Fiber Optic Cleaning Guidelines 

Fiber Optic transmitters and receivers are extremely susceptible to contamination by 
particles of dirt or dust, which can obstruct the optic path and cause performance 
degradation.  Good system performance requires clean optics and connector ferrules. 

1.

 

Use fiber patch cords (or connectors, if you terminate your own fiber) only from 
a reputable supplier; low-quality components can cause many hard-to-diagnose 
problems in an installation. 

2.

 

Dust caps are installed at IMC Networks to ensure factory-clean optical devices.  
These protective caps should not be removed until the moment of connecting 
the fiber cable to the device.  Should it be necessary to disconnect the fiber 
device, reinstall the protective dust caps. 

3.

 

Store spare caps in a dust-free environment such as a sealed plastic bag or box 
so that when reinstalled they do not introduce any contamination to the optics. 

4.

 

If you suspect that the optics have been contaminated, alternate between 
blasting with clean, dry, compressed air and flushing with methanol to remove 
particles of dirt. 

Electrostatic Discharge Precautions 

Electrostatic discharge (ESD) can cause damage to your add-in modules.  Always 
observe the following precautions when installing or handling an add-in module or 
any board assembly. 

1.

 

Do not remove unit from its protective packaging until you’re ready to install it. 

2.

 

Wear an ESD wrist grounding strap before handling any module or component.  
If you do not have a wrist strap, maintain grounded contact with the system unit 
throughout any procedure requiring ESD protection. 

3.

 

Hold boards by the edges only; do not touch the electronic components or gold 
connectors. 

4.

 

After removal, always place the boards on a grounded, static-free surface, ESD 
pad or in a proper ESD bag.  Do not slide the board over any surface. 

 

 

WARNING!

  Integrated circuits and fiber optic components are 

extremely susceptible to electrostatic discharge damage.  Do not 
handle these components directly unless you are a qualified service 
technician and use tools and techniques that conform to accepted 
industry practices. 

Содержание McBasic-Gigabit

Страница 1: ...McBasic Gigabit Operation Manual ...

Страница 2: ...nger To receive in warranty service the defective product must be received at IMC Networks no later than the end of the warranty period The product must be accompanied by proof of purchase satisfactory to IMC Networks denoting product serial number and purchase date a written description of the defect and a Return Merchandise Authorization RMA number issued by IMC Networks No products will be acce...

Страница 3: ...ss Through 2 FX LinkLoss FXLL 2 Using FiberAlert and LinkLoss 3 Link Fault Pass Through LFPT 4 Additional Gigabit Features 5 Preferred Forced Mode 5 Installing a McBasic Gigabit 6 LED Operation 7 Installation Troubleshooting 8 Specifications 9 IMC Networks Technical Support 10 Fiber Optic Cleaning Guidelines 11 Electrostatic Discharge Precautions 11 Safety Certifications 12 ...

Страница 4: ...nnector and one SC fiber connector NOTE All McBasic Gigabit units including 1310 nm single mode TX LX 850 nm multi mode fiber TX SX and single strand versions TX SSLX will be referred to as McBasic Gigabit throughout this installation guide except where differences need to be indicated Configuration Instructions McBasic Gigabit has user configurable features located on the PCB board Please refer t...

Страница 5: ...erter receives valid link pulses it knows that the device to which it is connected is up and sending pulses and that the copper or fiber cable coming from that device is intact The appropriate LNK link LED is lit to indicate this The IMC Networks media converter also sends out link pulses from its copper and fiber transmitters but normally has no way of knowing whether the cable to the other devic...

Страница 6: ...navailable the IMC Networks device at the receiver end notes the loss of link The device will then stop transmitting data and the link signal until a signal or link pulse is received The result is that the link LED on BOTH sides of the fiber connection will go out indicating a fault somewhere in the fiber loop Using FiberAlert a local site administrator is notified of a fault and can quickly deter...

Страница 7: ...ault occurs on the remote twisted pair 2 TX LinkLoss detects the fault and disables the OPTICS or UPLINK port 3 FX LinkLoss detects the fiber loss and disables the DATA port The link fault is passed through the media conversion and is observed at each end It acts just like it would if the devices were directly connected For more information on LinkLoss FiberAlert visit the IMC Networks Web site at...

Страница 8: ... DIP Switch Feature Setting Since most switches today typically function as Masters IMC Networks recommends configuring McBasic Gigabit as indicated in the table S1 1 Preferred Forced ON Preferred FX Negotiation on McBasic Gigabit McBasic Gigabit module includes the FX Auto Negotiation feature which negotiates duplex mode This feature must be enabled or disabled on both ends of the connection or t...

Страница 9: ...cts in pairs or connect two compatible IMC Networks single strand fiber products For example connect McBasic Gigabit TX SSFX SM1310 SC which has 1310 xmt and 1550 rcv to a product which has 1550 xmt and 1310 rcv e g McGigabit TX SSFX SM1550 SC The two connected products must also have the same speed and distance capabilities i e both are single mode 20 km or both are single PLUS 40 km AutoCross Fe...

Страница 10: ...n when a twisted pair link is established Blinks green when data is detected on the port Located on RJ 45 connector Glows amber when port is operating in Full Duplex Mode on the RJ 45 connector Glows green when operating in Full Duplex Mode Glows green when TX LinkLoss is enabled on the port Glows green when a twisted pair link is established Glows green when FiberAlert is enabled ...

Страница 11: ...atures interference with testing If using a high powered device which is designed for long distance installations for a short distance installation the fiber transmitters may overdrive the receivers and cause data loss If this is the case an optical attenuator may need to be added to the connection For fiber specifications visit the IMC Networks Web site at www imcnetworks com adocs fcs asp or con...

Страница 12: ... 0 50 C Storage Temperature 130 158 F 25 85 C Humidity 5 95 non condensing Power Consumption Typical McBasic Gigabit w LFPT 100 240V AC 50 60Hz 0 2 0 1A Fiber Optic Specifications For fiber optic specifications please visit http www imcnetworks com adocs fcs asp ...

Страница 13: ...10 IMC Networks Technical Support Tel 949 465 3000 or 800 624 1070 in the U S and Canada 32 16 550880 Europe Fax 949 465 3020 E Mail techsupport imcnetworks com Web www imcnetworks com ...

Страница 14: ...e been contaminated alternate between blasting with clean dry compressed air and flushing with methanol to remove particles of dirt Electrostatic Discharge Precautions Electrostatic discharge ESD can cause damage to your add in modules Always observe the following precautions when installing or handling an add in module or any board assembly 1 Do not remove unit from its protective packaging until...

Страница 15: ...ears this symbol on product or packaging must not be disposed of with unsorted municipal waste This symbol indicates that the equipment should be disposed of separately from regular household waste It is the consumer s responsibility to dispose of this and all equipment so marked through designated collection facilities appointed by government or local authorities Following these steps through pro...

Страница 16: ...tice IMC Networks assumes no responsibility for any errors that may appear in this document McBasic Gigabit is a trademark of IMC Networks Other brands or product names may be trademarks and are the property of their respective companies Document Number 55 80913 01 A0 September 2008 If the product s part number begins with an 8 it is compliant with the Restriction of Hazardous Substances RoHS dire...

Отзывы: