![Imaging Source DFK 33UX252 Скачать руководство пользователя страница 21](http://html1.mh-extra.com/html/imaging-source/dfk-33ux252/dfk-33ux252_technical-reference-manual_2045448021.webp)
DFK 33UX252 Technical Reference Manual
21
Camera Controls
Parameter
Partial Scan Auto Center
On
Automatically configure Partial Scan Offset X/Y so that
the center area of the sensor is read out
True
Off
Control Partial Scan Offset X/Y manually
False
USB3 Vision: GenICam
OffsetAutoCenter
Video4Linux2
ROI Auto Center
VCD Property
VCDID_PartialScanOffset
\VCDElement_PartialScanAutoCenter
5.1.6
Image Flipping
The DFK 33UX252 camera allows flipping of the image data horizontally, vertically, or
both. The
Flip Horizontal
and
Flip Vertical
parameters can be used to control this sensor
feature.
Parameter
Flip Horizontal
True
Image data is flipped horizontally
False
Image data is not flipped horizontally
USB3 Vision: GenICam
ReverseX
Video4Linux2
Flip Horizontal
VCD Property
VCDID_FlipHorizontal\VCDElement_Value
Parameter
Flip Vertical
True
Image data is flipped vertically
False
Image data is not flipped vertically
USB3 Vision: GenICam
ReverseY
Video4Linux2
Flip Vertical
VCD Property
VCDID_FlipVertical\VCDElement_Value
5.2
Image Sensor Control
5.2.1
Exposure Time
The
Exposure Time
parameter defines the time the camera opens its (electronic) shutter
when it is taking an image.