background image

16

MOD.

Ø EXIT HOLE  

(mm)

SUCTION 

(m

3/

h)

AG60

150

1000

AG70

150

1000

AG90

150

1000

AG100

150

1000

AG120

150

1000

AG150

150

1000

INSTALLATION

ø150 - 200 mm

600 - 700 -  - 900 - 1000 - 1200 - 1500 mm

500 mm  |

Min 710 mm | Max 1070 mm

350 mm 

ø150 - 200 mm

ø150 - 200 mm

700 - 760 - 911 - 1000 - 1216 - 1511 mm

600 mm  |

Min 810mm | Max 1130mm

440 mm 

 220/240 V

50 Hz 

 340 mm

Содержание AG100

Страница 1: ...HOODS AG AG60 AG70 AG90 AG100 AG120 AG150 USER Use and Maintenance INSTALLER Installation manual cod EI33960380000EN 08 2021 EN ...

Страница 2: ......

Страница 3: ...L INFORMATION IMPORTANT SAFETY WARNING INSTRUCTIONS FOR USE CLEANING AND MAINTENANCE PERIODS OF INACTIVITY ORDINARY MAINTENANCE replacement of the spotlight IMPORTANT SAFETY WARNINGS INSTALLATION IMPORTANT SAFETY WARNINGS INSTALLATION INSTALLER 14 31 ...

Страница 4: ...l guide you through starting using the hood quickly and without difficulty We therefore recommend that you read it carefully before use and that you store it carefully for futurereference We remain at your full disposal for any further information that you may require or if you have any problems in understanding any contents of this booklet ILVE S p a Via Antoniana 100 35011 Campodarsego PD Italy ...

Страница 5: ... tuation that might cause injuries or death Read the instruction manual Useful advice and information Reference to another chapter The Manufacturer reserves the right to make improving modifications to the equipment or accessories at any time Partial reproduction without th Manufacturer s authorization is forbidden The measure ments given are indicative and not binding ICON ATTENTION ...

Страница 6: ...on genu ine spare parts supplied by ILVE S p a This appliance can be used by children from the age of 8 and by people with reduced physical sensory or men tal abilities or with a lack of experience and knowledge if they are under adequate supervision or if they have been instructed to use the appliance in safely and if they realize the related dangers The equipment is only intended for the extract...

Страница 7: ...t e g gloves safety footwear etc after the surfaces of the hood have COOLED DOWN always wear appropriate personal protective equipment i e gloves safety footwear etc Failure to follow the instructions or the use of unsuitable cleaning devices may pose a risk of fire and or damage to the hood or the surrounding objects so the Manufacturer couldn t be held responsible egular daily cleaning and maint...

Страница 8: ...The hood must be switched on at least a couple of minutes before starting to cook to promote the suction of fumes and steam After finishing cooking leave the hood in operation for an extra few minutes in this case it may be appropriate to activate the Timer function which automatically switches the hood off after 10 minutes The page that follows shows how to use the control panel What speed should...

Страница 9: ...sts the motor at full speed for 5 minutes and after that automaticalty returns to the third speed TIMER FUNCTION By pressing the TIMER push button while the hood is working the clock symbol will start flashing Once the timer is set the hood will continue working for about 10 minutes and then it will automatically switch off The timer can be switched off at any moment by pressing its push button In...

Страница 10: ...trol connected to the light enables the red led light for half a second Coupling with the remote control of the hood When enabling the hood in the tirsi 7 seconds push the ON OFF button on the remote control for two seconds In this way the remote contrai will be coupled and activated After the tirsi 7 seconds the programming of the hood will be tinished and the coupling will be protected tram exte...

Страница 11: ... muriatic or sulphuric acid abrasive or sharp tools e g abrasive sponges scrapers steel brushes etc water sprays The INSIDE and the OUTSIDE of the hood should be cleaned solely by using a damp cloth with little neutral soap It is also possible to use a steel specific cleanser paying attention to the instructions written on the canister or bottle To conclude the cleaning operation rinse using a cle...

Страница 12: ...lease note that the maximum temperature is 70 C 158 F higher temperature can cause darkening in the metal please note that this DOES NOT impair the operation of the filter For their removal see Fig 5 ACTIVE CARBON FILTERS These filters cannot be washed or regenerated and should therefore be replaced every 3 to 4 months depending on the hood usage Damp environments high temperature soiled anti grea...

Страница 13: ...Vaseline oil to all stainless steel surfaces At first use accurately clean the equipment reconnect the power supply ALWAYS MAKE SURE THAT THE APPLIANCE IS DISCONNECTED FROM THE NETWORK 1 2 Remove the metal filters 3 Push the spotlight from the inside to the outside 4 disconnect and replace the entire spotlight PROCEDURE TO FOLLOW 2 1 Fig 5 ORDINARY MAINTENANCE replacement of the spotlight ...

Страница 14: ... power supply cord is too short have a qualified electrician install an outlet near the appliance WARNING TO REDUCE THE RISK OF FIRE USE ONLY METAL DUCTWORK WARNING TO PROVIDE PROTECTION AGAINST ELECTRIC SHOCK CONNECT TO PROPERLY GROUNDED OUTLETS ONLY WARNING there shall be adequate ventilation of the room when the range hood is used at the same time as ap pliances burning gas or other fuels not a...

Страница 15: ...be replaced by the manufacturer its ervice agent or similarly qualified persons in order to avoid a hazard Before installing the equipment carefully read the safety instructions page 6 and the indications provided from page 14 IMPORTANT SAFETY WARNINGS ...

Страница 16: ...90 150 1000 AG100 150 1000 AG120 150 1000 AG150 150 1000 INSTALLATION ø150 200 mm 600 700 900 1000 1200 1500 mm 5 0 0 m m Min 710 mm Max 1070 mm 350 mm ø150 200 mm ø150 200 mm 700 760 911 1000 1216 1511 mm 6 0 0 m m Min 810mm Max 1130mm 440 mm 220 240 V 50 Hz 340 mm ...

Страница 17: ...17 INSTALLER ø8 mm UTENSILI NECESSARI CONTENUTO IMBALLO ø 05 16 40 mm 137 64 45 mm 149 64 x2 x4 10 mm 025 64 x 4 INSTALLATION NECESSARY TOOLS PACKAGE CONTENT ...

Страница 18: ...ion on other types of walls consider alternative fastening systems taking into a count the strength of the wall itself and the wei ght of the hood INSTALLATION STEP 1 x2 2 3 1 1000 mm 45 mm 149 64 ø8 mm ø 05 16 1000 MM 40 23 64 min 1000 MM 40 23 64 min 1000 MM 4023 64 min 1000 MM 4023 64 min 1000 mm 1000 mm ...

Страница 19: ...19 INSTALLER INSTALLATION STEP 2 STEP 3 2 1 1000 MM 4023 64 min 1000 MM 4023 64 min ...

Страница 20: ...20 INSTALLATION STEP 4 STEP 5 1 2 1 ø8 mm ø 05 16 1000 MM 40 23 64 min 1000 MM 40 23 64 min ...

Страница 21: ...21 INSTALLER INSTALLATION STEP 6 STEP 7 1 3 4 2 2 3 1 ø8 mm ø 05 16 40 mm 137 64 ...

Страница 22: ...22 INSTALLATION STEP 8 STEP 9 ...

Страница 23: ...23 INSTALLER INSTALLATION STEP 10 STEP 11 2 1 150 mm 5 29 32 min 3 2 1 3 4 ...

Страница 24: ...24 INSTALLATION STEP 12 STEP 13 2 3 4 1 ø8 mm ø 05 16 40 mm 137 64 ...

Страница 25: ...25 INSTALLER INSTALLATION STEP 14 1 2 STEP 15 ...

Страница 26: ...26 INSTALLATION STEP 16 STEP 17 2 1 ...

Страница 27: ...ys compare the system data with that printed on the data plate check all the components for integrity and functionality in case of fault stop the installation and contact the distributor Do no connect the product to the power main before any other step of the installation is completed Any interventions tampering or modifications not expressly authorised not complying with the content of this manua...

Страница 28: ...c connection socket must be easy to reach even after installation of the equipment Should this not be the case a general switch must be installed in order to disconnect the hood from the power supply in case of need The maximum weight of any objects placed on top of the hood or attached to the same should not exceed 2 kg 4 4 lb The air must not be discharged into a flue that is used for exhausting...

Страница 29: ...T USE PREPARATION After the hood installation please remove the protective film and carefully clean the external surface Fig 2 Please note that the use of acid based cleansers could damage the hood surface so use a neutral or a steel specific cleanser only All packaging and the protective film must be disposed of in accordance with the regulations of the country of use Always make sure that nothin...

Страница 30: ...lace safety regu lations The equipment must only be installed by responsible and experienced adults without physical impairment and in perfect psychological and physical con dition During installation anyone and any objects not involved in the assembly operations must be kept away from the area Before starting the assembly operations make sure that all the necessary tools are available and in good...

Страница 31: ...rer from all responsibility Make sure that the flue is in perfect working order and that a square concrete or round metal static wind break ventilation tower with useful output section not less than double the diameter of the flue UNI 7129 is instal led at the top of the flue itself Comply with all air discharge regulations The drain chimney of the building should be dedicated to the hood only so ...

Страница 32: ......

Отзывы: