3

 

Fiber Optic Cleaning Guidelines 

Fiber Optic transmitters and receivers are extremely susceptible to contamination by 
particles of dirt or dust, which can obstruct the optic path and cause performance 
degradation.  Good system performance requires clean optics and connector ferrules. 

1.

 

Use fiber patch cords (or connectors, if you terminate your own fiber) only from 
a reputable supplier; low-quality components can cause many hard-to-diagnose 
problems in an installation. 

2.

 

Dust caps are installed at IMC Networks to ensure factory-clean optical devices.  
These protective caps should not be removed until the moment of connecting 
the fiber cable to the device.  Should it be necessary to disconnect the fiber 
device, reinstall the protective dust caps. 

3.

 

Store spare caps in a dust-free environment such as a sealed plastic bag or box 
so that when reinstalled they do not introduce any contamination to the optics. 

4.

 

If you suspect that the optics have been contaminated, alternate between 
blasting with clean, dry, compressed air and flushing with methanol to remove 
particles of dirt. 

Electrostatic Discharge Precautions 

Electrostatic discharge (ESD) can cause damage to any product, add-in modules or 
stand alone units, containing electronic components.  Always observe the following 
precautions when installing or handling these kinds of products 

1.

 

Do not remove unit from its protective packaging until ready to install. 

2.

 

Wear an ESD wrist grounding strap before handling any module or component.  
If the wrist strap is not available, maintain grounded contact with the system unit 
throughout any procedure requiring ESD protection. 

3.

 

Hold the units by the edges; do not touch the electronic components or gold 
connectors. 

4.

 

After removal, always place the boards on a grounded, static-free surface, ESD 
pad or in a proper ESD bag.  Do not slide the modules or stand alone units over 
any surface. 

 

 

WARNING!

  Integrated circuits and fiber optic components are 

extremely susceptible to electrostatic discharge damage.  Do not 
handle these components directly unless you are a qualified service 
technician and use tools and techniques that conform to accepted 
industry practices. 

Содержание Giga-MiniMc

Страница 1: ...Giga MiniMc Operation Manual ...

Страница 2: ...nger To receive in warranty service the defective product must be received at IMC Networks no later than the end of the warranty period The product must be accompanied by proof of purchase satisfactory to IMC Networks denoting product serial number and purchase date a written description of the defect and a Return Merchandise Authorization RMA number issued by IMC Networks No products will be acce...

Страница 3: ...ement i Warranty i About the Giga MiniMc 1 Installing the Giga MiniMc 1 Powering the Giga MiniMc 1 LED Operation 1 IMC Networks Technical Support 2 Specifications 2 Fiber Optic Cleaning Guidelines 3 Electrostatic Discharge Precautions 3 Safety Certifications 4 ...

Страница 4: ...rTray 18 or can be used as a standalone media converter As a standalone the Giga MiniMc uses a universal external switching power cube with 100 240 10 VAC input and 5V DC output Powering the Giga MiniMc The Giga MiniMc includes multiple powering options A country specific high reliability AC power adapter included The IEEE 802 3af Power over Ethernet standard draws power from power sourcing equipm...

Страница 5: ...cifications Ethernet Connections 10 100 1000 BaseT Auto Negotiation Auto Cross Flow Control 1536 MTU Full Line Rate Forwarding AC Wall Adapter 100 to 240 10 V AC input 5V DC output 2A max Operating Temperature 32 to 122 F 0 to 50 C Storage Temperature 31 to 167 F 35 to 75 C Humidity 5 to 95 non condensing 0 to 10 000 ft altitude Dimensions 0 83 H x 1 80 W x 3 35 D 2 11 x 4 57 x 8 51 cm ...

Страница 6: ...etween blasting with clean dry compressed air and flushing with methanol to remove particles of dirt Electrostatic Discharge Precautions Electrostatic discharge ESD can cause damage to any product add in modules or stand alone units containing electronic components Always observe the following precautions when installing or handling these kinds of products 1 Do not remove unit from its protective ...

Страница 7: ...ears this symbol on product or packaging must not be disposed of with unsorted municipal waste This symbol indicates that the equipment should be disposed of separately from regular household waste It is the consumer s responsibility to dispose of this and all equipment so marked through designated collection facilities appointed by government or local authorities Following these steps through pro...

Страница 8: ...The information in this document is subject to change without notice IMC Networks assumes no responsibility for any errors that may appear in this document Giga MiniMc is a trademark of IMC Networks Other brands or product names may be trademarks and are the property of their respective companies Document Number 56 80630 00 A2 January 2010 ...

Отзывы: