background image

EN – Oil Free Silent Air Compressor

 

046 ‐ LI ‐SP‐EN‐ GENERAL SILENCIOSOS REV 171121

 

13 / 24 

 

EN – INSTRUCTIONS BOOK 

 

INDEX: 

 

1.‐ INTRODUCTION 

14

 

2.‐ CAUTIONS 

15

 

3.‐ INTRODUCTION OF THE MACHINE 

15

 

4.‐ SAFETY INSTRUCTIONS. 

16

 

5.‐ OPERATION 

17

 

5.1.‐ Tank safety valve 

17

 

5.2.‐ Pressure switch 

17

 

5.3.‐ Air receiver 

17

 

5.4.‐ Oil 

17

 

6.‐ INSTALLATION AND LOCATION 

18

 

7.‐ OPERATING INSTRUCTIONS 

18

 

7.1.‐ First start, or after a long time of storage 

18

 

8.‐ MAINTENANCE 

19

 

8.1.‐ Daily or before each use 

19

 

8.2.‐ Weekly 

19

 

8.3.‐ Monthly 

19

 

9.‐ POSSIBLE FAULTS AND TROUBLE SHOOTING 

20

 

10.‐ TECHNICAL DATA 

21

 

11.‐ SPARE PARTS 

21

 

12.‐ WASTES AND ENVIRONMENT 

21

 

 

 

 

 

Do not reproduce any part of this manual instructions book, it is forbidden. 

 

 

 

Содержание 04606

Страница 1: ...REV 171121 www imcoinsa es La imagen puede variar seg n modelo Image may vary depending on the model LIBRO DE INSTRUCCIONES INSTRUCTIONS BOOK COMPRESOR SILENCIOSO SIN ACEITE OIL FREE SILENT AIR COMPRE...

Страница 2: ...Compresor Silencioso Sin Aceite Oil Free Silent Air Compressor 046 LI SP EN GENERAL SILENCIOSOS REV 171121 Pag 2 24 ES LIBRO DE INSTRUCCIONES 3 EN INSTRUCTIONS BOOK 13...

Страница 3: ...ito de aire 7 5 2 Presostato o Interruptor de presi n 7 5 3 Dep sito de aire 7 5 4 Aceite 7 6 INSTALACI N Y UBICACI N 8 7 INSTRUCCIONES PARA SU USO 8 7 1 Primera puesta en marcha o despu s de un largo...

Страница 4: ...estas normas por favor tenga en cuenta las distintas normativas de aplicaci n vigentes en aquellos lugares donde se utilice la m quina IMCOINSA se reserva el derecho de realizar modificaciones o mejo...

Страница 5: ...creto 286 06 sobre la protecci n de la salud y la seguridad de los trabajadores contra los riesgos relacionados a la exposici n al ruido y Directiva 2003 10 CE que recoge las medidas de protecci n de...

Страница 6: ...har mejor su trabajo y trabajar de una forma m s segura si se utiliza dentro del margen de funcionamiento valores nominales especificados Utilice siempre la herramienta el ctrica con caracter sticas t...

Страница 7: ...anillo de la v lvula de seguridad no est obstruido En caso necesario sustituir la v lvula 5 2 Presostato o Interruptor de presi n El presostato permite obtener un ptimo funcionamiento del compresor P...

Страница 8: ...arriba del bot n del presostato para el modelo 04607 accionar el bot n on off y esperar a que se vaya llenando el dep sito hasta que alcance por lo menos las 4 atms o la presi n m nima de trabajo de l...

Страница 9: ...na se mantenga durante mucho tiempo es obligatorio que el Distribuidor donde adquiri el producto o el Servicio T cnico IMCOINSA m s cercano la controle al menos una vez al a o Todos los d as antes de...

Страница 10: ...lvula de seguridad 1 Comprobar la regulaci n del presostato y sustituirlo si fuera necesario 2 Comprobar la v lvula manualmente tirando de los anillos Sustituirla si fuera necesario V lvula solenoide...

Страница 11: ...citar cualquier recambio es imprescindible facilitar el modelo y n mero de serie de la m quina Esta informaci n la encontrar en la placa de IMCOINSA que se encuentra en un sitio visible de la m quina...

Страница 12: ...ES Compresor Silencioso Sin Aceite 046 LI SP EN GENERAL SILENCIOSOS REV 171121 12 24 Notas...

Страница 13: ...lve 17 5 2 Pressure switch 17 5 3 Air receiver 17 5 4 Oil 17 6 INSTALLATION AND LOCATION 18 7 OPERATING INSTRUCTIONS 18 7 1 First start or after a long time of storage 18 8 MAINTENANCE 19 8 1 Daily or...

Страница 14: ...tart this machine in a correct way and to explain the safety procedures of the European Community in order to avoid any risks which could occur due to a misuse of the machine This machine must be used...

Страница 15: ...e properly assembled Start working with the machine only in case you fulfil both safety and instruction regulations The workers must know about all the safety regulations Level noise of this machine c...

Страница 16: ...tool will work better and will work in a safe way if it works under its operating values nominal specified values Use always the compressor with the technical characteristics according to the work wh...

Страница 17: ...eed 5 2 Pressure switch The air pressure switch is set at the factory to get the best performance from your equipment Do not ever bypass or remove this switch because this could cause serious damages...

Страница 18: ...06 04624 and 04650 to turn the compressor on pull the bottom of the pressure switch up for model 04607 push on off button and wait until the air fills the air receiver until the pressure of the tank i...

Страница 19: ...afety and the performance of the machine for a long time the Distributor where you purchased the machine or the nearest Technical Service of IMCOINSA should check it at least once a year Every day bef...

Страница 20: ...ure switch and replace in case the problem persists 2 Check valve manually by pulling upward on rings In case the problem persists replace defective valve Solenoid valve leaks when compressor is in st...

Страница 21: ...es To order any spare part you must provide us the model and serial number of the machine You will find this information at the technical plate of IMCOINSA which is placed in a visible place of the ma...

Страница 22: ...EN Oil Free Silent Air Compressor 046 LI SP EN GENERAL SILENCIOSOS REV 171121 22 24 Notes...

Страница 23: ...LENCE 07 PLUS 046062 COMPRESOR COMPRESSOR SILENCE 24 04624 COMPRESOR COMPRESSOR SILENCE 50 04650 Cumple todas las disposiciones aplicables de las siguientes Directivas Normas y Especificaciones T cnic...

Страница 24: ...Imcoinsa 1985 S L P I Astolabeitia 4C 1 Apdo 32 48220 Abadiano Vizcaya Telf 34 946 810 721 Fax 34 946 200 460 e mail comercial imcoinsa es www imcoinsa es...

Отзывы: