46
Appendix A: Default Settings Table
Parameter name
Default settings
Remark
Code setting
Code function setting
Enable
Send out code setting info
Do not send out
Communication setting
Keyboard
TTL
-
232
Stop bit
Baud rate
9600
Check
No check
Data bit
8 bits
Stop bit
1 bit
Hardware flow control
No
HID
-
KBW
HID
-
KBW Keyboard layout
USA keyboard
HID
-
KBW Delay between
the keys
2ms
Polling rate
1ms
Mode Parameters
The default mode of reading
Trigger mode
Can be selected as batch mode,
trigger mode, induction mode,
continuous mode.
Trigger mode
Single reading time
3000ms
Setting range
:
1000~3600000ms
Trigger condition
Level
Same reading delay
No Delay
Rereading timeout reset
No
Same reading delay time
1500ms
I
nduction
mode
Single reading time
3000ms
Setting range
:
1000~3600000ms
Stabilizing the image time
60ms
Setting range
:
0~1600ms
Same reading delay
No Delay
Rereading timeout reset
No
Same reading delay time
1500ms
Setting range
:
0~65535ms
Scenario
changes
threshold values
10
Setting range
:
1~50
C
ontinuous
mode
Single reading time
3000ms
Setting range
:
1000~3600000ms
reading interval time
1000ms
Setting range
:
0~65535ms
Same reading delay
No delay
Rereading timeout reset
No
Same reading delay time
1500ms
Setting range
:
0~65535ms