Appendix B
Servicing
148
Cover Removal and Replacement
The X100 features a separate top cover and front panel control assembly. Follow the steps
listed below:
Top Cover
1
Disconnect both AC power cords.
WARNING: You can receive an electric shock from exposed parts of the power
supplies. Ensure that you remove AC power from both power supplies before you
open the cover.
2
Remove the 16 screws from the top cover, but do not remove the back corner screws.
(
Figure B-1.
Removal of Screws from Top Cover
3
Lift the cover straight up and off the frame.(
The power supplies are now accessible for servicing.
Figure B-2.
Removal of Top Cover
Do not
remove this
screw.
Do not
remove this
screw.
FRONT