Upgrading Module Firmware
All module firmware upgrades are activated in the frame controller section of the Selenio user interface.
Follow this path to find the appropriate parameters: Configuration > Frame Controller > Configuration
tab > Upgrade Firmware.
See the Selenio frame manual for information on how to upgrade module firmware.
In the unlikely event of an upgrade failure, use the Upgrade Failure Instructions of this manual.
Upgrade Failure Instructions
The SEL‐1DEC1 and SEL‐1DEC2 modules include one user‐configurable DIP switch array (SW2), located at
the card edge next to the extractor. In normal operation, all four switches are in the Off position. In the
unlikely event of corrupted software, you may need to temporarily change the setting of Switch 1 for
the failsafe mode override. You would be alerted to this problem if a System Recovery Upgrade
Required fault was triggered after an upgrade, and the module had finished rebooting.
If a System Recovery Upgrade Required fault is triggered, you should first try using the alternate
firmware (see Activating Alternate Firmware in the Selenio frame manual) and then attempt the
upgrade again. If this second attempt fails, follow these steps to activate the failsafe mode:
1.
Remove the module from the frame and then push Switch 1 to the On position (see Figure ).
Figure 8:
DIP Switch Setting for Failsafe Mode
2.
Reinsert the module.
3.
Install the new module software using the Selenio user interface.