background image

 

Display illuminations 

 

Pressing this button for longer switches the illuminations on or off.   

 

Selecting Units 

 

 

Press this key until the desired unit is displayed. 

 

Optional units: 

Length 

Area 

Volume 

0.000 m   

0.000 m²   

0.000 m³   

0.00m 

0.00 m² 

0.00 m³ 

0.00 ft 

0.00 ft² 

0.00 ft³ 

0.00

1/16 

ftin 

0.00 ft² 

0.00 ft² 

0' 0'' 

1/16

 

0.00 ft² 

0.00 ft³ 

0.0 in 

0.00 ft² 

0.00 ft² 

1/16

 in 

0.00 ft² 

0.00 ft³ 

 

M

M

M

e

e

e

a

a

a

s

s

s

u

u

u

r

r

r

i

i

i

n

n

n

g

g

g

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Single distance measurement 

  Press to activate the laser.   

  Press again to trigger the distance measurement. The result is displayed 

immediately. 

Содержание Bullseye 80

Страница 1: ...USER MANUAL V1 0 ...

Страница 2: ...1 ...

Страница 3: ...2 2 4 1 3 6 5 8 7 9 Secondary line 2 Secondary line 1 Summary line ...

Страница 4: ...ch if not avoided may result in minor injury and or in appreciable material financial and environmental damage Important paragraphs which must be adhered to in practice as they enable the product to be used in a technically correct and efficient manner Use of the instrument Permitted use Measuring distances Computing functions e g areas and volumes Storing measurements Prohibited use Using the ins...

Страница 5: ...essive environments Areas of responsibility Responsibilities of the manufacturer of the original equipment original manufacturer is responsible for supplying the product including the User Manual and original accessories in a completely safe condition Responsibilities of the person in charge of the instrument WARNING The person responsible for the instrument must ensure that equipment is used in a...

Страница 6: ...s measurements Precautions Only use this product as a measuring sensor not as a control device Your system must be configured and operated in such a way that in case of an erroneous measurement malfunction of the device or power failure due to installed safety measures e g safety limit switch it is assured that no damage will occur WARNING Dispose of the product appropriately in accordance with th...

Страница 7: ...rcraft It can also affect humans and animals Precautions Although this product conforms to the most stringent standards and regulations Imex cannot totally exclude the possibility of harm to people and animals Do not use the product near petrol stations chemical plants in areas with a potentially explosive atmosphere and where blasting takes place Do not use the product near medical equipment Do n...

Страница 8: ... r rt t t u u up p p Inserting Replacing Batteries 1 Remove the battery compartment lid 2 Insert the batteries Pay attention to correct polarity 3 Close the battery compartment When the battery voltage is too low the batteries should be replaced as soon as possible Batteries should be removed if the device will not be used for a long time danger of corrosion Use alkaline batteries End piece The in...

Страница 9: ...r longer switches the instrument off The instrument switches off automatically after 3 minutes of inactivity Clear button The last action is cancelled While making area or volume measurements each single measurement can be deleted and remeasured in series Refernce setting The default reference setting is from the rear of the instrument Press this button to set the reference the front or the rear T...

Страница 10: ...Length Area Volume 0 000 m 0 000 m 0 000 m 0 00m 0 00 m 0 00 m 0 00 ft 0 00 ft 0 00 ft 0 001 16 ftin 0 00 ft 0 00 ft 0 0 1 16 0 00 ft 0 00 ft 0 0 in 0 00 ft 0 00 ft 0 1 16 in 0 00 ft 0 00 ft M M Me e ea a as s su u ur r ri i in n ng g g Single distance measurement Press to activate the laser Press again to trigger the distance measurement The result is displayed immediately ...

Страница 11: ...re shown on the display as well as the last measured value in the summary line F F Fu u un n nc c ct t ti i io o on n ns s s Arithmetic The previous measurement result adds to the next one The previous measurement result subtracts to the next one Press this button and the result will be shown in the summary line The last step will be cancelled The parameters that participate in the calculating mus...

Страница 12: ... held without a transverse tilt max 10 Staking out function A distance can be set and then be used to mark off defined measured lengths Input staking out distances Press this button until this symbol appears on the display Distance flashes on the display By using and button you can adjust the values to suit the desired stacking out distance Press key to confirm it Press this key to take the stack ...

Страница 13: ...ents at right angles to the target the maximum distance for all other measurements Pythagorean calculation It is helpful to use a tripod when measuring heights that require the measurement of two or three measurements Single Pythagorean calculation E g measure the height or width of a building Press this button until this symbol appears on the display Aim at the upper point and trigger the measure...

Страница 14: ...d down over the ideal target point Press to stop the measurement then the minimum value is adopted Press this button to trigger the measurement Then the third value is adopted The result is displayed in the summary line the partial results in the secondary lines Storage of constant historical storage Storage of constant You can store and recall a frequently used value e g height of a room Measure ...

Страница 15: ...ased with the laser activated the remaining seconds until measurement e g 59 58 57 are displayed in a countdown The last 5 seconds are counted down with a beep After the last beep the measurement is taken and the value is displayed Tilt sensor calibration You can calibrate the tilt sensor in the device Calibration requires two measurements on a level surface Carry out 1st measurement on a level su...

Страница 16: ... Receiver signal too weak Use target plate 256 Received signal too strong Use target plate grey side 205 Ranging transfinite Use in allowed ranging 206 Wrong parameter When measuring by Pythagoras the length of hypotenuse should be greater than the other two lengths The parameter calculated must have the same unit 156 Transverse tilt greater than 10 Hold the instrument without any transverse tilt ...

Страница 17: ...function Historical storage 99 Measure range of tilt sensor 360 Accuracy of tilt sensor 0 3 Battery life Type AAA 2 1 5V up to 5000 measurements Dimension 122 46 25 mm Weight 105g Temperature range Storage Operating 25 to 70 10 to 50 Maximum deviation occurs under unfavorable conditions such as bright sunlight or when measuring to poor reflecting or very rough surfaces For distances over 80m witho...

Страница 18: ... can occur Against non reflective and dark surfaces the measuring time can be increased Care Do not immerse the unit in water Wipe off dirt with a damp soft cloth Do not use aggressive cleaning agents or solutions Treat the optical surfaces with the same care that you would apply to eyeglasses and cameras W W Wa a ar r rr r ra a an n nt t ty y y Warranty Regulations 1 A two year warranty is availa...

Страница 19: ...d Held Laser Distance Meter Model Bullseye 80 Testing Date Instrument Model Serial Number Date of sales Sale company Sale Address NO Name Quantity Unit Remarks 1 Main body 1 pc 2 AAA battery 2 pcs 2 Instrument cap 1 pc 4 Lanyard 1 pc 5 User manual 1 pc ...

Страница 20: ...19 Copyright Imex Group International 2016 www imexlaseres com ...

Отзывы: