About iConfig 

iConfig is an in-band configuration utility (in iView²) that lets users quickly 
and easily complete the first stages of SNMP configuration for SNMP-
manageable devices.  iConfig can set the IP address, subnet mask and default 
gateway as well as define the community strings and SNMP traps. 
 
In addition to the above functions, iConfig offers an authorized IP address 
system and access restriction to MIB groups supported by manageable 
devices.  These extra layers of security are purely optional and do not affect 
SNMP compatibility. 
 
The iConfig utility can be used to upload new versions of the system software 
and new MIB information. It also offers diagnostic capabilities for faster 
resolution of technical support issues. The default user ID for both iConfig 
and Telnet is: 
 
User: 

admin

 / Password: 

admin

 

 
The three levels of Telnet account access are: 

User 

Can only see status, change password and reboot

 

Operator 

Can perform User functions and change settings 

Administrator 

Can perform all functions and add/delete accounts and 
perform the command 

cleandb 

A Username and Password can be added in the 

USER

 tab of iConfig, or the 

Accounts

 command within Telnet or the Serial Configuration.  Admin/admin 

should not be deleted until new usernames/passwords are tested.  See page 
16 for additional information. 

 

The iConfig utility works with the following platforms: 
 

 

Windows 98 

 

Windows NT 

 

Windows 2000 

 

Windows XP 

 
The iConfig utility is available as a standalone application, as well as built in 
to the Windows version of iView² (Windows 98 users must use the 
standalone version of the iConfig utility).  Both applications are included on 

Содержание Management Module SNMP

Страница 1: ...SNMP Management Module Operation Manual...

Страница 2: ...er To receive in warranty service the defective product must be received at IMC Networks no later than the end of the warranty period The product must be accompanied by proof of purchase satisfactory...

Страница 3: ...nagement Module 1 Configuring 2 SNMP Write Lock iMediaChassis series 3 Using the SNMP Write Lock Switch 4 Using Telnet 5 About iConfig 6 About Serial Port Configuration 7 UMA Unified Management Agent...

Страница 4: ...Connect the chassis to the network by plugging one end of a CAT 5 twisted pair cable into the port labeled MGMT on the Management Module Plug the other end of the cable into a device e g switch hub et...

Страница 5: ...network assign the SNMP Management Module IP configuration information e g IP address subnet mask etc There are four ways to do this Using iConfig Using the Management Module s serial port Using DHCP...

Страница 6: ...s switch in the NORMAL position during day to day operation the LOCKED position should only be used when changing the SNMP Management Module As stated SNMP Management Modules can be removed and replac...

Страница 7: ...or details Hardware settings should be configured to match those made via SNMP Always reconfigure application modules when moving them from one chassis slot to another Using the SNMP Write Lock Switch...

Страница 8: ...t IP Address of 10 10 10 10 Changes to the Static IP Address can be added manually through iConfig an RS 232 Serial session or Telnet The changes will be initiated following reboot of the module DHCP...

Страница 9: ...cal support issues The default user ID for both iConfig and Telnet is User admin Password admin The three levels of Telnet account access are User Can only see status change password and reboot Operat...

Страница 10: ...n 50 feet 15 24 meters Plug one end of the cable into the DB 9 connector and the other into the appropriate port on the computer terminal Set the computer terminal for VT 100 emulation The serial port...

Страница 11: ...d Parameter Values P Change Password T New Trap Destination K Remove ALL Trap Destinations C New Community String U Delete ALL Community Strings D Enable Disable DHCP E End Session Space Bar Device Sp...

Страница 12: ...acters no spaces and press Enter Then type one of the following to assign the community string s access rights R read only access W read write access Enter abort Press Enter When finished press Enter...

Страница 13: ...r Enabling Disabling DHCP To Enable Disable DHCP press D and then type reboot for the changes to take effect Refer to page 5 for more information Ending a Session When ending a session press E before...

Страница 14: ...splays the task list with priorities memory Displays the memory usage cleandb Removes all information in the database except the IP address of the device download Opens the Download dialog box where t...

Страница 15: ...w for management integrate the SNMP vendor MIBs which can be found in the MIB directory on the CD or the subdirectory of iView installed on the chosen hard drive of a workstation MCIMCV2c MIB Refer to...

Страница 16: ...Office CO then connect each to a remote iMcV FiberLinX II unit installed at the customers premise CPE UMA will then allow users to manage all 41 devices including the chassis at the CO via a single I...

Страница 17: ...re in process Manage up to 41 devices with a single IP address Telnet access and view for all system devices Only one Ethernet port is required reducing the number of ports used on a network switch Fi...

Страница 18: ...MetroFiber 3 represent Host iMcV FiberLinX II units while the devices listed on the right Irvine POP 3 represent Remote iMcV FiberLinX II units The names SNMP sysName given to each iMcV FiberLinX II...

Страница 19: ...24 x 768 Resolution or higher Please consult the iView CD for installation information The Help tab in iView provides assistance in configuring managing modules Passwords Passwords are a way to make t...

Страница 20: ...624 1070 in the U S and Canada 32 16 550880 Europe Fax 949 465 3020 E Mail techsupport imcnetworks com Web www imcnetworks com Specifications Environmental Operating Temperature 32 104 F 0 40 C Storag...

Страница 21: ...maintain grounded contact with the system unit throughout any procedure requiring ESD protection 3 Hold boards by the edges only do not touch the electronic components or gold connectors 4 After remo...

Страница 22: ...EC WEEE requires that any equipment that bears this symbol on product or packaging must not be disposed of with unsorted municipal waste This symbol indicates that the equipment should be disposed of...

Страница 23: ...20 Notes...

Страница 24: ...tice IMC Networks assumes no responsibility for any errors that may appear in this document IE MediaChassis 2 is a trademark of IMC Networks Other brands or product names may be trademarks and are the...

Отзывы: