Error Messages
When working with the Ixpress system as a stand-alone unit the
following error messages in the Ixpress display ensure complete control
of image quality.
Each message is accompanied by a low key error sound:
"Image transfer error"
An error has occurred between the Ixpress camera back and Image Bank.
Please check the link cable and connectors.
"Camera body error"
An error has occurred between camera and Ixpress camera back.
Please check exposure cables, connectors, and batteries.
"Time out exposure error"
The camera back receives a time out signal while waiting for the
exposure to finish.
Please check that the exposure time is set correctly.
"Bad Exposure"
The camera back has performed a "wake-up" capture after having been
switched into "sleep" mode.
This capture should be deleted instantly.
User's Guide - Imacon Ixpress
English
The Ixpress Camera Back
29
Error Messages