacity domestic Qn min Minimum heating capacity heating Qnw max Maximum heating capacity domestic Qn m...

Страница 25: ...25...

Страница 26: ...26...

Страница 27: ...27...

Страница 28: ...Europe S r o 059051 Poprad Matejovce SK Tel 421 524314311 Fax 421 524314316 IMMERGAS SPA ITALY CERTIFIED COMPANY UNI EN ISO 9001 2015 Design manufacture and post sale assistance of gas boilers gas wat...

Отзывы: