TM
1
ǃ
Open cistern panel system
2
ǃ
Replace fill valve
Push the bottom of cistern panel upwards,
turn the top of cistern panel about 30,take
the panel out of the panel frame.
Remove the screw,take
out of the panel frame.
To remove panel board,turn it
over about 30 from the top,
take it out aslant &upwards.
Close the stop valve, loosen
and remove the flexible
connection pipe.
Maintenance Manual of Concealed Cistern
(Suit for standing floor toilet)
Take out the fill valve aslant.
Remove the screws and
take off the panel board
Pull out the valve from the coupling.
Pull up the fill valve at an angel.
3
ǃ
Replace flush valve
Pull the flush valve with left hand
lightly,with the right hand holding the
flush frame top and pull it out.
Move the flush frame to the
right and take it out.
Turna the flush upside down
Pull the flush valve
upwards slightly
Take out the flush valve
at an angel
Technologic data:
.1
2 standard
fill w
a
ter hole.
.The water stress range of fill water it 0.02~1.0Mpa.
.The water temperature range is 2 ~45 .
.3L
6L dual flush water volume,the flush water time is 3s~5s.
.The product can be installed in the wall of 78mm thickness.
CC100
F
Super slim concealed insulated cistern with chrome front
mounted dual flush plate
0.2 - 4 bar