9. TRANSPORTATION
- Before removing the panel saw, lock the carriage using the
ting the machine with a fork lift, insert the left fork in the slot provided
surfaces as follows:
1. make sure that the front wheel brakes are released.
2. make sure that the piece holder carriage is clamped with the special
3. pull the machine by hand using the piece holder carriage grip; move-
ment (also round corners) is facilitated by the front castor wheels.
10. INSTALLATION
1. Install the machine on a completely even and stable surface.
2. Block the front wheels with the brakes.
3. Release the carriage from the lever that secures it to the frame (ref.4,
11. ELECTRICAL MAINS CONNECTION
- Make certain that a residual current device and miniature
circuit breaker are installed on the electrical power line.
11.1 Connecting versions with motor 115V/60Hz
Ensure that the supply voltage corresponds to machine dataplate speci-
- To supply the machine it is necessary to use a 2-pole +
ground cable in order to ensure the machine's connection to the
site's equipotential system.
11.2 Connecting versions with motor 220V/60Hz
Ensure that the supply voltage corresponds to machine dataplate speci-
- To supply the machine it is necessary to use a 3-pole +
ground cable in order to ensure the machine's connection to the
site's equipotential system.
11.3 Sizing the power supply cable
The power supply line must be suitably sized to prevent voltage drops.
Do not use cable winders. The electric cable wire size must take into
account the operating currents and length of the line to avoid excessive
voltage drops (table 4).
Table 4
Model
Type of motor
1.5
2.5
4.0
Masonry 700
Single-phase
Masonry 700
Three-phase
220 V
23.2 A
0 - 12
13 - 24
25 - 50
220 V
22 A
0 - 12
13 - 24
25 - 50
sheathing that is resistant to wear, crushing and extreme weather condi-
tions (for example H07RN-F).
- All power supply installations must comply with CEI 64-8
standards (harmonised document CENELEC HD384).
12. MACHINE START-UP
Before connecting the machine to the power supply:
1. Ensure that the metal structure is connected to an earthing plant as
90 L).
3. Ensure that the power circuit corresponds to the requirements as in-
4. Connect the machine to the power supply
5. Turn the start-stop selector to the start position (star connection). Wait
for 5 sec. and turn to the running position (delta connection).
6. Check that the direction of blade rotation corresponds to that indica-
ted by the arrow on the blade guard.
the direction of rotation of the disk is the opposite of the arrow on
the protective guard, disconnect the power socket from the plug
on the machine and invert a phase. To do this, exchange the two
mobile terminals on the poles using a screwdriver. This operation
is carried out without removing the plug working on the rotary ele-
ment that holds the mobile poles.
guard (do not perform cutting without water).
8. If all is in order, proceed with cutting.
13. EMERGENCY STOP
- In the case of an emergency, stop the machine pressing the
special red mushroom button. To start again, reset the mushroom
button turning it clockwise and turn the selector to zero, then re-
14. BLADE INSTALLATION
2.Release the spring catches clamping the disk mobile guard (ref. 3,
thread).
- Never use worn blades or blades with missing segments.
- Only use blades that are designed for the number of revolu-
tions indicated on the machine rating plate.
- Check that the direction of rotation of the disk is as shown
on the disk guard.
counter-clockwise (left-hand thread).
7. Put the water pipe back in place and tighten the fastener until the pipe
Fig. 6
- Ensure that the blade guard (ref.3) is locked securely into
position.
tightened can provoke damage to the machine
or injury to persons.
- Note that the blade must have an external
diameter of 700 mm, a central hole diameter of
25.4 mm and max. thickness of 4 mm.
- Check that the blade to be used is suitable
for the material to be cut.
15. USE
- Leave a space of 150 cm around the machine to operate in
full safety.
explosions.
dling.
- Ensure correct installation of all protective devices.
never necessary: N.B. the pump suction hose must always remain im-
mersed in water.
- For safety purposes the removal of protective guards from
the machine is strictly prohibited.
- The machine is protected against overload: this protection
triggers stopping the machine, after which the time necessary for
the overload to cool must pass before it is possible to restart the
machine.
- To resume work after a voltage cut-off, turn the selector to