WATER CHEMISTRY

CAUTION: The chemicals used to maintain the pH
balance of the water and to sanitize the water can
be dangerous. Always follow these basic guide-
lines when handling the chemicals:
1. Always read and follow the directions on the

label, unless directed otherwise.

2. Never mix different chemicals.
3. Do not exceed the recommended amounts of

chemicals—follow the directions on the label. 

4. Keep all chemicals out of the reach of children

and pets.

5. Keep containers closed tightly when not in use.
6. Never add water to the chemicals—always add

the chemicals to the water as directed.

7. Always store chemicals in a cool, dry place.

MAINTAINING THE PROPER PH BALANCE

The pH factor is a measure of the relative acidity or
alkalinity in the water. It is measured on a scale of 1
to 14. Pure water has a value of 7, which is neutral.
Any value above 7 is alkaline, and any value below 7
is acidic. You should maintain a slightly alkaline pH
level, between 7.2 and 7.8, in the hydrotherapy spa. 

Severe problems can occur when the pH balance is
not maintained within this range. If the pH level
exceeds 7.8, dissolved minerals can build up and clog
the plumbing in the spa jet unit. If the pH level falls
below 7.2, the acid level in the water will begin to cor-
rode the metal parts in the spa jet unit. Also, the sani-
tation agents in the water will not be effective if the pH
level is not properly maintained. Damage caused by
improper pH levels is not covered under the warranty.

To maintain the proper pH level, you should test the
pH of the water regularly. To test the water, purchase
a pH test kit at a pool and spa supplier. The pH read-
ing should be between 7.2 and 7.8. If the level is too
low, add a pH increaser (usually soda ash). If the
level is too high, add a pH reducer (usually sodium
bisulfate). Test the water again after five minutes. See
the instructions with your pH test kit for additional
information about testing and adjusting the pH.

CHANGING THE FILTER CYCLE

The spa will filter the water every 12 hours. The dura-
tion of the cycle can be adjusted to last 2–5 hours.
Press the temp up or temp down button on the con-
sole. When the display begins to flash, press the
pump 1 button. The display will read F2. To change
the time, press the temp up button until the desired
time is reached. Press the pump 1 button to comfirm
the selection. As spa usage increases, the duration of
the filter cycle must be increased.

ATTACHING AND REMOVING ACCESS PANELS

To locate the access panels, refer to the drawing on
page 6. Turn off the power to the spa. To remove an
access panel, first remove the four indicated screws.
Slide the access panel down and then pull the bottom
of it away from the spa. Note: Be careful not to
damage the spa shell as you remove the access
panel.

To re-attach the access panel, insert the top of the
access panel under the edge of the spa shell. Slide
the access panel up until the bottom of the access
panel clears the trim along the bottom of the spa.
Then, slide the access panel into place and re-attach
the four screws.

DRAINING THE HYDROTHERAPY SPA

The hydrotherapy spa should be drained at least four
times a year and refilled with clean water. You may
need to drain the spa more often, depending on the
user load. This must be done because after repeated
chemical treatment the water becomes chemically
saturated. Once this happens, additional chemical
treatment of the water is no longer effective. The spa
should also be drained if you will not be using it for
long periods of time. The spa must always be drained
before major repairs are made.

The hydrotherapy spa should always be covered
when it is empty. Direct sunlight can cause exten-
sive damage. The surface of the spa shell can
reach temperatures as high as 150°F in a matter of
minutes if exposed to the sun while it is empty.
These high temperatures can cause significant
damage, such as blistering of the shell surface and
warping of the spa shell. Any damage caused by
sun exposure is not covered under warranty.

Screws 

Screws 

Long

Access Panel 

Содержание IMSB61502

Страница 1: ...mmediate assis tance free of charge to you CUSTOMER HOT LINE 1 877 897 7493 Mon Fri 6 a m 6 p m MST CAUTION Read all precautions and instruc tions in this manual before using this equipment Save this manual for future reference Visit our website at www imagefitness com new products prizes fitness tips and much more Access Panel Model No IMSB61502 IMSG61502 Serial No The serial number is found on a...

Страница 2: ...16 Part List 18 Exploded Drawing 19 Ordering Replacement Parts Back Cover Limited Warranty Back Cover The warning sign shown below must be posted on a wall or fence where it will be visible to all users of the hydrotherapy spa Whenever the spa is moved the sign must also be moved and reposted near the spa If the sign becomes lost or illegible call our toll free Customer Hot Line at 1 877 897 7493 ...

Страница 3: ...es can cause significant damage such as blistering of the shell surface and warping of the spa shell Any damage caused by sun exposure is not covered under the warranty 9 Do not bring any object into the hydrotherapy spa that could damage the spa shell 10 Never insert any object into any opening 11 Do not use breakable containers in or near the hydrotherapy spa 12 Do not sit on the spa cover or pl...

Страница 4: ...injury Pregnant women should consult with their physician before using the hydrotherapy spa Pregnant women should not use the spa if the water temperature is above 100 F the unborn child could be seriously harmed This is especially important during the first 90 days of the pregnancy 29 DANGER To reduce the risk of drowning Prolonged immersion in the hydrotherapy spa may cause hyperthermia The caus...

Страница 5: ...all users of the hydrotherapy spa can see and read it See POSTING THE WARNING SIGN on page 2 37 WARNING DECAL PLACEMENT Locate the decals shown below and familiarize yourself with the information on the decals WARNING Read all instructions before using the hydrotherapy spa ICON assumes no responsibility for personal injury or property damage sustained by or through the use of this product SAVE THE...

Страница 6: ...ed to feel your best For your benefit read this manual carefully before using the RENEW 615 If you have questions after reading the manual call our Customer Service Department toll free at 1 877 897 7493 Monday through Friday 6 a m until 6 p m Mountain Time excluding holidays To help us assist you please mention the product model number and serial number when calling The model number is IMSB61500 ...

Страница 7: ... spa provided that you leave access to the motor for service 9 Be sure to note any other considerations such as aesthetics or privacy concerns that may affect the safety or enjoyment of using the spa If you set up the hydrotherapy spa outside 1 Check local building codes concerning the use of outdoor spas 2 The spa should be located near a power source capable of suppling 240 volts AC power It mus...

Страница 8: ...metal metal water pipes or conduit within five feet of the spa 1 Before beginning assembly make sure that you have read and understand the information in the box above and on the previous two pages Remove the four indicated 1 4 x 1 1 2 Machine Screws 7 Remove the Long Access Panel 2 by sliding it down and then pulling the bottom away from the spa Be careful not to damage the spa shell Assembly Col...

Страница 9: ...en provided on the inside of the electronics package as a reference Under no circumstances should the spa be wired by someone other than a qualified electrician Before you have the spa wired make sure that it is in the desired position and that it can be serviced if needed 6 Pull down one of the straps on the Spa Cover 11 and hold the Buckle 30 against one of the cedar panels on the spa Note To po...

Страница 10: ...ater maintenance STARTING THE HYDROTHERAPY SPA You should always test the GFCI before using the hydrotherapy spa First turn on the spa by pressing the jet button on the console see USING THE CON TROLS on page 12 Once the spa is running press the GFCI test button The spa should shut off Press the reset button The spa should resume normal operation If the spa continues to run after the test button i...

Страница 11: ...nd close them F The two fixed jets are always on G An optional ozone generator can be purchased and installed to utilize the ozone jet Ozone provides a way to help sanitize the spa with minimal chemical treatment H The skimmer cleans the surface of the water I The temperature probe monitors water temperature J The underwater light can be used for night opera tion see USING THE CONTROLS on page 12 ...

Страница 12: ...t temperature Note To keep the filter and heat cycles from running the power to the spa must be turned off Light Button Turns the underwater light on and off Temperature Buttons Control the temperature setting of the water The temperature can be set between 80 F and 104 F The water heats at about 6 F per hour with the cover on Use a medical or other accu rate thermometer to check the temperature o...

Страница 13: ...ap solution do not use solvents The spa should always be clean and dry before being moved or stored MAINTAINING THE SPA COVER The spa cover should be cleaned monthly To clean the spa cover use water and a non abrasive cleaner on the entire cover Rinse the cover with a garden hose to remove any cleaner residue Dry the cover entirely Use a non silicone based vinyl conditioner on the cover after you ...

Страница 14: ...t testing and adjusting the pH CHANGING THE FILTER CYCLE The spa will filter the water every 12 hours The dura tion of the cycle can be adjusted to last 2 5 hours Press the temp up or temp down button on the con sole When the display begins to flash press the pump 1 button The display will read F2 To change the time press the temp up button until the desired time is reached Press the pump 1 button...

Страница 15: ...a 1 Drain the spa see DRAINING THE HYDROTHER APY SPA on the previous page and this page 2 Remove all remaining water from the spa shell Dry the spa shell with towels 3 Set the air control to the lowest setting Use a wet dry vacuum to pull any remaining water from the system To do this place the vacuum nozzle over each jet starting with the highest jet and fin ishing with the lowest jet 4 Set the a...

Страница 16: ... water to reach the set tempera ture b If you are using the hydrotherapy spa outdoors it may take longer for the water to heat See the chart below for the approximate heating time Air Temperature Heating Time 70 F 6 to 8 hours 50 F to 70 F 9 to 11 hours 30 F to 50 F 12 to 14 hours b If the water still has not heated after two days contact our customer service department 7 SYMPTOM THE WATER IS NOT ...

Страница 17: ...en the air control is turned counterclockwise simply turn the rims of the jets counterclockwise Turning the rims clockwise will close the jets 12 SYMPTOM THE CONSOLE DISPLAYS THE WORDS COOL OR ICE a This is a normal function of the spa no action is necessary The word COOL will appear in the display if the temperature of the water is more than 20 F cooler than the set temperature If this happens th...

Страница 18: ...rd 22 2 Nozzle Bushing 23 3 Medium Nozzle 24 4 1 4 Lock Washer 25 4 Corner Panel 26 5 Jet Housing 27 1 Drain Plug 28 1 Drain Plug O ring 29 4 Rubber Washer 30 8 Buckle 31 16 4 x 3 4 Screw 32 4 Flared Nozzle 33 1 Filter Cover O ring 34 1 Air Control Knob 35 1 Cover Ring 36 3 Nozzle Housing 37 4 Nozzle Retainer Ring 38 4 1 4 Washer 39 1 Rotator 40 1 Light Cover Red 41 1 Light Cover Blue 42 1 Diverte...

Страница 19: ...34 26 1 26 30 31 14 21 27 28 13 20 11 7 2 7 5 25 25 25 16 3 26 26 10 18 17 9 9 33 13 9 24 24 24 38 38 38 38 29 29 29 4 6 19 23 36 39 35 32 37 12 3 19 22 18 19 Exploded Drawing Model No IMSB61502 IMSG61502 R0201A ...

Страница 20: ...ollowing incidents any damage to the cedar surround or steel frame attributable to improper handling or freight damage damage resulting from improper winterization damage to the spa shell resulting from improper chemical treatment damage to the spa shell resulting from exposure to extreme temperatures or damage to the spa shell resulting from expo sure to direct sunlight and ultraviolet rays while...

Отзывы: