Assembly/Operation Instructions

(1) This transformer has been built into the machine

Note: The voltage of this product has been adjusted to 110V. Please make

sure that the voltage in your area is suitable.

The voltage of the transformer is

adjustable. We have adjusted the transformer to 110V before leaving the

factory to ensure the smooth operation of the machine. (If 220V is required,

please purchase the corresponding model)

Important: Make sure the converter is suiting your local power voltage.

(2) Tighten the screw below the compressor. Install the hose and tighten the

release valve

(3) Connect the compressor filling hose to the air tank or other devices.

(4) Turn on the compressor fan by press the switch (Right side button); Let the

compressor fan running around 2 minutes. Turn on the compressor (Left side

button)

IMPORTANT: Fan work first, then compressor.

Содержание TXET062-1

Страница 1: ...4500 PSI 300Bar Built in Conveter 12V Air Compressor Instruction Manual 12V compressor VI Series TXET062 1 Shutoff compressor manually TXET062 2 Shutoff compressor automatically Rev 1 1 2020...

Страница 2: ...d reassembly will result in leaks damage and may void your warranty 6 Never attempt to dismantle any portion of this compressor when it is pressurized or is hot after running 7 This compressor is desi...

Страница 3: ...3 Contents Specifications 4 Assembly Operation Instructions 5 6 TXET062 2 model function 7 Maintenance 8 Troubleshooting 9 10 After sales contact information 11...

Страница 4: ...n transformer Size 33 26 5 33 5cm 13 10 43 13 19 inch Weight 9 5KG 20 9lb Working pressure 4500PSI 30Mpa 300Bar Cooling system Fan cooling Charging rate 20min 0 45L tank Motor power rating 250W OEM YE...

Страница 5: ...re the smooth operation of the machine If 220V is required please purchase the corresponding model Important Make sure the converter is suiting your local power voltage 2 Tighten the screw below the c...

Страница 6: ...DC power source Red connects to the positive terminal and black connects to the negative terminal When connected correctly the compressor fan will start automatically Otherwise the cooling fan will no...

Страница 7: ...3 Picture D it shows when it reaches the pressure we set it can shutoff automatically IMPORTANT Don t set the output pressure above 4500PSI 300Bar 4 When running the compressor it shows the starting...

Страница 8: ...nce it 1 Mainly clean these 4 connections it can reduce the chance of malfunctioning 2 Replace the filter cotton core inside we have put extra cotton fillers in our packing list 3 Drain the waste oil...

Страница 9: ...a 12V battery make sure the jumper cables are properly connected Issue Compressor cannot reach high pressure air Possible 1 Air leaking 2 Seal balls problem Resolution 1 Check all joints connections...

Страница 10: ...the corresponding check valve Issue Operating temperature too high Possible 1 long time use or bad ventilation 2 Fan rotary direction Resolution 1 No let the compressor continuously work cool the comp...

Страница 11: ...questions please contact us to solve we will be happy to provide you with the best and highest quality service Thank you for your purchase Email support imaycc service com IMAYCC band make your outdoo...

Страница 12: ......

Отзывы: