background image

1.0m

1.0m

1.0m

90˚ Bend = 1.0m

1.0m

2.0m

1.0m

1.0m

90˚ Bend = 1.0m

3.0m

1.0m

In-line Motor - this needs to 
run off a separate activation 
switch to the range hood

External Vent

External Vent

RANGE HOODS

HOOD DUCTING GUIDE

Here are some important points to consider when choosing and/or installing a range hood:

• 

An externally ducted range hood will generally outperform a recirculating range hood.

• 

We discourage the use of flexible ducting as this has a significant negative impact on airflow and noise due to turbulence 

• 

caused by the ribs. Instead consider using semi-rigid or rigid duct.

• 

Avoid using a narrower duct than specified as this will reduce airflow; the best performance is obtained when the range hood is 
installed with a short duct with minimal bends.

• 

To determine the required clearance between the cooktop and the range hood always consult the installation manual for both 
the range hood and cooktop. The required clearance is the greater of the distance specified in either manual (and a minimum of 
600mm between the highest point of the highest burner for gas cooktops).

• 

Five metres is the recommended maximum length for ducting (see diagram 1.). When the ducting exceeds five metres in length 
the installation of a TD500 or TD350 in-line motor is required, which must be placed one metre from the external vent (see 
diagram 2.).

Diagram 1.

Diagram 2.

Содержание eurolinx H15/90/S

Страница 1: ...H15 90 S H15 90 W 230Vac 50Hz ...

Страница 2: ......

Страница 3: ... 150 125 reduction is provided with the hood This pipe must not under any circumstances be connected to cooker boiler or burner exhaust pipes etc Filtering Fig 3 The fumes pass through the carbon filters to be purified and recycled into the kitchen through a pipe connected to the outlet of the hood up to the hole in the top of the cabinet This hole must be free and communicating with the kitchen I...

Страница 4: ...f therefore it must be carefully kept and ALWAYS accompany it even in case of its assignment to another owner or user or in case the cooker hood is moved to another installation plant Any eventual adjustment to the electrical system which may be necessary to install the cooker hood must be carried out only by competent people Any repair carried out by no competent people may cause damages For any ...

Страница 5: ......

Страница 6: ...id duct Avoid using a narrower duct than specified as this will reduce airflow the best performance is obtained when the range hood is installed with a short duct with minimal bends To determine the required clearance between the cooktop and the range hood always consult the installation manual for both the range hood and cooktop The required clearance is the greater of the distance specified in e...

Страница 7: ...NOTES ...

Страница 8: ...COD 395 409 1 ...

Отзывы: