![iMege G2212E Скачать руководство пользователя страница 43](http://html1.mh-extra.com/html/imege/g2212e/g2212e_user-manual_2046171043.webp)
42
6. The front LED indicator will be slow flashing in red color during the upgrading process. When it
becomes steady on in green color, camera is ready to be accessed. Check the firmware version to
confirm that the system is successfully upgraded.
Recover device settings
In some cases, camera system does not respond to any operation. A certain recovering processes would help
to get the unit back to initial status, so that it can resume operable / configurable. This will be the operations
on the “Reset Button”.
1. Restart / Reboot the device
Short
Reset pin
and
Ground
pin
of the terminal block within 1 second; the system will be restarted.
2. Reset
User
Management
Short
Reset pin
and
Ground
pin
of the terminal block for 5~9 seconds; User management settings
will be reset to default and the system will be restarted.
3. Reset to factory default settings
Short
Reset pin
and
Ground
pin
of the terminal block for over 10 seconds; the system will be reset to
factory default and the system will be restarted.
Содержание G2212E
Страница 1: ...G2212E User s Manual V1 11a...
Страница 14: ...13 ePTZ Control Pannel Pan Tilt control buttons Zoom In Out control buttons Area of view...
Страница 40: ...39 Connectors I O connectors Pin definitions...
Страница 41: ...40 Schematic diagram of Digital I O C B E S S D D G G RX IN VCC12 Digi in 1 2 1 2 Digi out 3V3 DO OUT 1 2...