About the iMcV-Modules 

iMcV-Modules are SNMP-manageable and install in the modular, SNMP-manageable 
iMediaChassis series in the unmanaged MediaChassis series.  The following media 
conversion and fiber mode conversion iMcV Modules are described in this manual: 

iMcV-PIM

 

Ethernet module providing a single conversion between 10Base-T twisted 
pair and 10Base-FL single-mode or multi-mode fiber.  Each iMcV-PIM 
includes one RJ-45 connector and one pair of ST or SC fiber optic 
connectors.  

When connecting 10 Mbps iMcV-PIM Media Converters, the 

end devices must be set to Force mode. 

TP LinkLoss and FO LinkLoss are always enabled—please see the table later 
in this manual. 

iMcV-LIM 

Fast Ethernet module provides a single conversion between 100Base-TX 
twisted pair and 100Base-FX/SX single-mode or multi-mode fiber.  Each 
iMcV-LIM includes one RJ-45 connector and one pair of ST or SC fiber optic 
connectors. 

Also available in a single-strand fiber version, iMcV-LIM TX/SSFX allows two 
wavelengths to share one fiber strand – Full-Duplex data travels on different 
wavelengths (1310 nm and 1550 nm) – doubling the capacity of fiber.  
Includes one RJ-45 connector and one SC fiber connector. 

iMcV-S2MM/ 
M2MM/S2SM 

Protocol-independent modules provide a single conversion between single-
mode and multi-mode (S2MM*) fiber, 1310 nm to 1550 nm single-mode 
(S2SM), or 850 nm to 1300 nm multi-mode (M2MM).  Supported 
transmission speeds are:  10-155 Mbps and 622-1250Mbps.  Each module 
includes two pairs of ST or SC fiber optic connectors (or small form factor 
connector).  Single-strand fiber versions also available. 

For information about other iMcV-Modules, refer to their respective manuals and 
datasheets on the IMC Networks web site at:  

http://www.imcnetworks.com/tech/techsup.asp

  

Installation 

iMcV-Modules install in any IMC Networks SNMP-manageable iMediaChassis series 
or in any MediaChassis.  To install an iMcV-Module, remove the blank bracket 
covering the slot where the module is to be installed by removing the screw on the 
outside edge of the bracket.  Slide the iMcV Module into the chassis, via the card 
guides, until the module is seated securely in the connector.  Secure the module to 
the chassis by tightening the captive screw.  Save any blanks removed during 
installation for future use should configuration requirements change. 

Содержание iMcV-S2MM/1250

Страница 1: ...iMcV Modules Operation Manual Above illustrations are representative some minor differences may be present in actual product...

Страница 2: ...ructions and directions for a period of six 6 years after the original date of purchase This warranty is subject to the limitations set forth below At its option IMC Networks will repair or replace at...

Страница 3: ...arranty ii About the iMcV Modules 1 Installation 1 LED Operation 2 Configuration Instructions 4 Installation Troubleshooting 9 Specifications 9 IMC Networks Technical Support 10 Fiber Optic Cleaning G...

Страница 4: ...rent wavelengths 1310 nm and 1550 nm doubling the capacity of fiber Includes one RJ 45 connector and one SC fiber connector iMcV S2MM M2MM S2SM Protocol independent modules provide a single conversion...

Страница 5: ...reen when unit has power LNK RJ 45 Glows green if link is established on the twisted pair port located on RJ 45 ACT RJ 45 Glows amber when data is being passed on the twisted pair located on RJ 45 LNK...

Страница 6: ...data FA Glows green when FiberAlert is enabled FiberAlert is not available applicable on single strand versions of iMcV LIM LEDs on iMcV S2MM S2SM M2MM The LED functions on iMcV S2MM S2SM M2MM are as...

Страница 7: ...naged chassis is configured via the software it will operate using the hardware configuration Unmanaged Modules Before beginning installation of the iMcV Modules configure them for the desired feature...

Страница 8: ...t and Pulsing FiberAlert Some iMcV Modules include advanced troubleshooting features that help locate silent failures on the network Troubleshooting features include iMcV LIM TX FX and TX SSFX 30 Boar...

Страница 9: ...transmitters but normally has no way of knowing whether the cable to the other device is intact and the link pulses are reaching the other end The combination of FiberAlert and LinkLoss allows this in...

Страница 10: ...the loss of one strand of fiber If a strand is unavailable the IMC Networks device at the receiver end notes the loss of link The device will then stop transmitting data and start sending link pulses...

Страница 11: ...connection set the push button to a position that makes the twisted pair LNK link LED glow Auto Negotiation on iMcV LIM iMcV LIM Modules include the feature Auto Negotiation When Auto Negotiation is...

Страница 12: ...r by itself first make sure to have an appropriate fiber patch cable then follow these steps to test 1 Connect the media converter to the twisted pair device with a twisted pair cable 2 Loop a single...

Страница 13: ...10 IMC Networks Technical Support Tel 949 465 3000 or 800 624 1070 in the U S and Canada 32 16 550880 Europe Fax 949 465 3020 E Mail techsupport imcnetworks com Web www imcnetworks com...

Страница 14: ...between blasting with clean dry compressed air and flushing with methanol to remove particles of dirt Electrostatic Discharge Precautions Electrostatic discharge ESD can cause damage to any product a...

Страница 15: ...f separately from regular household waste It is the consumer s responsibility to dispose of this and all equipment so marked through designated collection facilities appointed by government or local a...

Страница 16: ...The information in this document is subject to change without notice IMC Networks assumes no responsibility for any errors that may appear in this document iMcV Modules is a trademark of IMC Networks...

Отзывы: