9. TRANSPORTATION

 

- Before removing the panel saw, lock the carriage using the 

ting the machine with a fork lift, insert the left fork in the slot provided 

surfaces as follows:
1. make sure that the front wheel brakes are released.
2. make sure that the piece holder carriage is clamped with the special 

3. pull the machine by hand using the piece holder carriage grip; move-
ment (also round corners) is facilitated by the front castor wheels.

10. INSTALLATION
1. Install the machine on a completely even and stable surface.
2. Block the front wheels with the brakes.
3. Release the carriage from the lever that secures it to the frame (ref.4, 

11. ELECTRICAL MAINS CONNECTION

 

-  Make  certain  that  a  residual  current  device  and  miniature 

circuit breaker are installed on the electrical power line.

11.1 Connecting versions with motor 115V/60Hz
Ensure that the supply voltage corresponds to machine dataplate speci-

 

-  To  supply  the  machine  it  is  necessary  to  use  a  2-pole  + 

ground cable in order to ensure the machine's connection to the 
site's equipotential system.

11.2 Connecting versions with motor 220V/60Hz
Ensure that the supply voltage corresponds to machine dataplate speci-

 

-  To  supply  the  machine  it  is  necessary  to  use  a  3-pole  + 

ground cable in order to ensure the machine's connection to the 
site's equipotential system.

11.3 Sizing the power supply cable
The power supply line must be suitably sized to prevent voltage drops.
Do not use cable winders. The electric cable  wire size must take into 
account the operating currents and length of the line to avoid excessive 
voltage drops (table 4).

Table 4

Model

Type of motor

1.5

2.5

4.0

Masonry 700 
Single-phase
Masonry 700 

Three-phase

220 V

23.2 A

0 - 12

13 - 24

25 - 50

220 V

22 A

0 - 12

13 - 24

25 - 50

sheathing that is resistant to wear, crushing and extreme weather condi-
tions (for example H07RN-F).

 

-  All  power  supply  installations  must  comply  with  CEI  64-8 

standards (harmonised document CENELEC HD384).

12. MACHINE START-UP
Before connecting the machine to the power supply:
1. Ensure that the metal structure is connected to an earthing plant as 

90 L).
3. Ensure that the power circuit corresponds to the requirements as in-

4. Connect the machine to the power supply
5. Turn the start-stop selector to the start position (star connection). Wait 
for 5 sec. and turn to the running position (delta connection).
6. Check that the direction of blade rotation corresponds to that indica-
ted by the arrow on the blade guard.

the direction of rotation of the disk is the opposite of the arrow on 

the protective guard,  disconnect the power socket from the plug 
on the machine and invert a phase. To do this, exchange the two 
mobile terminals on the poles using a screwdriver. This operation 
is carried out without removing the plug working on the rotary ele-
ment that holds the mobile poles.

guard (do not perform cutting without water).
8. If all is in order, proceed with cutting.

13. EMERGENCY STOP

 

- In the case of an emergency, stop the machine pressing the 

special red mushroom button. To start again, reset the mushroom 
button turning it clockwise and turn the selector to zero, then re-

14. BLADE INSTALLATION

2.Release  the  spring  catches  clamping  the  disk  mobile  guard  (ref.  3, 

thread).

 - Never use worn blades or blades with missing segments.

 - Only use blades that are designed for the number of revolu-

tions indicated on the machine rating plate.

 

- Check that the direction of rotation of the disk is as shown 

on the disk guard.

counter-clockwise (left-hand thread).

7. Put the water pipe back in place and tighten the fastener until the pipe 

Fig. 6

 

-  Ensure  that  the  blade  guard  (ref.3)  is  locked  securely  into 

position.

tightened  can  provoke  damage  to  the  machine 
or injury to persons.

 - Note that the blade must have an external 

diameter of 700 mm, a central hole diameter of 
25.4 mm and max. thickness of 4 mm.

 - Check that the blade to be used is suitable 

for the material to be cut.

15. USE

 

- Leave a space of 150 cm around the machine to operate in 

full safety.

explosions.

dling.

 - Ensure correct installation of all protective devices.

never necessary: N.B. the pump suction hose must always remain im-
mersed in water.

 

- For safety purposes the removal of protective guards from 

the machine is strictly prohibited.

 

- The machine is protected against overload: this protection 

triggers stopping the machine, after which the time necessary for 
the overload to cool must pass before it is possible to restart the 
machine.

 

- To resume work after a voltage cut-off, turn the selector to 

Содержание MASONRY 700

Страница 1: ...IMER WEST 3654 Enterprise Avenue Hayward CA 94545 Ph 510 670 7970 Fax 510 783 4255 IMER EAST 221 Westhampton Place Capitol Heights MD 20743 Ph 301 336 3700 Fax 301 336 6687 IMER U S A Inc Toll Free 80...

Страница 2: ...Guide bar 4 Carriage 5 Trolley clamping 6 Workpiece 7 Spray guard 8 Motor 9 Junction box 10 Plug 11 Cutting head group 12 Blade 13 Disc cover 14 Blade cover 15 Drum 16 Water pump 17 Adjusting cut leve...

Страница 3: ...th x height 850x1550x1600 mm Overall dimensions for transport width x length x height 850x1550x1600 mm Sawing machine operating weight 285 Kg Weight for transport 202 Kg Table 2 Feature Motor 220V 60H...

Страница 4: ...responds to the requirements as in 4 Connect the machine to the power supply 5 Turn the start stop selector to the start position star connection Wait for 5 sec and turn to the running position delta...

Страница 5: ...lade must have an external diameter of 650 mm a central hole diameter of 25 4 mm and max thickness of 4 mm 17 MAINTENANCE cians and only after the motor has been switched off Always keep the guards in...

Страница 6: ...tions must be performed exclusively with the machine switched off with the selector set to Fault Cause Remedy Motor does not start when switch is turned Defective power cable Check power cables Plug n...

Страница 7: ...IMER U S A Inc MASONRY 700 7 FIG 2 FIG 4 FIG 5 FIG 7 FIG 8 FIG 9...

Страница 8: ...IMER U S A Inc MASONRY 700 8...

Страница 9: ...2RS1 55 3206079 KNOB 56 3206722 KEY 8X7X30 57 3206973 LEVER 58 3207152 BOLT TCB 7687 M5X20 59 3207393 SPACER BRACKET 60 3207397 WHEEL 61 3208455 BOLT TTDE M10X35 5732 Z 62 3208726 WATER PUMP 63 32104...

Страница 10: ...442 CABLE CLAMP 3 3201503 CABLE CLAMP 4 3226296 JUNCTION BOX 5 3228375 SAFETY CATCH BUTTON 6 3226298 SWITCH 7 3228376 CONTACTOR 8 3228374 MAGNETOTHERMAL MOTOR OVERLOAD PROTECTION CIRCUIT BREAKER 9 322...

Страница 11: ...201503 CABLE CLAMP 4 3230333 ELECTRIC BOARD 5 3207929 SUPPORT 6 3207928 START AND STOP SWITCH 7 3207924 THERMO MAGNETIC CUTOUT SWITCH 8 3207922 COIL RIF ID CUTOUT SWITCH 30 mA I1 THERMO MAGNETIC CUTOU...

Страница 12: ...IMER U S A Inc MASONRY 700 12...

Страница 13: ...nce unreasonable use faulty repairs or which has not been mantained and operated in accordance with our printed instructions for our equipment Further this warranty is void if the equipment or any of...