background image

Command List

•  

I

= Enter New Saved Parameter Values

•  

= Change Password 

•  

T

= New Trap Destination

•  

K

= Remove ALL Trap Destinations 

• 

C

= New Community String

•  

U

= Delete ALL Community Strings 

•  

E

= End Session

NOTE:

You must reboot after making any modifications to the Saved

Values or changes will not take effect.  To reboot, type the word

“

Reboot

” (no quote marks) at the prompt on the main configuration

screen, or turn the device’s power OFF then ON again.

NOTE:

Because the Delete key does not work on VT-100 terminal

emulators, use the F2 key instead.

Assigning TCP/IP Information

To modify the Saved Parameter Values (i.e., assign IP address and subnet

mask), press

I

.  You will be instructed to enter the IP address and subnet

mask for the connected device.  Press 

Enter

after each.  You may also assign

a default gateway, if desired (press 

Enter

to skip).  

When finished, press 

Enter

, then type “

Reboot

” for changes to take

effect.  The Saved Values and Current Values should now both display the

changes made (e.g., new IP address and subnet mask).

Creating Community Strings

The default community string is named “public” and has read/write

access.  For security reasons, IMC Networks recommends you set up two

communities: one with read-only only (for general use), the other with

read/write access (for the administrator). 

To create a new community string, go to the main configuration screen

and press 

C

.  Enter the name of the new community (up to 16 characters,

no spaces allowed) and press 

Enter

. Then type one of the following options

to assign the community string’s access rights:

•  

R

= read-only access

•  

W

= read/write access

•  

Enter

= abort 

Press 

Enter

.  

Ap.2

All manuals and user guides at all-guides.com

Содержание FiberLinX

Страница 1: ...10 2611 USA TEL 949 465 3000 FAX 949 465 3020 www imcnetworks com FiberLinX Installation Manual and User Reference Guide Document Number 50 80111 01 A0 February 2000 All manuals and user guides at all...

Страница 2: ...n which is protected by copyright No part may be reproduced in any way without prior consent of IMC Networks Copyright 1999 2000 IMC Networks All rights reserved Trademarks FiberLinX is a trademark of...

Страница 3: ...Ds for the Fiber Data Port 2 5 LEDs for the Twisted Pair Data Port 2 5 LEDs for the Twisted Pair Management Port 2 5 DB 9 Serial Connector 2 6 Chapter 3 Configuring and Managing FiberLinX Required Man...

Страница 4: ...ge Precautions 5 1 Unit Specifications 5 2 Environmental 5 2 Power 5 2 Heat 5 2 Fiber Optic 5 2 Chapter 6 General Information Technical Support 6 1 Warranty 6 1 Federal Communications Commission Radio...

Страница 5: ...affic i e the management port NOTE Although the management port is designed to accept SNMP traffic ANY port on the FiberLinX Module can be configured to serve as the SNMP management port NOTE The twis...

Страница 6: ...connectors FiberLinX SingleMode PLUS as above with higher power budget How FiberLinX Works Each port on the FiberLinX includes its own MAC Address The movement of data from one port to another is acco...

Страница 7: ...ne operation 2 Installation of a PowerChassis 100 Series chassis 3 Installation of the FiberLinX Module into the above mentioned PowerChassis and 4 Selecting a crossover or pass through connection for...

Страница 8: ...or management traffic you can configure FiberLinX to accept SNMP management traffic from any of its three ports There are four different ways you can configure FiberLinX to accept or not accept SNMP m...

Страница 9: ...roubleshooting feature that assists in pinpointing link faults between media conversion products If a media converter is not 2 3 S N M P M A N A G E M E N T T R A F F I C D I P S W I T C H E S Switch...

Страница 10: ...FiberLinX Modules may be safely installed or removed with power on i e FiberLinX Modules are hot swappable Please read the electrostatic discharge precautions on page 5 1 of this manual before proceed...

Страница 11: ...nX features diagnostic LEDs for each port The following illustration shows the location of the LEDs on FiberLinX LEDs for the Fiber Data Port LED functions for the fiber data port are as follows FDX G...

Страница 12: ...d to one another i e Host and Remote DB 9 Serial Connector FiberLinX features a DB 9 serial connector located above the module name on the faceplate This connector can be used as a serial port connect...

Страница 13: ...PC 4 Integration of IMC Networks MIB files into the SNMP management software NOTE If using iView this will be done for you automatically Otherwise refer to your NMS s documentation and see the sectio...

Страница 14: ...HUBCTRL32 works with the following platforms Windows NT Windows 98 HUBCTRL32 can be found on the iView CD or you can download it from the IMC Networks Web site www imcnetworks com tech software htm Fo...

Страница 15: ...X you can use its virtual faceplate display s to remotely manage your FiberLinX unit s Note that within iView for FiberLinX the only end user configuration options are creating descriptions for the un...

Страница 16: ...ave a function known as MIB COMPILER This function reads in the MIB information and converts it into machine readable format In order to successfully manage FiberLinX with your chosen application the...

Страница 17: ...fiber based switch All SNMP management traffic and data traffic goes straight into the switch at the Central site via the fiber port SNMP management traffic is imbedded within the corporate network b...

Страница 18: ...anagement traffic through the fiber data port Note that the twisted pair management ports on both FiberLinX remain unused NOTE You can access and manage the Remote site s FiberLinX directly in this co...

Страница 19: ...e following illustration shows an external hub being used to maintain LAN separation Configure the two FiberLinX units used in this example exactly as the ones in Example 2 except direct management tr...

Страница 20: ...4 4 All manuals and user guides at all guides com...

Страница 21: ...dirt as possible 3 Store spare caps in a dust free environment such as a sealed plastic bag or box so that when reinstalled they do not introduce any contamination to the optics 4 Should it be necess...

Страница 22: ...nnectors 4 After removal always place the boards on a grounded static free surface ESD pad or in a proper ESD bag Do not slide the board over any surface Unit Specifications Environmental Operating Te...

Страница 23: ...amaged by unreasonable use accident negligence service or modification by anyone other than an authorized IMC Networks Service Technician or by any other causes unrelated to defective materials or wor...

Страница 24: ...NETWORKS MAKES NO OTHER WARRANTIES WHETHER EXPRESS OR IMPLIED WITH RESPECT TO THIS IMC NETWORKS PRODUCT INCLUDING WITHOUT LIMITATION ANY SOFTWARE ASSOCIATED OR INCLUDED IMC NETWORKS SHALL DISREGARD A...

Страница 25: ...harmful interference in which case the user will be required to correct the interference at his own expense Any changes or modifications not expressly approved by the manufacturer could void the user...

Страница 26: ...6 4 All manuals and user guides at all guides com a l l g u i d e s c o m...

Страница 27: ...set for 38 4K BAUD 8 data bits 1 stop bit no parity no flow control Main Configuration Screen After running through an initial self test the screen will display the following message Press Enter for...

Страница 28: ...device Press Enter after each You may also assign a default gateway if desired press Enter to skip When finished press Enter then type Reboot for changes to take effect The Saved Values and Current Va...

Страница 29: ...f you want to be able to selectively activate and de activate traps use HUBCTRL32 to configure your device Removing Traps To remove all trap destinations press K You will then be asked if you really w...

Страница 30: ...echsupport imcnetworks com for more information Downloading HUBCTRL32 From the IMC Networks Web site 1 Download the file hubctrl32 exe from IMC Networks Web site The file can be found under the sectio...

Страница 31: ...ear Here the utility will create a Program group and icons for HUBCTRL32 from the Windows Start menu The default name of this Program group will be Hub Control32 To change this name highlight Hub Cont...

Страница 32: ...tall the new driver G Restart the system to complete the HUBCTRL32 installation For Windows NT Network Control Panel Application You MUST have Administrator rights to perform the following steps If yo...

Отзывы: