background image

24

4. START-UP INSTRUCTIONS 

QUESTIONS PRIOR TO START-UP 

• 

Before starting up the pump, carry out the following operations:

1.  Open the pre-filter cover (See Fig.5).
2.  Fill the pump with water through the pre-filter until it dips into the suction 

tube.

3.  If, during these operations the basket should have been taken out, do not 

forget to replace it inside the pre-filter so as to prevent large particles from 
entering the inside of the pump and thus blocking it

4.  Check that voltage and network power corresponds to those indicated on 

the pump specification board.

• 

Put the cover on the pre-filter and close it, without forgetting to place the joint in its 
housing. (Fig.5)

• 

Under  no  circumstances  should  pumps  work  without  previously  having  filled  the 
pre-filter with water. If this is not done, the mechanical joint could be damaged thus 
producing water loss through this.

• 

Check that the pump axle turns freely. 

Содержание NEW MP-025-M

Страница 1: ... Ê 1 Ê Ê Ê 1 Ê Ê 7 Ê 1 Ê 1 Ê 1 Ê 1 Ê 4 Ê 7 NEWMINIPUMP MANUAL DE INSTALACIÓN Y MANTENIMIENTO INSTALLATION AND MAINTENANCE MANUAL MANUEL DʼINSTALLATION ET DʼENTRETIEN HINWEISE FÜR EINBAU UND WARTUNG ...

Страница 2: ...pecific indications for each step The regulations in force for the prevention of accidents should be heeded Any modification that may be made to the pump requires the previous authorisation of the manufacturer The original manufacturer authorised spares and accessories guarantee greater safety The pump manufacturer is exempt from all responsibility for damage caused by the use of unauthorised spar...

Страница 3: ...ipe should be as short as possible in order to reduce the suction time The place where the pump is installed should be dry and aired at all times Special attention should be paid to ensure that under no circumstances water gets into the motor and the electric voltage parts Should the envisaged use not be different from that mentioned adaptations and supplementary technical regulations may be neces...

Страница 4: ...ake In case of irregularity stop the machine immediately and proceed with its repair Because of the complexity of cases dealt with the installation use and maintenance instructions in this manual do not intend to examine and deal with all possible service and maintenance situations If supplementary instructions are necessary or if specific problems arise do not hesitate to contact the machine dist...

Страница 5: ...installation is done totally perpendicularly and is well centred with respect to the nozzle to be connected so as to avoid external pressure being exerted on the pump and the tube Apart from making assembly more difficult this pressure could even break them Fig 2 Suction tube installation is done at a slight angle of 2 towards the pump thus avoided siphon formation Fig 2 For the pumpʼs good workin...

Страница 6: ...hat the suction tube is as short as possible since a long tube increases suction time and facility load loss It should be ensured that the pump is free from possible flooding and it is given dry ventilation SAFETY INDICATIONS ALL THE ELECTRICAL INSTALLATIONS MUST COMPLY WITH STANDARD EN 60335 2 41 All 230 v electrical units must be installed at a minimum distance of 3 5 meters from the edge of the...

Страница 7: ...als A heat protector is incorporated into single phase pumps In these switch installation is sufficient as in the Network connection diagram A protection differential of 0 03 A is needed for any pump in order to protect from electrical escapes shown in diagrams The heat relay regulation data for the single phase motor are merely illustrative since the motor comes with an incorporated protector CON...

Страница 8: ...t arrangement and connection of the earth wire in the equipment installation It is very important to keep to the installation and electrical connection conditions Should they not be heeded the pump manufacturer does not accept any responsibility and considers the guarantee void The motors are subject to EEC regulations with IP 55 protection Special installation regulations may exist Incorrect main...

Страница 9: ...the pre filter so as to prevent large particles from entering the inside of the pump and thus blocking it 4 Check that voltage and network power corresponds to those indicated on the pump specification board Put the cover on the pre filter and close it without forgetting to place the joint in its housing Fig 5 Under no circumstances should pumps work without previously having filled the pre filter...

Страница 10: ...nearest Customer Technical Service If the amp rate is higher consult the manufacturer Empty the pump in cases where it must remain without use for some time mainly in cold countries where there may be danger of freezing To empty the pump remove the draining plug from the pump body see explosion drawing Each time the pre filter is opened clean impurities from the joint seating and the joint itself ...

Страница 11: ... with the motor pump unit have been protected by IP 55 and are prepared to withstand hot atmospheres and high humidity levels The motors are also provided with a heat protector that avoids damage to the pump due to excess current 7 2 ELEMENTS SUPPLIED Self suction pump for water circulation in private swimming pools Pre filter incorporated in the pump body Pre filter basket Handle for pre filter b...

Страница 12: ...27 8 REGULATION Tests carried out on the New Minipump pump series have been done in accordance with the regulation EN ISO 9906 1999 ...

Страница 13: ...28 ...

Страница 14: ...G NUT M8 HD031070 13 IMPELLER NEWMP 025 HD051105 13 IMPELLER NEWMP 033 HD051110 13 IMPELLER NEWMP 050 HD051115 13 IMPELLER NEWMP 075 HD051125 14 PUMP BODY JOINT Ø143x4 HD021075 15 MECHANICAL SEAL Ø13 HD056000 16 PUMP BODY LID HD061025 17 PUMP BASE HD066000 18 SILENT BLOCK 9x45x13 HD071000 19 V RING JOINT VA 14 2 PCS MT001000 20 MOTOR FLANGE MT006010 21 ALLEN SCREW M6x25 4 PCS HD026010 22 BALL BEAR...

Страница 15: ...ACITOR 12 µF MT091000 31 SPRING WASHER M35 MT096000 32 MOTOR COVER MT016010 33 ROD M5x130 3 PCS MT101000 34 MOTOR FAN MT086040 35 MOTOR FAN RING MT086050 36 MOTOR FAN COVER MT086055 37 FAN COVER SCREW 3 PCS MT076035 38 ADAPTOR SOCKET NUT Ø50 2 PCS HD076010 39 SOCKET OʼRING Ø53x3 2 PCS HD021115 40 ADAPTOR SOCKET Ø50 2 PCS HD076005 41 PREFILTRE COVER HANDLE HD076000 42 COMPLETE MOTOR 0 33 HP 1 PH MT...

Отзывы: