Number
of
cells
Number
of
cells
DEC
DEC
LiPo STORAGE
2.0A 11.1V(3S)
LiPo FAST CHG
2.0A 11.1V(3S)
Li3S 2.0A 12.59V
STO 022:43 00682
Li3S 2.0A 12.59V
FAS 022:43 00682
-
-
Batt type
Stop
Batt type
Stop
Elapsed
time
Elapsed
time
INC
INC
+
+
Charge
or discharge
current
Charge
current
Supplied
capacity
Supplied
capacity
DEC
DEC
Start
Enter
Start
Enter
-
-
‘>3 seconds’
‘>3 seconds’
INC
INC
+
+
Current
voltage
battery
Current
voltage
battery
Storage control of Lithium battery
This function is for charging/discharging batteries which are not used at
once. This program is designed for charging or discharging of batteries of
specific original state. They are classified by types: 3.75V Lilo, 3.85V LiPo
and 3.3V LiFe. The program will begin to discharge if the original state of
the battery exceeds the voltage level of storage.
At this screen, you can set up
the current and voltage of the
battery pack. Charging and
d i s c h a r g i n g w i l l m a k e t h e
batteries come to the voltage
level of “storage” state.
This screen shows the real-
time status charging. Press
BATT TYPE/STOP key once to
stop the charge process.
Charging current will become lower
when it progress to the end of
charging. A specific CV process will
be reduced to end the charging
process earlier. In fact, the charging
current will goes to 1/5 when the
charging process comes to 1/10.
Charging capacity will be a little
smaller than normal charging, but
charging time will be shortened
accordingly.
You can set up the charging current
and voltage of the battery pack.
Press START/ENTER key to display
voltage confirmation. Then press
START/ENTER key again to confirm
and begin to charge.
This screen shows the real-time
status of “fast charging”. Press
BATT TYPE/STOP key once to stop
the charge process.