1.2 System C
onfiguration MENU
In this MENU basic functions are provided. Activation by pressing the arrow buttons
▼
+
▲
simultaneously during the
power-on procedure.
The following functions are provided:
33d INFO:
Information of the software version und Serial number.
Set LIGHT:
Switch-ON or OFF of the permanent illumination. The OFF-status however still provides illumination of
the display during the course of any operation and ceases to light automatically after 10 seconds of
inactivity.
Set ZERO:
The pressure indication in the zero point can be suppressed in % FS, i.e. 1% FS of 100 ( = 1 bar)
means, that the pressure indication up to 1 bar is actually indicated as 0 bar. Flickering digits on the
display (in the zero point) can be avoided.
no CODE:
This function allows the code elimination with the help of the master code combination (page 10).
The „set code“ function can either be deleted or activated.
End MENU:
Storing and back to Operating Display (indication of system pressure)
2. Setting of the Switching points
Press SET once for the switching point of OUT 1 (OUT 2) and choose your set value by using the arrow buttons. Press
SET for confirmation and continue with the reset point of OUT 1 (OUT 2). In case of inactivity for more than 12
seconds the display returns to the operating display without storing the set values. By pressing both arrow buttons
simultaneously this function can be terminated immediately and the display returns to the operating display wihout
storing the settings.
2.1. Standard-MODE:
Depending on the chosen polarity (n.c / n.o, see setup) the corresponding switching diagram appears on the display
and the presently adjustable switching flank blinks. The switching point is marked by the arrow pointing upwards
(Switching OUT activated = rising flank)
Accordingly the reset point is marked by the arrow pointing downwards (Switching OUT inactivated = falling flank)
Pressing the SET button stores the setting and makes the display to switch to the next step.
Picture 1: Switching OUT 1 in the standard mode with (n.o.), switching OUT 2 in the standard mode (n.c.)
8
EN
7503442.99.10.01
Subject to change without notice