Pressure Adjustment
First turn the gas off to the appliance. Remove the sealing screw from the regulator’s test point at the
rear of the appliance and place the hose of the Manometer onto it. Turn the gas on to the appliance and
light the Wok Burner and Small Burner at maximum setting. Check the pressure and adjust at the regulator
if necessary to the setting in the table on the last page or the Data plate. For ULPG Gas adjust at the
regulator on the cylinder – Turn regulator adjusting screw clockwise increases pressure whilst
anti-clockwise decreases pressure. Refit the test point sealing screw when finished.
Electrical Equipment and Components
Electrical componentry is primarily located below the hob surface. Removal of the hob is straightforward
by removing the control knobs, trivets, the burner caps and burner head assemblies and skirts. Using
a flat bladed screwdriver remove the five screws, one in each corner of the hotplates left and right spillage
bowls and one centrally located at the rear of the centre spillage bowl. Than lift the hob upwards.
Replacement is a reversal of the above procedure. Care must be taken to ensure that no damage occurs
to the spark ignition leads or the igniters. The electronic ignition pack is easily accessible for service or
replacement below the hob centrally at the rear.
ALWAYS ENSURE THAT THE POWER SUPPLY IS DISCONNECTED BEFORE SERVICING APPLIANCE
Gas Controls And Gas Manifold
Removal of the gas manifold is accomplished by removing the control knobs, the trivets, the
burner caps and burner head assemblies and skirts. Using a flat bladed screwdriver remove the five
screws, one in each corner of the hotplates left and right spillage bowls and one centrally located at the
rear of the centre spillage bowl. Care must be taken to ensure that no damage occurs to the spark ignition
leads, igniters or thermocouples (if fitted). Disconnect all ancillary gas piping. Remove the two securing
screws from the positioning brackets at the front and also the securing bracket near the gas inlet point to
the burner compartment. The gas manifold may then be extracted. Replacement is a reversal of the above
procedure.
ALWAYS ENSURE THAT THE GAS CONNECTION IS DISCONNECTED BEFORE SERVICING APPLIANCE
Conversion
If the appliance is to be used with another gas type, either ULPG Gas or Natural Gas, it must be converted
by an Authorised Person. Contact Eurolinx Pty Ltd or their unathorized agent for details. For Natural and
ULPG Gas Injector Sizes and Mj/H refer to tables on pages 21 & 22. The table on page 22 shows the
appropriate injector sizes for either ULPG Gas or Natural Gas.
NOTE
After conversion check the GAS PRESSURE and IGNITER OPERATION for the burners. If the hotplate
cooker cannot be adjusted to perform correctly, or if there is excessive flame discolouration, yellow tipping
or excessive noise contact ILVE or their authorised agent for advice. It is also recommended
that this appliance be serviced at 12 months minimum intervals or sooner as required. Please also ensure
that the duplicate data plate supplied be attached to the appliance or in an accessible place such as a
cupboard for future reference.
IMPORTANT:
Verify periodically the gas connection pipe and replace it as soon as any irregularity is present.
IMPORTANT:
Correct positioning of the brass flame distributor is very important. For this purpose, ensure that
the flame distributor tooth coincides with the notch on the aluminum base. To keep the flame
distributor covers new, you are advised to remove them before lighting the flame.