5
Host (CO) Module Configuration
To allow the HOST (CO) Control Office IE-iMcV-VDSL2-LANextender module to
manage the remotely connected CPE IE-iMcV-VDSL2-LANextender unit, set DIP
Switch #1 to the OFF position (default setting). This selection can only be performed
manually and cannot be overridden by software settings.
A Host configured CO IE-iMcV-VDSL2-LANextender module must be installed in a
managed chassis to allow SNMP management through iView
²
. The iMediaChassis
series, available in 3, 6 and 20 slots with an optional SNMP Management Module, is
recommended. Please refer to the section SNMP Management.
Remote (CPE) Module Configuration
To configure a CPE IE-iMcV-VDSL2-LANextender module as a Remote CPE, set DIP
Switch #1 to the ON position (OFF is the default setting).
A Remote CPE configured IE-iMcV-VDSL2-LANextender module can be installed in
an unmanaged chassis. These chassis can include the IE-MediaChassis series chassis,
the MediaChassis series chassis, the iMediaChassis series chassis with the optional
SNMP agent management module removed.
DATA Port Features
The 10/100BaseT DATA port on the IE-iMcV-VDSL2-LANextender Auto Negotiates
for speed and duplex mode. These modules also provide the option of manually
setting the speed and duplex mode if the connected devices do not have the ability
to Auto Negotiate, or when Auto-Negotiation is not desired by configuring using DIP
Switches #8 and #9.
Auto Negotiation
The IE-iMcV-VDSL2-LANextender ships from the factory with Auto Negotiation
enabled on the DATA port. In this mode, the DATA port negotiates for speed and
duplex (i.e. the module detects 10 Mbps Full-Duplex, 10 Mbps Half-Duplex, 100
Mbps Full-Duplex or 100 Mbps Half-Duplex with Flow Control). Configure Auto-
Negotiation on an IE-iMcV-VDSL2-LANextender by adjusting the DIP Switch #5 (for
unmanaged modules) or via the management software (for managed modules).