![Im-en Export Frijters Rijsbergen B.V LaserOP 3.0 Скачать руководство пользователя страница 7](http://html1.mh-extra.com/html/im-en-export-frijters-rijsbergen-b-v/laserop-3-0/laserop-3-0_instruction-manual_2044805007.webp)
7
3.2
INFORMATION AND SAFETY REqUIREMENTS FOR
CLASS 3B LASER DEVICES
3.3
RESIDUAL RISkS
The laser classification and this Instruction Manual have been compiled
in accordance with the harmonized European Standard EN IEC 60825-
1:2014.
The output power of this laser device is 100 mW at a laser beam wave
length of 532 nm with a fully opened lens.
The power definition is in conformity with the European Standard EN
60825-1:2014 and amounts to 21 mW over 7 mm at a distance of 100 mm
from the lens.
The following table shows the power values for given distances, in accor-
dance with EN 60825-1:2014 (NOHD).
In the Netherlands, the operator should comply with the requirements
listed in sections 6.12, 6.26, and 6.27 of the ARBO-resolution. In Belgium,
the user should consider the public health laws.
The residual risk of the LaserOp device is that eye damage may occur after
looking straight into the laser beam, with or without optical devices.
The operator should ensure that neither himself or any
exposed persons could look straight into the laser beam, which could lead
to eye damage or even blindness.
> If necessary, place warning signs up to a distance of 1,016 metres (0.65
miles) for any possibly exposed persons, even if such persons would be
trespassing on “forbidden premises”.
> NEVER point the laser beam towards airplanes, boats, moving vehicles,
or any other object for which the light might be hazardous.