Page 5 of 16
Setup
Ilumipod LL User Manual Rev. 1
3. Setup
AC Power
The Ilumipod LL has an auto-ranging power supply, and it can work with an input voltage range of 100 to
240 VAC, 50/60 Hz.
To determine the product’s power requirements (circuit breaker, power outlet, and wiring), use the current
value listed on the label affixed to the product’s back panel, or refer to the product’s specifications chart.
The listed current rating indicates the product’s average current draw under normal conditions.
AC Plug
The Ilumipod LL comes with a bare-ended power input cord. Use the table below to wire a plug.
DMX Linking
The Ilumipod LL will work with a DMX controller using a standard DMX serial connection. A DMX Primer is
available from
.
DMX Connection
The Ilumiline Power and Data Interface (sold separately) provides a DMX-512 connection using bare-ended
IP67-rated signal cable. This cable comes connected to the product.
•
Always connect the product to a protected circuit (a circuit breaker or fuse). Make sure
the product has an appropriate electrical ground to avoid the risk of electrocution or fire.
•
To eliminate unnecessary wear and improve its lifespan, during periods of non-use
completely disconnect the product from power via breaker or by unplugging it.
•
Use only proprietary IP67 waterproof cables and secure unused ports with attached
IP67 covers.
Never connect the product to a rheostat (variable resistor) or dimmer circuit, even if the
rheostat or dimmer channel serves only as a 0 to 100% switch.
Connection
Wire (U.S.)
Wire (Europe)
Screw Color
AC Live
Black
Brown
Yellow or Brass
AC Neutral
White
Blue
Silver
AC Ground
Green/Yellow
Green/Yellow
Green
1. Ground
2. Data -
3. Data +
1. Ground (black clip)
2. Data -
(green clip)
3. Data +
(red clip)
DMX Output
Signal Connector