Im-en Export Frijters Rijsbergen B.V LaserOP 3.0 Скачать руководство пользователя страница 7

7

3.2 

INFORMATION AND SAFETY REqUIREMENTS FOR  

 

 

CLASS 3B LASER DEVICES

3.3 

RESIDUAL RISkS

The laser classification and this Instruction Manual have been compiled 
in accordance with the harmonized European Standard EN IEC 60825-
1:2014.

The output power of this laser device is 100 mW at a laser beam wave 
length of 532 nm with a fully opened lens. 
The power definition is in conformity with the European Standard EN 
60825-1:2014 and amounts to 21 mW over 7 mm at a distance of 100 mm 
from the lens.

The following table shows the power values for given distances, in accor-
dance with EN 60825-1:2014 (NOHD).

In the Netherlands, the operator should comply with the requirements 
listed in sections 6.12, 6.26, and 6.27 of the ARBO-resolution. In Belgium, 
the user should consider the public health laws.

The residual risk of the LaserOp device is that eye damage may occur after 
looking straight into the laser beam, with or without optical devices.
The operator should ensure that neither himself or any 
exposed persons could look straight into the laser beam, which could lead 
to eye damage or even blindness. 

> If necessary, place warning signs up to a distance of 1,016 metres (0.65 
miles) for any possibly exposed persons, even if such persons would be 
trespassing on “forbidden premises”.

> NEVER point the laser beam towards airplanes, boats, moving vehicles, 
or any other object for which the light might be hazardous.

Содержание LaserOP 3.0

Страница 1: ...Instruction manual To scare birds with a laser beam 2017 Im en Export Frijters Rijsbergen B V Translated Instruction Manual Version 2 1 2017...

Страница 2: ...ined qualified operator user 6 3 2 Information and safety requirements for class 3b laser devices 7 3 3 Residual risks 8 4 USE AND OPERATION 9 4 1 Inserting the batteries 9 4 2 Powering up the LaserOp...

Страница 3: ...the Operating and Safety Instructions it contains at any time Operating the LaserOp is ONLY allowed if this Instruction Manual is thoroughly known and understood The operator should respect all Usage...

Страница 4: ...uccessful in many different situations scaring away all kinds of nuisance causing birds It is efficient on farm fields horticulture plots cereal storing facilities cattle stables country estates landf...

Страница 5: ...2 3 LaserOp case and contents 2 4 LaserOp device description 5...

Страница 6: ...ioning setup operating cleaning and servicing of the LaserOp can only be performed by specially trained personnel A guaran teed internal certification authorisation at the operator s organisation is n...

Страница 7: ...HD In the Netherlands the operator should comply with the requirements listed in sections 6 12 6 26 and 6 27 of the ARBO resolution In Belgium the user should consider the public health laws The resid...

Страница 8: ...er beam when you are at less than 1 016 metres 0 65 miles from the device as this would cause serious eye damage If you accidentally do look into the beam seek immediate medical attention in order to...

Страница 9: ...could be within the reach of the laser beam 1 Power up the LaserOp with the ON OFF key switch located in the middle of the end cap 2 Next push the main switch the control light turns on 3 As soon as...

Страница 10: ...wards the birds or just above them Normally the birds will immediately flee to a nearby hiding place follow them with the beam to scare them away from their hiding place If this is regularly done the...

Страница 11: ...11...

Страница 12: ...of the battery compartment the LaserOp may never be opened by the user The device should be stored in a dry and dust free area at constant ambient temperature Getting started The LaserOp has the IP 52...

Страница 13: ...ijsbergen B V reserves the right to change the above men tioned technical data as a result of the ongoing innovative development of the LaserOp without prior notification Furthermore the technical dat...

Страница 14: ...6 FAULTS OVERVIEW 14...

Страница 15: ...rOp Year Built 2017 Applied EC directive EMC Directive 2014 30 EU Applied Standards EN IEC 60529 1992 A1 2000 Degrees of protection provided by enclosures IP Code EN IEC 60825 1 2014 Safety of laser p...

Страница 16: ...Im en Export Frijters Rijsbergen B V Smokstraat 2 4891 ZK Rijsbergen NL The Netherlands Phone 0031 0 6 51 35 34 47 E mail info ketrop com 8 CONTACT DETAILS OF MANUFACTURER 16...

Отзывы: