Page
26
of
28
430-044
APPENDIX B
WINDOWS™ TCP/IP SET-UP AND TROUBLESHOOTING
The Imagenex Model 881L-GS sonar system consists of an underwater sonar head connected via Ethernet
directly (or indirectly) to a Windows
©
based computer.
This document covers the necessary setup procedures to enable your Windows
©
10 based PC to communicate with
the sonar.
Ethernet Cable
The included Ethernet cable specifications are:
•
Cat 5e
•
RJ-45
•
568B wiring scheme
If this cable needs to be replaced, ensure that the above specifications are met.
TCP/IP Setup
The sonar head needs to run with a static IP (Internet Protocol) address for both head and PC. The IP Address of
the PC must be set to 192.168.0.X where X is any number excluding 1, 5 and 255:
IP Address
192.168.0.X
Subnet Mask
255.255.255.0
Note: the number ‘1’ is reserved for a network server ‘5’ is reserved for the 881L-GS sonar head, and 255 is
reserved for broadcasting.