background image

IP700 

 

 
OPERATING : 

 

 

 

 

 

 

 

·

  Turn the key switch to select the ON position. 

·

  Select NORMAL or CONSTANT operation.  

 

 

If NORMAL is selected the unit will cycle once only: the ram will move to the down 
position, pause for four seconds and return to the fully up position where it will stop. 
 
CONSTANT leaves the ram in the down position until released by turning the switch from 
constant to normal. Use this mode for resilient material which has resistance to 
compaction. 

  

·

  Open the door and place waste material into the wheelie bin. Waste may also 

be placed into the bin before is pushed into the machine.  

·

  Close the door fully and press the START button, the run indicator will light 

while the ram is moving or in the down position. 

·

  The machine will not operate unless the truck is properly locked into position 

and the door is closed. 

·

  To stop the machine at any point in its cycle press the STOP button. 

 

        To restart press the START button - the machine will continue its cycle. 

·

  Continue compacting until the bag full light comes on. Bag full levels are 

dependent on the type of waste being processed. Do not overfill the bin as this 
makes it difficult to withdraw. 

·

  Bin full levels are dependant on the type of waste being processed. When full 

remove the bin at the end of the cycle, and empty the bin. 

·

 

It is recommended that if the machine is not in use for long periods it is switched 
off at the keyswitch.

 

 

OVERLOAD PROTECTION 

 

Under extreme load circumstances the Compactor might overheat. The switchgear 
contains an overload to prevent any damage to the motor. This device will 
automatically reset itself when cool, and it will only be necessary to wait a few 
minutes before the machine can be restarted.  
Press the START button to reset and start the machine. 
 
If any difficulty is encountered, please contact the supplier or the manufacturer. 

 

MAINTENANCE 

 

Keep the Compactor and the area around it clean at all times. 
 
Remove the truck and then, by releasing the castor brakes, the unit may easily be 
moved to clean the floor beneath and behind it. (NB. Switch off the electricity supply 
at the isolator or unplug the unit before moving or cleaning). 
 
It is advisable to clean the exterior stainless steel finish periodically with a stainless 
steel cleaning agent or a soapy cloth.  
 
 
 
 
 
 

Содержание IMPACTOR IP700

Страница 1: ... OPERATOR IP700 SERIES 3 Imperial Machine Company Limited Unit 1 Abbey Road Wrexham Industrial Estate Wrexham LL13 9RF Tel 44 0 1978 661155 Fax 44 0 1978 729990 Service Fax 44 0 1978 667766 Spares Fax 44 0 1978 667759 E mail info imco co uk Website www imco co uk A34 025 R3 ECN 8586 February 2017 ...

Страница 2: ......

Страница 3: ...th the protection requirements of the Electromagnetic Compatibility Directive 2004 108 EC and manufactured in accordance with harmonised standards EN 61000 6 1 2001 Immunity and EN 61000 6 3 2001 Emissions plus product specific standards They also satisfy the essential health and safety requirements of the Low Voltage Directive 2006 95 EC and are manufactured in accordance with standards BS EN 603...

Страница 4: ... INSTRUCTIONS 3 PREPARATION 4 SITING AND INSTALLATION 4 PREPARING FOR USE 4 ELECTRICAL CONNECTION 5 OPERATING 6 OVERLOAD PROTECTION 6 MAINTENANCE 6 FAULT FINDING 7 ORDERING SPARE PARTS 8 Wiring Diagram IP700 110 240V 1 phase 50 60Hz 9 Fig 1 9 Parts Illustration IP700 10 ...

Страница 5: ... Please observe these instructions carefully The guarantee applies in this form to installations within the United Kingdom Contact your Impactor supplier first RECEIVING THE UNIT UNPACKING INSTRUCTIONS Prior to unpacking check that there is no transit damage Stand the carton or crate on the end marked bottom Remove the crate panels Knock away the wooden blocks around the machine IP700 machines are...

Страница 6: ...ing and maximum cost savings Alternatively it is possible to order extra trucks for larger establishments or waste segregation Ensure that the Compactor is located on a flat and level floor Ensure that sufficient additional space is available to allow the truck to be withdrawn The front pair of castors are fitted with brakes which can be locked into position by depressing the pedal Push truck into...

Страница 7: ... free end wires marked L1 black L2 black L3 black E green yellow Fused isolator switch rated at 10 Amps per phase 3 phase 5 wire 415 3 50 220 3 50 360 440 3 50 380 415 3 50 Mains lead free end wires marked L1 black L2 black L3 black N blue E green yellow Fused isolator rated at 10 Amps per phase Note On 3 phase machines to ensure that the Power Pack Motor rotates in the correct direction connect t...

Страница 8: ...ls are dependent on the type of waste being processed Do not overfill the bin as this makes it difficult to withdraw Bin full levels are dependant on the type of waste being processed When full remove the bin at the end of the cycle and empty the bin It is recommended that if the machine is not in use for long periods it is switched off at the keyswitch OVERLOAD PROTECTION Under extreme load circu...

Страница 9: ...plug Check the electrical socket is functional 2 The machine stops with the ram in the down position and RUN indicator light on Check that the machine NORMAL CONSTANT switch is set on normal 3 The machine stops during its cycle and RUN indicator light is not lit Check door is fully closed Under extreme load condition the compactor might overheat The switchgear contains an overload to prevent damag...

Страница 10: ...on the rating plate located near the supply cable For installations outside the UK please contact your supplier For information on IMC spares and service support if applicable please call IMC on 44 0 1978 661155 Alternatively contact us via email or fax IMC Service Desk Fax 44 0 1978 667766 E mail service imco co uk IMC Spares Desk Fax 44 0 1978 667759 E mail spares imco co uk ...

Страница 11: ...IP700 9 Wiring Diagram IP700 110 240V 1 phase 50 60Hz Fig 1 ...

Страница 12: ...10 IP700 Parts Illustration IP700 Fig 2 1 2 7 4 3 5 6 8 ...

Страница 13: ...am Plate Machining Ram Guide Bearing Guide Rod Bracket L S Bracket Bracket L S Hydraulic Hose Assy Sealing Washer 3 8 BSP Male Male Fitting Lts Solent VG68 Oil Inner side L H Inner side R H Inner back Inner top front Inner back Upper Door Catch Access flap Spacer Spacer shouldered Nylon Modified screw Switch Paddle Spacer Shouldered Side Panel R H Back Panel Side Panel L H Top Cap Sound Barrier Ma...

Отзывы: