background image

 

 

 

The information contained in this document supersedes all similar information that 
may be found elsewhere in this manual. 

  

 

 

Service 

–  Due  to  the  sophisticated 

nature  of  the  sensors  and  associated 
instrumentation 

provided 

by 

PCB 

Piezotronics,  user  servicing  or  repair  is 
not  recommended  and,  if  attempted, 
may  void  the  factory  warranty.  Routine 
maintenance,  such  as  the  cleaning  of 
electrical  connectors,  housings,  and 
mounting  surfaces  with  solutions  and 
techniques  that  will  not  harm  the 
physical  material  of  construction,  is 
acceptable. Caution should be observed 
to  ensure  that  liquids  are  not  permitted 
to  migrate  into  devices  that  are  not 
hermetically 

sealed. 

Such 

devices 

should  only  be  wiped  with  a  dampened 
cloth  and  never  submerged  or  have 
liquids poured upon them.   
 

Repair 

–  In  the  event  that  equipment 

becomes 

damaged 

or 

ceases 

to 

operate,  arrangements  should  be  made 
to  return  the  equipment  to  PCB 
Piezotronics for repair. User servicing or 
repair  is  not  recommended  and,  if 
attempted, 

may 

void 

the 

factory 

warranty.     
 

Calibration 

–  Routine  calibration  of 

sensors  and  associated  instrumentation 
is  recommended  as  this  helps  build 
confidence  in  measurement  accuracy 
and 

acquired 

data. 

Equipment 

calibration 

cycles 

are 

typically 

established  by  the  users  own  quality 
regimen.  When  in  doubt  about  a 
calibration cycle, a good 

“rule of thumb” 

is to recalibrate on an annual basis. It is 

also  good  practice  to  recalibrate  after 
exposure  to  any  severe  temperature 
extreme, 

shock, 

load, 

or 

other 

environmental  influence,  or  prior  to  any 
critical test.  
 
PCB  Piezotronics  maintains  an  ISO- 
9001  certified  metrology  laboratory  and 
offers  calibration  services,  which  are 
accredited  by  A2LA  to  ISO/IEC  17025, 
with  full  traceability  to  SI  through 
N.I.S.T.  In  addition  to  the  normally 
supplied  calibration,  special  testing  is 
also  available,  such  as:  sensitivity  at 
elevated  or  cryogenic  temperatures, 
phase  response,  extended  high  or  low 
frequency  response,  extended  range, 
leak 

testing, 

hydrostatic 

pressure 

testing,  and  others.  For  information  on 
standard 

recalibration 

services 

or 

special  testing,  contact  your  local  PCB 
Piezotronics 

distributor, 

sales 

representative,  or  factory  customer 
service representative.   
 

Returning  Equipment 

– 

Following 

these  procedures  will  ensure  that  your 
returned  materials  are  handled  in  the 
most 

expedient 

manner

Before 

returning 

any 

equipment 

to 

PCB 

Piezotronics, 

contact 

your 

local 

distributor,  sales  representative,  or 
factory  customer  service  representative 
to  obtain  a  Return 

Warranty,  Service, 

Repair,  and  Return  Policies  and 
Instructions 

Materials  Authorization 

(RMA)  Number.  This  RMA  number 
should be clearly marked on the outside 
of  all  package(s)  and  on  the  packing 

Service, Repair, and Return 
Policies and Instructions 

Содержание Y685B0001A13

Страница 1: ...on Switch Installation and Operating Manual For assistance with the operation of this product contact PCB Piezotronics Inc Toll free 800 959 4464 24 hour SensorLine 716 684 0001 Fax 716 684 3823 E mai...

Страница 2: ...ty regimen When in doubt about a calibration cycle a good rule of thumb is to recalibrate on an annual basis It is also good practice to recalibrate after exposure to any severe temperature extreme sh...

Страница 3: ...rchase Order should include authorization to proceed and return at current pricing which can be obtained from a factory customer service representative Contact Information International customers shou...

Страница 4: ...isclosure Table Pb Hg Cd Cr VI PBB PBDE O O O O O O PCB X O O O O O O O O O O O X O O O O O O O O O O O O O O O O O O O O O O O O O X O O O O O O O O O X O O O O O O O O O O O X O O O O O X O O O O O...

Страница 5: ...e O O X O O O Wires O O O O O O Cables X O O O O O Plastic O O O O O O Solder X O O O O O Copper Alloy Brass X O O O O O This table is prepared in accordance with the provisions of SJ T 11364 O Indica...

Страница 6: ...NITORING Series 685B Electronic Vibration Switch Operating Guide with Enclosed Warranty Information 3425 Walden Avenue Depew New York 14043 2495 Phone 716 684 0003 Fax 716 684 3823 Toll Free Line 1 80...

Страница 7: ...gs Connector Pinout Diagram Triac Models Connector Pinout Diagram Relay Models Configuring the 685B Page 11 Internal Diagram Triac Models Internal Diagram Relay Models Using Calibration Mode Connectin...

Страница 8: ...and frequency response Vibration range can be measured in Acceleration Velocity or Displacement factory set Provides Dual 5 Amp Triac SPST or 10 Amp Form C SPDT relay outputs Adjustable trip limits a...

Страница 9: ...Relay SPDT Operating Temperature Range 22 to 158 F 30 to 70 C Storage Temperature Range 40 to 257 F 40 to 125 C Relative Humidity Nema 4X Rating Case Dimension W x H x D 3 5 x 2 8 x 3 5in 90 x 70 x 9...

Страница 10: ...o options to retrofit existing 3 bolt pattern installations Model 080A209 mounting plate required see optional accessories on page 13 Use grease between all surfaces to insure specified frequency resp...

Страница 11: ...PAGE 6 SENSORS AND INSTRUMENTATION FOR MACHINE CONDITION MONITORING Standard Model Dimension Drawing with NPT Conduit Hubs Inch mm...

Страница 12: ...ORING Explosion Proof Model Dimension Drawing Inch mm WARNING AC and DC input signals and power supply voltages could be hazardous DO NOT connect live wires to screw terminal plugs and DO NOT insert r...

Страница 13: ...tion Diagram Triac Models Pin Descriptions AC Power Pins 1 to 3 1 Power 2 Power Common 3 Earth Ground also connect earth ground to safety lug inside enclosure Alarm Output Pins 4 and 5 4 Main Terminal...

Страница 14: ...y Open when energized 5 Common connection 6 Normally Open de energized contact Normally Closed when energized Alert Output Pins 7 to 9 7 Normally Closed de energized contact Normally Open when energiz...

Страница 15: ...l 100mV g ICP Sensor option is specified an additional terminal block location is added to the 685B series The external accelerometer is connected to Sensor and Senor positions as indicated in the abo...

Страница 16: ...ay is set using the third The alert relay trips when the set percentage of the alarm value is reached Time delays for both functions are controlled using the second and fourth potentiometers Alert and...

Страница 17: ...trips when the set percentage of the alarm value is reached Time delays for both functions are controlled using the second and fourth potentiometers Alert and alarm relays can be reset remotely using...

Страница 18: ...larm signal based on the calculation in the previous step for the alarm signal 6 Adjust the SP Alarm set point potentiometer to the point when the red Alarm LED illuminates 7 Using the 4 20 mA simulat...

Страница 19: ...NG the digital analyzer input Connect the analyzer to Pins 10 11 with the common connection on the pin Pin 10 and the signal connection on the RV Output pin Pin 11 Optional Accessories Model 080A209 A...

Страница 20: ...MACHINE CONDITION MONITORING Model 699A05 Portable 4 20 mA Calibrator Provides current output for Series 685B testing read out and calibration purposes Also receives and displays current signal from 4...

Страница 21: ...ischarge ESD can damage electrical devices Similar to a capacitor a cable can hold a charge caused by triboelectric transfer such as that which occurs in the following Laying on and moving across a ru...

Страница 22: ...er Required 0 85 245 VAC 50 60 Hz 1 24 VDC 10 Relay Type two provided 0 Triac 5A 245vac 1 Form C Relay SPDT 10A 245Vac 5A 30Vdc Enclosure Type Hazardous Area Approval A1 Basic enclosure internal pushb...