DFK 33UX252 Technical Reference Manual
37
Camera Controls
Parameter
White Balance Temperature
Minimum
2500 K
Maximum
10000 K
Default
auto
USB3 Vision: GenICam
BalanceWhiteTemperature
Video4Linux2
White Balance Temperature
VCD Property
VCDID_WhiteBalance
\VCDElement_WhiteBalanceTemperature
Parameter
White Balance Temperature Preset
Sodium-Vapor Lamp
2500 K
Warm Light
2700 K
Halogen Light
3000 K
Neutral White
3500 K
Cool White
Fluorescent Light
4000 K
Cool White/Daylight
(CFL)
5000 K
Daylight
6000 K
Cool White LED
7500 K
Blue Sky
10000 K
USB3 Vision: GenICam
BalanceWhiteTemperaturePreset
Video4Linux2
Whitebalance Temperature Preset
VCD Property
VCDID_WhiteBalance
\VCDElement_TemperaturePreset
5.9
Image Processing
5.9.1
Gamma
The 33U series cameras can perform gamma correction on the image data. If the pixel
format of a color camera is set a YUV mode, gamma correction is applied to the Y
channel. In bayer raw and RGB24 modes, all color channels are subject to the same
gamma correction.